Showing 833–848 of 941 results

Weiss Technik Reach-In Environmental Test Chambers

Weiss Technik offers many reach-in chamber options, including those specific to noxious gas testing, temperature and humidity, extreme hot and cold testing, and more.

Weiss Technik Specialty Environmental Test Chamber Solutions

Weiss Technik offers a range of custom test chamber solutions, including those designed to test batteries, microwave systems, noxious gas, plant growth, clean rooms, emissions and more.

Weiss Technik Thermal Shock Environmental Test Chambers

The Weiss Technik Thermal Shock environmental test chambers provide stress screening of products to help find defects in electrical assemblies and other components. With two separately controlled hot and cold zones, thermal shock chambers provide rapid temperature changes. Meets many MIL-STD testing requirements. A wide selection of models are available to fit your exact testing requirements. Models include vertical, horizontal and liquid.

Weiss Technik Drive-In & Walk-In Environmental Chambers

Weiss Technik offers many drive-in & walk-in environmental chamber models, including those designed for altitude testing, stability testing, as well as chambers that integrate with Dynamometers. Pre-engineered and custom solutions are available.

Yokogawa AQ6360 – Telecom Optical Spectrum Analyzers

  • Wavelength range: 1200 to 1650 nm
  • Wavelength resolution: 0.1 to 2 nm
  • High wavelength accuracy: ±0.02 nm
  • High dynamic range: 55 dB
  • Wide measurement range: +20 to −80 dBm

Yokogawa AQ6370D – Telecom Optical Spectrum Analyzers

Notice: This product has been discontinued.
Replaced by: AQ6370E
  • Wavelength range: 600 to 1700nm
  • Built-in calibration source
  • High wavelength accuracy: ±0.01nm
  • High wavelength resolution: 0.02nm
  • Wide dynamic range: 78dB typ.
  • Wide level range: +20 to -90dBm
  • Fast measurement: 0.2 sec. (100nm span)
  • Applicable to single-mode and multi-mode fibers

Yokogawa AQ6370E – Telecom Optical Spectrum Analyzers

  • Wavelength Range: 600 nm to 1700 nm
  • Wavelength Accuracy: ±0.008 nm (typical)
  • Wavelength Resolution: 0.02 nm
  • Close-in Dynamic Range: 78 dB (typical)
  • Level Range: +20 to -90 dBm
  • Up to 2x faster measurement with SMSR mode
  • Sharper spectrum measurement with HCDR mode
  • Large touchscreen LCD for easy operation and data visualization

Yokogawa WT5000 – Precision Power Analyzers

  • Sample Rate: 10 MS/s
  • Power Bandwidth: 1 MHz
  • Resolution: 18 bit
  • Elements: 1-7
  • Accuracy: 0.03%
  • 10.1″ touchscreen

Yokogawa 2553A – Precision DC Calibrator

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • High resolution: 5.5 digits ±120000 count output resolution
  • DC Voltage: ±10 mV to ±30 V
  • DC Current: ±1 mA to ±100 mA
  • Voltage accuracy: +/- 75 ppm
  • Current accuracy: +/- 120 ppm
  • Temperature calibration: 10 types of thermocouples including K, T, E, and J types
  • User-defined thermocouple and RTD (PT1000) calibration: Generates various types of thermocouple and RTD by extrapolating the relation between voltage and temperature

Yokogawa LS3300 – AC Power Calibrator

  • High Accuracy:
    • AC Voltage: ±350 ppm
    • AC Current: ±450 ppm
    • AC Power: ±450 ppm
  • Phase Accuracy: ±0.03Ëš at 50/60 Hz
  • High Stability:
    • AC voltage: ±50 ppm/h
    • AC current: ±50 ppm/h
    • AC power: ±100 ppm/h
  • Wide Generation Range:
    • AC voltage: 10 mV to 1250 V
    • AC current: 0.3 mA to 62.5 A
    • Frequency: 40 to 1200 Hz

Yokogawa 2558A – Precision AC Standard

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • 6 voltage ranges (100 m/1/10/100/300/1000 V)
  • 4 current ranges (100 m/1/10/50 A)
  • Sweep (Voltage/Current/Frequency)
  • Output Divider: Linearity tests can be simply performed by dividing the output into steps. For example, a setting of 4 will generate steps of 25, 50, 75 and 100% of the set output value.
  • % Deviation readout
  • Common current output terminals: The same output terminals are used for all current ranges. Test times are therefore reduced by avoiding the need to change the wiring for meters which have different ranges.
  • Wide frequency range-: 40 to 1000 Hz (Frequency accuracy : ±50 ppm)

Yokogawa 2560A – Precision DC Calibrator

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • High resolution: 5.5 digits ±120000 count output resolution
  • Accuracy:
    • DC voltage: ±50 ppm
    • DC current: ±70 ppm
  • Resolution:
    • 5.5 digits, ±120000 count display
    • 6.5 digits, ±1200000 count display – high res.
  • Direct readout of the deviation
  • Digital display of output
  • Output Divider
  • Sweep: With a flick of a switch, the output can be swept within the source range with sweep times of 8, 16, 32 or 64 seconds.
  • High stability
    • DC voltage: ±10 ppm/h
    • DC current: ±20 ppm/h

Yokogawa 30032A – Clamp-on Tester

  • Leakage current measurement range from 3mA to 60A
  • Diameter of measurable conductor: 40 mm max.
  • Easier and clear display

Yokogawa AQ1100 – Multi-function Optical Loss Test Sets

  • 5.7 inch color LCD for easy viewing
  • Multi-core fiber measurement with a pair set
  • Optional PING Test function and Visible light Source
  • Optical Power Meter Selections
    • Standard: +10 to -70dBm
    • High power: +27 to -50dBm
    • PON : 1490/1550nm Parallel measurement
  • Light Sources (3 models)
    • SM1310/1550nm
    • SM1310/1550/1625nmMM850/1300nm and SM1310

Yokogawa AQ2170/2170H – Portable Optical Power Meters

  • AQ2170 – +10 dBm max. power (Standard)
  • AQ2170H – +26 dBm max. power (High Power)
  • Up to 7 working wavelengths
  • Compact and lightweight
  • Versatile data storage and transfer large memory capacity stores up to 999 measurement results
  • Auto switching of measurement wavelength

Yokogawa AQ2180/2180H – Portable Optical Power Meters

  • AQ2180 – +10 dBm max. power (Standard)
  • AQ2180H – +26 dBm max. power (High Power)
  • Up to 7 working wavelengths
  • Compact and lightweight
  • Versatile data storage and transfer large memory capacity stores up to 999 measurement results
  • Auto switching of measurement wavelength