Showing 841–864 of 941 results

Yokogawa 2553A – Precision DC Calibrator

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • High resolution: 5.5 digits ±120000 count output resolution
  • DC Voltage: ±10 mV to ±30 V
  • DC Current: ±1 mA to ±100 mA
  • Voltage accuracy: +/- 75 ppm
  • Current accuracy: +/- 120 ppm
  • Temperature calibration: 10 types of thermocouples including K, T, E, and J types
  • User-defined thermocouple and RTD (PT1000) calibration: Generates various types of thermocouple and RTD by extrapolating the relation between voltage and temperature

Yokogawa LS3300 – AC Power Calibrator

  • High Accuracy:
    • AC Voltage: ±350 ppm
    • AC Current: ±450 ppm
    • AC Power: ±450 ppm
  • Phase Accuracy: ±0.03Ëš at 50/60 Hz
  • High Stability:
    • AC voltage: ±50 ppm/h
    • AC current: ±50 ppm/h
    • AC power: ±100 ppm/h
  • Wide Generation Range:
    • AC voltage: 10 mV to 1250 V
    • AC current: 0.3 mA to 62.5 A
    • Frequency: 40 to 1200 Hz

Yokogawa 2558A – Precision AC Standard

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • 6 voltage ranges (100 m/1/10/100/300/1000 V)
  • 4 current ranges (100 m/1/10/50 A)
  • Sweep (Voltage/Current/Frequency)
  • Output Divider: Linearity tests can be simply performed by dividing the output into steps. For example, a setting of 4 will generate steps of 25, 50, 75 and 100% of the set output value.
  • % Deviation readout
  • Common current output terminals: The same output terminals are used for all current ranges. Test times are therefore reduced by avoiding the need to change the wiring for meters which have different ranges.
  • Wide frequency range-: 40 to 1000 Hz (Frequency accuracy : ±50 ppm)

Yokogawa 2560A – Precision DC Calibrator

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • High resolution: 5.5 digits ±120000 count output resolution
  • Accuracy:
    • DC voltage: ±50 ppm
    • DC current: ±70 ppm
  • Resolution:
    • 5.5 digits, ±120000 count display
    • 6.5 digits, ±1200000 count display – high res.
  • Direct readout of the deviation
  • Digital display of output
  • Output Divider
  • Sweep: With a flick of a switch, the output can be swept within the source range with sweep times of 8, 16, 32 or 64 seconds.
  • High stability
    • DC voltage: ±10 ppm/h
    • DC current: ±20 ppm/h

Yokogawa 30032A – Clamp-on Tester

  • Leakage current measurement range from 3mA to 60A
  • Diameter of measurable conductor: 40 mm max.
  • Easier and clear display

Yokogawa AQ1100 – Multi-function Optical Loss Test Sets

  • 5.7 inch color LCD for easy viewing
  • Multi-core fiber measurement with a pair set
  • Optional PING Test function and Visible light Source
  • Optical Power Meter Selections
    • Standard: +10 to -70dBm
    • High power: +27 to -50dBm
    • PON : 1490/1550nm Parallel measurement
  • Light Sources (3 models)
    • SM1310/1550nm
    • SM1310/1550/1625nmMM850/1300nm and SM1310

Yokogawa AQ2170/2170H – Portable Optical Power Meters

  • AQ2170 – +10 dBm max. power (Standard)
  • AQ2170H – +26 dBm max. power (High Power)
  • Up to 7 working wavelengths
  • Compact and lightweight
  • Versatile data storage and transfer large memory capacity stores up to 999 measurement results
  • Auto switching of measurement wavelength

Yokogawa AQ2180/2180H – Portable Optical Power Meters

  • AQ2180 – +10 dBm max. power (Standard)
  • AQ2180H – +26 dBm max. power (High Power)
  • Up to 7 working wavelengths
  • Compact and lightweight
  • Versatile data storage and transfer large memory capacity stores up to 999 measurement results
  • Auto switching of measurement wavelength

Yokogawa AQ2211 – 3 Slot Frame Controller

  • 3 slot Mainframe
  • Easy-to-view color display
  • USB port for data storage
  • Measurement module “hot-swapping” capability
  • Remote monitoring and measurement through a LAN

Yokogawa AQ6151B – Optical Wavelength Meter

  • High wavelength accuracy: ±0.2 ppm
  • Wavelength range (3 types): 900-1700nm, 1200-1700nm, 1270-1650nm
  • Measurement time of 0.2 seconds or less
  • Up to 1024 wavelengths can be measured at once
  • Single wavelength type and multi wavelength type
  • Support modulated light and filter measurement

Yokogawa AQ2212 – 9 Slot Frame Controller

  • 9 Slot Mainframe
  • Easy-to-view color display
  • USB port for data storage
  • Measurement module “hot-swapping” capability
  • Remote monitoring and measurement through a LAN

Yokogawa AQ2200 – Modular Manufacturing Test Systems

  • 3 or 9 slot Mainframe
  • Hot-swappable modules
  • A broad lineup of measurement modules
  • Grid tunable laser source, Optical power meter, Optical attenuator, Optical switch, etc.
  • Macro Programming Function; a convenient solution for automated measurements eliminating need for an external PC controller.
  • Remote interfaces : GP-IB, Ethernet, and USB
  • Multi-user function
  • Remote Viewer Software
  • Stability / Logging Function

Yokogawa AQ2200-131/132 – Grid Light Source Modules

  • Frequency (Wavelength): C-band, L-band
  • High-stability output level: ± 0.03dB
  • High-stability frequency(wavelength): ± 0.3GHz (± 2.4pm)
  • Output level: +9dBm or more
  • High SMSR: 45dB

Yokogawa AQ2200-215 – High Power Sensor Modules

  • High Power Measurement: +30dBm
  • High-Speed Sampling: 10,000 points per second
  • Various Optical Connectors: FC/SC/MU/LC
  • Fully Configurable: Create the desired measurement system by combining AQ2200 Series modules with Yokogawa optical communications measuring instruments

Yokogawa AQ2200-222 – Dual Sensor Modules

  • Ideal for powerful yet compact systems.
  • Wide wavelength range: 800 to 1700 nm
  • Wide power range: -90 to +15 dBm
  • High-speed measurement: 100 µs (minimum sampling period)
  • Optical connector compatibility: FC, SC, MU, and LC
  • Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems.

Yokogawa AQ2200-312 – Optical Attenuator Module

  • Wide attenuation range:
    • 0 to 60 dB (SM version)
    • 0 to 45 dB (MM version)
  • Wide wavelength range:
    • 1200 to 1700 nm(SM version)
    • 800 to 1370 nm (MM version)
  • Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
  • Low insertion loss: 1.0 dB (typical)
  • Low polarization dependence loss: 0.1 dBp-p or less
  • Monitor output (optional)
  • Configure the desired measurement system by combining AQ2200 Series modules with Yokogawa optical communications measuring instruments

Yokogawa AQ2200-332 – Optical Attenuator Module

  • Compact: The AQ2200-332 features an optical variable attenuator and an optical power meter for monitoring the optical output power in a one-slot module. Ideal for bit error testing
  • Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
  • Attenuation accuracy: within ±0.1 dB
  • With the output monitoring function, the AQ2200-332 allows direct setup of optical power at the output terminals
  • Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems

Yokogawa AQ2200-411 – Optical Switch Module

  • Compact: Optical switches of 1 x 4 or 1 x 8 port configuration in a one-slot size module
  • Compatible with SMF (core diameter of 10 µm) or MMF (core diameter of 62.5 µm)
  • Low insertion loss: 1.0 dB (typ.)
  • High switching reproducibility: within ±0.01 dB
  • Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems

Yokogawa AQ2200-412 – Optical Switch Module

  • Compact: Optical switches of 1 x 16 port configuration in a two-slot size module
  • Compatible with SMF(10/125µm) or MMF(50/125µm)
  • Low insertion loss: 1.0 dB (typ.)
  • High switching reproducibility: within ±0.01 dB
  • Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems

Yokogawa AQ2200-421 – Optical Switch Module

  • Compact: Optical switches of 1 x 2 or 2 x 2 port configuration in a one-slot size module
  • Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
  • Low insertion loss: 1.0 dB (typ.)
  • High switching reproducibility: within ±0.01 dB
  • Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems

Yokogawa AQ2200-642 – Transceiver I/F Module

  • Support 10G optical transceivers
    • XFP, SFP+, XENPAK
  • Power supply and power current monitoring
    • Equipped with current limiter
  • I2C/MDIO interface
  • Signal Control
    • User can define the signal names
  • Voltage monitoring of status signals
    • Threshold adjustment for High/Low decision
  • Resistance monitoring for APS SET

Yokogawa AQ4280 – Portable Optical Light Sources

  • Three-wavelengths to address telecom service, plus additional wavelength for maintenance channel.
    AQ4280A ; 1310/1550nm
    AQ4280B ; 1310/1490/1550nm
    AQ4280C ; 1310/1550,1490/1625nm (2 ports)
  • Auto switching of measurement wavelength

Yokogawa AQ6373B – Visible Wavelength Optical Spectrum Analyzers

  • Wavelength range: 350 to 1200nm
  • Wavelength accuracy: ±0.05 nm
  • Wavelength resolution: 0.02 to 10 nm and 0.01nm (400 to 470nm)
  • Max safe input power: +20 dBm
  • Level sensitivity: -80 dBm
  • Dynamic range: ≧60dB
  • Single-mode, Multimode, and Large-core fibers
  • Built-in optical alignment source
  • Wavelength calibration with an external reference source
  • Various analysis functions including the Color analysis function for VIS

Yokogawa AQ6374 – Wide Range Optical Spectrum Analyzers

  • Wavelength range: 350 to 1750nm
  • High wavelength accuracy: ±0.05nm
  • High wavelength resolution: 0.05 to 10 nm
  • Wide dynamic range: 60dB (peak ±1.0nm)
  • Wide level range: +20 to -80dBm
  • Fast measurement: 0.5 sec. (100nm span)
  • 8 wavelength resolution settings: 0.05 to 10 nm
  • wide measurable level range is from−80 to +20 dBm
  • ±0.05 nm wavelength accuracy can be maintained by the calibration
  • Fast Measurement 0.5 s for 100 nm span (with sensitivity set to NORM_AUTO)