Yokogawa 2553A – Precision DC Calibrator
- Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
- High resolution: 5.5 digits ±120000 count output resolution
- DC Voltage: ±10 mV to ±30 V
- DC Current: ±1 mA to ±100 mA
- Voltage accuracy: +/- 75 ppm
- Current accuracy: +/- 120 ppm
- Temperature calibration: 10 types of thermocouples including K, T, E, and J types
- User-defined thermocouple and RTD (PT1000) calibration: Generates various types of thermocouple and RTD by extrapolating the relation between voltage and temperature
Yokogawa LS3300 – AC Power Calibrator
- High Accuracy:
- AC Voltage: ±350 ppm
- AC Current: ±450 ppm
- AC Power: ±450 ppm
- Phase Accuracy: ±0.03˚ at 50/60 Hz
- High Stability:
- AC voltage: ±50 ppm/h
- AC current: ±50 ppm/h
- AC power: ±100 ppm/h
- Wide Generation Range:
- AC voltage: 10 mV to 1250 V
- AC current: 0.3 mA to 62.5 A
- Frequency: 40 to 1200 Hz
Yokogawa 2558A – Precision AC Standard
- Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
- 6 voltage ranges (100 m/1/10/100/300/1000 V)
- 4 current ranges (100 m/1/10/50 A)
- Sweep (Voltage/Current/Frequency)
- Output Divider: Linearity tests can be simply performed by dividing the output into steps. For example, a setting of 4 will generate steps of 25, 50, 75 and 100% of the set output value.
- % Deviation readout
- Common current output terminals: The same output terminals are used for all current ranges. Test times are therefore reduced by avoiding the need to change the wiring for meters which have different ranges.
- Wide frequency range-: 40 to 1000 Hz (Frequency accuracy : ±50 ppm)
Yokogawa 2560A – Precision DC Calibrator
- Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
- High resolution: 5.5 digits ±120000 count output resolution
- Accuracy:
- DC voltage: ±50 ppm
- DC current: ±70 ppm
- Resolution:
- 5.5 digits, ±120000 count display
- 6.5 digits, ±1200000 count display – high res.
- Direct readout of the deviation
- Digital display of output
- Output Divider
- Sweep: With a flick of a switch, the output can be swept within the source range with sweep times of 8, 16, 32 or 64 seconds.
- High stability
- DC voltage: ±10 ppm/h
- DC current: ±20 ppm/h
Yokogawa CA310 – Process Calibrator
- Basic Accuracy: 0.015% (Source&Meas. accuracy of Voltage mA)
- 20 mA SIMULATE (SINK) function
- Simultaneously supplies 24 V loop power and measure output signal with high accuracy
- HART/BRAIN comm. resistance (250Ω) embedded
- Sub display displays span% of the source value
- Corresponds to various types of source pattern (Step sweep/ Linear sweep/ Manual step/ Span check)
- Sources by 25% step automatically from 0% to 100% of span
- Sources by 25% step manually from 0% to 100% of span.
- Simple operation, easy to use
- Rotary switch range selector
- Linear Sweep Function
- Lightweight, compact body
- Span Check Function
Yokogawa CA320 – Process Calibrator
- Basic accuracy: 0.5°C (Typical of TC type K)
*Including accuracy of internal RJC - Sub display displays value of voltage source and span%
- Corresponds to 16 types of TC standard
(JIS/IEC/DIN/ASTM/GOST R) - Corresponds to various types of source pattern
(Step sweep/ Linear sweep/ Manual step/ Span check) - Corresponds to other TC types by mV source function
- Measures TC sensor output as a thermometer
Yokogawa CA330 – Process Calibrator
- Basic accuracy: 0.3°C (Typical of PT100)
- Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)
- Sub display displays value of resistance source and span%
- Corresponds to various types of source pattern
(Step sweep/ Linear sweep/ Manual step/ Span check) - Corresponds to 2,3,4 wire. Realizes RTD simulation
- Measures output of RTD sensor as a thermometer
- Sources by 25% step automatically from 0% to 100% of span
- Sources by 25% step manually from 0% to 100% of span.
- Simple operation, easy to use
- Rotary switch range selector
- Linear Sweep Function
- Lightweight, compact body
- Span Check Function
Yokogawa CA450 – Process Multimeter
- Display: 5-digit LCD (7 segment)
- Loop power and 4-20 mA
- Generation function
- DC mA 0.05%/30.000 mA
Yokogawa CA500 – Multi-Function Process Calibrator
- Sources and measures DC voltage, DC current, RTD, TC, resistance, frequency and pulse signals
- Corresponds to 17 types of TC standard (JIS/IEC/DIN/ASTM/GOST R)
- Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)
- Linear sweep function: Continuously Source from 0% to 100%
- Step sweep function: Change output in a staircase (step) pattern by specifying the number of steps. (The number of steps can be set from 2 to 20)
- Program sweep function: Users can set the desired output value (%) and number of steps. (10 steps for CA500, 20 steps for CA550)
Yokogawa CA700 – Precision Pressure Calibrator
- High Accuracy and Long Stability:Â Achieves the highest accuracy in the portable class
- Basic accuracy:Â Pressure (measurement) / 0.01% rdg. Current/voltage (source/measurement) / 0.015% rdg
- Rangeability – Achieves the highest resolution and widest range in the portable class
- User Support – Strong support for field calibration and maintenance work
- Calibration procedures of pressure transmitters and pressure switches are embedded
- IP54 dustproof and waterproof robust case enables use in harsh environments
- Three high-performance hand pump models for different pressure ranges are available
Yokogawa CA71 – Multifunction Calibrator
- Source and measure operations can be performed at the same time
(Select from the following source signal and measurement signal options: voltage, current, resistance, thermocouple (TC), resistance temperature detector (RTD),frequency, pulse) - AC voltages, including supply voltage, can be measured
- Divided output (n/m) function, Auto-step function, Sweep function, Memory function and Communication function are available
- 20 mA SINK Function
- 4−20 mA Step Function
- Equivalent Output of TC/RTD and Built-in Reference Junction Compensation Sensor
- Generation and Measurement of Pulse Generation and Measurement of Voltage Pulse and Contact Pulse
- Pulse Cycle Function
- CPM (count/min), CPH (count/hour) Function
- Memory Function: can handle a maximum of 50 sets of data by means of its built-in memory
Yokogawa MC100 – Pneumatic Pressure Standard
- High accuracy ±(0.05% of full scale)
- Excellent stability provided by silicon resonant sensor
- Low temperature coefficient
- Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C
- Divided output function with as many as 20 steps
- Autostep output function
- Sweep output function
- Offset monitor function to present deviation from final value