GE/ITI |
 |
III 1Ø Control Power Transformers
Single-Phase 5kV, 60kV BIL
- Meet IEEE C57.12.01 requirements
- Primary windings vacuum cast for high dielectric strength.
- Construction high quality grain-oriented core steel & copper conductor
- Units are partial discharge tested per Canadian Standard C9-M1981
- Standard voltages 120/240 for 1Ø and 208Y/120 for 3Ø & others.
III 1Ø Control Power Transformers
1Ø, 15kV, 95kV BIL; 25 kV, 125kV BIL; 34.5 kV, 150 kV BIL
- Primary windings vacuum cast for high dielectric strength.
- Construction high quality grain-oriented core steel & copper conductor
- Units are partial discharge tested per Canadian Standard C9-M1981
- Standard 120/240V for 1Ø and 208Y/120V for 3Ø & others.
III 3Ø Control Power Transformers
3Ø; 5 kV @ 60 kV BIL; & 15 kV @ 95 kV BIL
- Meet IEEE C57.12.01 requirements
- Primary windings vacuum cast for high dielectric strength.
- Construction high quality grain-oriented core steel & copper conductor
- Units are partial discharge tested per Canadian Standard C9-M1981
- Standard voltages 120/240 for 1Ø and 208Y/120 for 3Ø & others.
GE/ITI |
 |
III 600 Volt Class Current Transformers
600 Volt Class – Commercial Grade
Indoor Instrument Toroids
- Meet IEEE C57.12.01 requirements
- UL recognized – file number E93779
- High accuracy and burden capability
- Some models have on-board primary and secondary fuses
III 600 Volt Class Current Transformers
Low Voltage CTs 600 Indoor Instrument Grade Bar
- Primary Currents: 200 to 800 amps
- Core and coil are enclosed in a case molded with GE Valox® thermoplastic polyester resin
- Secondary terminals are tin plated brass, compression type
- Primary bars from copper tube, tin plated, ANSI C12.11
III 600 Volt Class CTs
600 V Indoor Instrument Grade Toroid
- High Accuracy
- UL E93779
- IEEE C57.13
- can be designed to meet IEC-44-1
- 600V, BIL 10kV, Primary currents 50 to 6000 amps
III 600 Volt CTs
600V Indoor Rectangular Window
- Used for metering and relaying
- Several models are designed to fit over bus bars in low voltage switchgear
- UL E93779 & IEEE C57.13
- 600V BIL 10kV
III 600 Volt Class CTs
600V Indoor Three Phase
- Many different models with numerous window sizes and phase centers
- A zero sequence core to reduce installation space is also available in many models
- UL E93779 & IEEE C57.13
- 600V BIL 10kV
III 600 Volt Class CTs
Multi-Ratio Toroid
- These models provide up to ten different ratios from one CT.
- A zero sequence core to reduce installation space is also available.
- UL E93779 & IEEE C57.13
- 600V BIL 10kV 50-5000 A
III 600 Volt Class CTs
600 V Rectangular Window Indoor Current Transformers
- Weatherproof design suitable for outdoor use is also available
- UL E93779 & IEEE C57.13
- 600V BIL 10kV 10-5000 A
III 600 Volt Class CTs
600V Indoor Wound Primary/Auxiliary Indoor
- High accuracy at low currents
- 4 kV primary to secondary isolation (wound primaries)
- UL E93779 & IEEE C57.13
- 600V BIL 10kV 5-50 A
GE/ITI |
 |
III Current Transformers Single Phase and Three Phase
600V Class 1Ø and 3Ø Indoor Voltage Transformers
- UL E93779 & IEEE C57.13
- High accuracy and burden capability
- Some models have onboard primary and secondary fuses
- Units can be designed to meet the requirements of IEC-44-2.
III Voltage Transformers
120V – 69kV Class Outdoor Voltage Transformers
- Accubute™ high accuracy models.
- Improved equity in billing at all loads, especially light loads
- Transformers for all metering applications including cogeneration