DEIF WSK – Primary Winding Transformer

  • Primary Current: 1-100 A
  • Secondary Current: 5 or 1 A
  • Burden: 2.5 – 15 VA
  • Accuracy Class/Protection Class: 0.5 – 1.0

GE / ITI 100 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″

GE / ITI 10WP Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave

GE / ITI 110 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″

GE / ITI 112, 113, 114, 115, & 117 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.25″, 2.75″, 3.25″, 4.00″ & 4.62″
  • Available in Multi-Ratio (MR)

GE / ITI 12 & 13 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 0.37″ & 0.56″

GE / ITI 120 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″

GE / ITI 125 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.31″

GE / ITI 126 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.25″

GE / ITI 130 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″

GE / ITI 135 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 137 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.50″
  • Available in Multi-Ratio (MR)

GE / ITI 139 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″
  • Available in Multi-Ratio (MR)

GE / ITI 14, 15 & 16 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 0.64″, 0.94″ & 1.25″

GE / ITI 140 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.13″
  • Available in Multi-Ratio (MR)

GE / ITI 141 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.13″
  • Available in Multi-Ratio (MR)

GE / ITI 142 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.25″
  • Available in Multi-Ratio (MR)

GE / ITI 143 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.31″
  • Available in Multi-Ratio (MR)

GE / ITI 144 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.00″
  • Available in Multi-Ratio (MR)

GE / ITI 145 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.00″
  • Available in Multi-Ratio (MR)

GE / ITI 146 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.75″

GE / ITI 147 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 10.00″

GE / ITI 170 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.25″

GE / ITI 180 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″

GE / ITI 183 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.50″

GE / ITI 188 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave

GE / ITI 189 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave

GE / ITI 19 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.25″

GE / ITI 190 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave

GE / ITI 191, 192, 193, 194 & 195 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.25″, 1.75″, 2.13″, 2.50″, 3.06″

GE / ITI 2 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.00″, 1.13″

GE / ITI 20 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave

GE / ITI 200, 201, 202, 203 & 204 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″, 3.50″, 4.88″, 5.25″, 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 200WP Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave

GE / ITI 21, 22, 23, 24 & 25 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.25″, 1.63″, 2.00″, 2.50″ & 3.13″

GE / ITI 21I Series – IEC Rated 50 Hz Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 31.7 mm

GE / ITI 22I Series – IEC Rated 50 Hz Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 41.4 mm

GE / ITI 23I Series – IEC Rated 50 Hz Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 50.8 mm

GE / ITI 24I Series – IEC Rated 50 Hz Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 63.5 mm

GE / ITI 25I Series – IEC Rated 50 Hz Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 79.5 mm

GE / ITI 296, 297, 298, 299 & 300 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.50″, 2.25″, 3.00″, 3.38″ & 3.75″

GE / ITI 296I Series – IEC Rated Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 38.1 mm

GE / ITI 297I Series – IEC Rated Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 57.2 mm

GE / ITI 298I Series – IEC Rated Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 76.2 mm

GE / ITI 299I Series – IEC Rated Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 720 Volts
  • Window Diameter: 85.9 mm

GE / ITI 2DARL Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.00″

GE / ITI 2VT460 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 150 VA at 30C/100 VA at 55C
  • Accuracy Class: 0.6 W, 1.2 X

GE / ITI 2VT469 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 40 VA at 30C/27 VA at 55C
  • Accuracy Class: + 1% at all burdens up to 5 VA at 1.0 and 0.95 P.F.