Shop
Yokogawa AQ2211 – 3 Slot Frame Controller
- 3 slot Mainframe
- Easy-to-view color display
- USB port for data storage
- Measurement module “hot-swapping” capability
- Remote monitoring and measurement through a LAN
Yokogawa AQ6151B – Optical Wavelength Meter
- High wavelength accuracy: ±0.2 ppm
- Wavelength range (3 types): 900-1700nm, 1200-1700nm, 1270-1650nm
- Measurement time of 0.2 seconds or less
- Up to 1024 wavelengths can be measured at once
- Single wavelength type and multi wavelength type
- Support modulated light and filter measurement
Yokogawa AQ2212 – 9 Slot Frame Controller
- 9 Slot Mainframe
- Easy-to-view color display
- USB port for data storage
- Measurement module “hot-swapping” capability
- Remote monitoring and measurement through a LAN
Yokogawa AQ2200 – Modular Manufacturing Test Systems
- 3 or 9 slot Mainframe
- Hot-swappable modules
- A broad lineup of measurement modules
- Grid tunable laser source, Optical power meter, Optical attenuator, Optical switch, etc.
- Macro Programming Function; a convenient solution for automated measurements eliminating need for an external PC controller.
- Remote interfaces : GP-IB, Ethernet, and USB
- Multi-user function
- Remote Viewer Software
- Stability / Logging Function
Yokogawa AQ2200-131/132 – Grid Light Source Modules
- Frequency (Wavelength): C-band, L-band
- High-stability output level: ± 0.03dB
- High-stability frequency(wavelength): ± 0.3GHz (± 2.4pm)
- Output level: +9dBm or more
- High SMSR: 45dB
Yokogawa AQ2200-215 – High Power Sensor Modules
- High Power Measurement: +30dBm
- High-Speed Sampling: 10,000 points per second
- Various Optical Connectors: FC/SC/MU/LC
- Fully Configurable: Create the desired measurement system by combining AQ2200 Series modules with Yokogawa optical communications measuring instruments
Yokogawa AQ2200-222 – Dual Sensor Modules
- Ideal for powerful yet compact systems.
- Wide wavelength range: 800 to 1700 nm
- Wide power range: -90 to +15 dBm
- High-speed measurement: 100 µs (minimum sampling period)
- Optical connector compatibility: FC, SC, MU, and LC
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems.
Yokogawa AQ2200-312 – Optical Attenuator Module
- Wide attenuation range:
- 0 to 60 dB (SM version)
- 0 to 45 dB (MM version)
- Wide wavelength range:
- 1200 to 1700 nm(SM version)
- 800 to 1370 nm (MM version)
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Low insertion loss: 1.0 dB (typical)
- Low polarization dependence loss: 0.1 dBp-p or less
- Monitor output (optional)
- Configure the desired measurement system by combining AQ2200 Series modules with Yokogawa optical communications measuring instruments
Yokogawa AQ2200-332 – Optical Attenuator Module
- Compact: The AQ2200-332 features an optical variable attenuator and an optical power meter for monitoring the optical output power in a one-slot module. Ideal for bit error testing
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Attenuation accuracy: within ±0.1 dB
- With the output monitoring function, the AQ2200-332 allows direct setup of optical power at the output terminals
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-411 – Optical Switch Module
- Compact: Optical switches of 1 x 4 or 1 x 8 port configuration in a one-slot size module
- Compatible with SMF (core diameter of 10 µm) or MMF (core diameter of 62.5 µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-412 – Optical Switch Module
- Compact: Optical switches of 1 x 16 port configuration in a two-slot size module
- Compatible with SMF(10/125µm) or MMF(50/125µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-421 – Optical Switch Module
- Compact: Optical switches of 1 x 2 or 2 x 2 port configuration in a one-slot size module
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-642 – Transceiver I/F Module
- Support 10G optical transceivers
- XFP, SFP+, XENPAK
- Power supply and power current monitoring
- Equipped with current limiter
- I2C/MDIO interface
- Signal Control
- User can define the signal names
- Voltage monitoring of status signals
- Threshold adjustment for High/Low decision
- Resistance monitoring for APS SET
Yokogawa AQ4280 – Portable Optical Light Sources
- Three-wavelengths to address telecom service, plus additional wavelength for maintenance channel.
AQ4280A ; 1310/1550nm
AQ4280B ; 1310/1490/1550nm
AQ4280C ; 1310/1550,1490/1625nm (2 ports) - Auto switching of measurement wavelength
Yokogawa AQ6373B – Visible Wavelength Optical Spectrum Analyzers
- Wavelength range: 350 to 1200nm
- Wavelength accuracy: ±0.05 nm
- Wavelength resolution: 0.02 to 10 nm and 0.01nm (400 to 470nm)
- Max safe input power: +20 dBm
- Level sensitivity: -80 dBm
- Dynamic range: ≧60dB
- Single-mode, Multimode, and Large-core fibers
- Built-in optical alignment source
- Wavelength calibration with an external reference source
- Various analysis functions including the Color analysis function for VIS
Yokogawa AQ6374 – Wide Range Optical Spectrum Analyzers
- Wavelength range: 350 to 1750nm
- High wavelength accuracy: ±0.05nm
- High wavelength resolution: 0.05 to 10 nm
- Wide dynamic range: 60dB (peak ±1.0nm)
- Wide level range: +20 to -80dBm
- Fast measurement: 0.5 sec. (100nm span)
- 8 wavelength resolution settings: 0.05 to 10 nm
- wide measurable level range is from−80 to +20 dBm
- ±0.05 nm wavelength accuracy can be maintained by the calibration
- Fast Measurement 0.5 s for 100 nm span (with sensitivity set to NORM_AUTO)