Accuenergy AcuCT 5A – Split Core Current Transformers

  • 0.5% accuracy from 10%-120% of rated current
  • 100A to 5000A measurement range
  • Industrial standard 5A secondary output
  • Optional 1A output
  • Accessory kits included for mounting in multiple locations
  • UL recognized

Accuenergy AcuCT Flex – Flexible Rogowski Coil Current Transformers

  • High accuracy for demanding applications
  • Wide frequency range means excellent choice for harmonics and power quality
  • Wide current input range from 5A – 50,000A AC
  • Choice of 16″, 24″, 36″ or 47″ length
  • No additional power supply needed when used with Acuvim II Series meters
  • Fully customizable selection of flexible CT

Accuenergy AcuCT Hinged – Split Core Current Transformers

  • Quick & simple installation with hinged clip
  • Safe mV secondary output
  • 5A – 600A AC current input range
  • 0.5% accuracy from 10-120% of rated current
  • UL recognized

Accuenergy AcuCT mV – Split Core Current Transformers

  • Conventional 333 mV split-core CT
  • Safe mV secondary output
  • 0.5% accuracy from 10-120% of rated current
  • 20A – 5000A AC current input range
  • UL recognized

Accuenergy AcuCT R – Split Core Current Transformer

  • 5A – 5000A AC current input range
  • Revenue grade accuracy IEC 60044-1 0.5s class
  • UL listed for XOBA UL2808 standard, CSA C22.2 No. 61010-1
  • Push-open mechanism makes the installation quick and simple
  • Multiple voltage or current secondary output options including 5A and 333mVMultiple mounting options with included accessories
  • Multiple window shapes and sizes for multiple applications

Accuenergy AcuCT S113 – Solid Core Current Transformers

  • 1% Class Accuracy
  • 1.2In RF
  • 50Hz-60Hz Rated Frequency
  • ≤±1.0% Ratio Error
  • ≤60 Phase Error
  • 5-120% Measurement Range
  • 500V / 100 MΩ min insulation resistance

Accuenergy AcuCT S77 – Solid Core Current Transformers

  • 0.15 class accuracy
  • 10 kV impulse insulation (BIL)
  • 50 MΩ insulation resistance
  • 18 AWG UL 1015 Lead Wire
  • Measurement Canada Approved

Accuenergy Rogowski Integrator Kit – 5A

  • 0-5A rated output that works with any power meter or equipment with 5A nominal current transformer input
  • Individual CT ratios can be configured for each channel. Works in any single-phase application with different current ratings
  • Works in both 50Hz and 60Hz systems

Accuenergy Rogowski Integrator Kit – mA

  • 4-20mA or 0-20mA rated output that works with any analog input controller
  • Current sensing range from 2.5A to 50,000A to fit all systems
  • Designed to easily fit into panels or busbars where space may be limited

Accuenergy Rogowski Integrator Kit – mV

  • 0-333mV rated output that works with any power meter or equipment with 333mV nominal current transformer input
  • CT ratios: 500A, 1kA, 2.5kA, 5kA, 10kA, 25kA, 50kA
  • Individual CT ratios can be configured for each channel

Accuenergy Rogowski Integrator Kit – V

  • 0-5Vdc or 0-10Vdc rated output that works with any energy meter or device
  • Measurement Channels: Three-phase or single-phase
  • Works in both 50Hz and 60Hz systems

GE / ITI 100 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″

GE / ITI 110 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″

GE / ITI 112, 113, 114, 115, & 117 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.25″, 2.75″, 3.25″, 4.00″ & 4.62″
  • Available in Multi-Ratio (MR)

GE / ITI 12 & 13 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 0.37″ & 0.56″

GE / ITI 120 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″

GE / ITI 125 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.31″

GE / ITI 126 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.25″

GE / ITI 130 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″

GE / ITI 135 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 137 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.50″
  • Available in Multi-Ratio (MR)

GE / ITI 139 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″
  • Available in Multi-Ratio (MR)

GE / ITI 14, 15 & 16 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 0.64″, 0.94″ & 1.25″

GE / ITI 140 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.13″
  • Available in Multi-Ratio (MR)

GE / ITI 141 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.13″
  • Available in Multi-Ratio (MR)

GE / ITI 142 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.25″
  • Available in Multi-Ratio (MR)

GE / ITI 143 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.31″
  • Available in Multi-Ratio (MR)

GE / ITI 144 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.00″
  • Available in Multi-Ratio (MR)

GE / ITI 145 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.00″
  • Available in Multi-Ratio (MR)

GE / ITI 146 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.75″

GE / ITI 147 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 10.00″

GE / ITI 170 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.25″

GE / ITI 180 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″

GE / ITI 183 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.50″

GE / ITI 19 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.25″

GE / ITI 191, 192, 193, 194 & 195 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.25″, 1.75″, 2.13″, 2.50″, 3.06″

GE / ITI 2 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.00″, 1.13″

GE / ITI 200, 201, 202, 203 & 204 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″, 3.50″, 4.88″, 5.25″, 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 21, 22, 23, 24 & 25 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.25″, 1.63″, 2.00″, 2.50″ & 3.13″

GE / ITI 296, 297, 298, 299 & 300 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.50″, 2.25″, 3.00″, 3.38″ & 3.75″

GE / ITI 2DARL Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.00″

GE / ITI 306 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 307 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 308 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 309 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 311MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Multi-Ratio (MR)

GE / ITI 386 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 387 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 388 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 389 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 3P1 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.31″

GE / ITI 3P10 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.58″ x 0.26″

GE / ITI 3P18 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.19″

GE / ITI 3P2 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.69″

GE / ITI 3P27 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.44″x 0.44″

GE / ITI 3P28 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″x 0.82″

GE / ITI 3P3 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.97″

GE / ITI 3P30 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.88″

GE / ITI 3P4 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″

GE / ITI 3P40 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.75″

GE / ITI 3P41 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.03″

GE / ITI 3P42 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.50″

GE / ITI 3P43 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.00″

GE / ITI 3P5 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″

GE / ITI 3P528 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.33″ x 5.20″

GE / ITI 3P56 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.13″

GE / ITI 3P665 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.63″ x 4.88″

GE / ITI 3P667 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.75″

GE / ITI 3P668 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.66″

GE / ITI 3P669 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.87″ x 6.30″

GE / ITI 3P670 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.88″

GE / ITI 3P80 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.00″

GE / ITI 3P81 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.63″

GE / ITI 3P82 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″

GE / ITI 3P83 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.55″ x 0.45″

GE / ITI 3P84 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.05″ x 0.50″

GE / ITI 3P85 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.08″

GE / ITI 3P86 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.55″ x 0.25″

GE / ITI 3P9 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.25″ x 0.25″ Full Radius

GE / ITI 3P90 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.63″

GE / ITI 3P91 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.12″

GE / ITI 3P92 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.56″ x 2.12″

GE / ITI 3P93 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.88″

GE / ITI 5 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.56″

GE / ITI 500 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: Available up to 10″ x 30″

GE / ITI 510 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.63″ x 8.25″

GE / ITI 520 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.44″ x 1.22″

GE / ITI 521 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″ x 0.59″

GE / ITI 525 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.33″ x 0.59″

GE / ITI 530 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.88″ x 3.06″”

GE / ITI 531 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.06″ x 3.06″

GE / ITI 540, 541, 542 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.53″ x 1.53″, 0.53″x 3.03″, 0.53″x 4.03″

GE / ITI 543, 544, 545, 546, 547, 548 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.53″ x 1.53″, 0.53″x 3.03″, 0.53″x 4.03″

GE / ITI 550 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.1″ to 10.1″ x 7.1″ to 30.1″

GE / ITI 56 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.06″

GE / ITI 560 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.25″ x 4.25″

GE / ITI 561 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.25″ x 4.25″

GE / ITI 562 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.00″ x 5.38″

GE / ITI 563 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.00″ x 5.38″

GE / ITI 566 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.75″ x 2.25″

GE / ITI 567 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.75″ x 3.75″

GE / ITI 568 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 7.45″ x 3.75″

GE / ITI 569 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 9.50″ x 3.75″

GE / ITI 570 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.56″ x 0.79″

GE / ITI 571 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.58″ x 4.13″

GE / ITI 572 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.66″ x 4.16″

GE / ITI 573 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.43″ x 5.00″

GE / ITI 574 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 2.25″

GE / ITI 575 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 3.25″

GE / ITI 576 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″ x 5.25″

GE / ITI 577 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 2.25″

GE / ITI 578 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 3.25″

GE / ITI 579 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 5.25″

GE / ITI 58 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.25″

GE / ITI 580 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.50″ x 1.00″

GE / ITI 581 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.13″ x 1.13″

GE / ITI 582 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.25″ x 2.00″

GE / ITI 583 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.59″ x 3.12″

GE / ITI 584 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.37″ x 3.15″

GE / ITI 585 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 6.90″ x 3.15″

GE / ITI 586 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″ x 3.56″

GE / ITI 590 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.28″ x 11.28″

GE / ITI 592 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.00″ x 14.00″

GE / ITI 593 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.06″ x 22.06″

GE / ITI 594 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.06″ x 20.06″

GE / ITI 595 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.56″ x 13.44″

GE / ITI 596 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.56″ x 17.63″

GE / ITI 5A Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.56″

GE / ITI 5DARL Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.56″

GE / ITI 6 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.06″

GE / ITI 60, 61 & 62 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 0.94″, 1.25″ & 1.56″

GE / ITI 600 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″ x 5.50″

GE / ITI 601 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.50″ x 4.50″

GE / ITI 603 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″ x 1.00″, 2.00″ x 2.00″

GE / ITI 604 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.42″ x 1.53″

GE / ITI 606 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.75″ x 2.70″

GE / ITI 608 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.60″ x 6.25″

GE / ITI 610 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.30″ x 1.47″

GE / ITI 613 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.80″ x 1.95″

GE / ITI 614 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 0.75″

GE / ITI 615 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.31″ x 1.66″

GE / ITI 616 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.31″ x 2.16″

GE / ITI 617 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″ x 3.50″

GE / ITI 622 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.25″

GE / ITI 623 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″

GE / ITI 624 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.25″

GE / ITI 625 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″

GE / ITI 680 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.02″

GE / ITI 681MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.02″
  • Multi-Ratio (MR)

GE / ITI 682 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.62″

GE / ITI 685 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.02″

GE / ITI 686MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.02″
  • Multi-Ratio (MR)

GE / ITI 6A Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.06″

GE / ITI 7 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″

GE / ITI 76 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 3.00″

GE / ITI 780 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″

GE / ITI 781MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″
  • Multi-Ratio (MR)

GE / ITI 785 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″

GE / ITI 786MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″
  • Multi-Ratio (MR)

GE / ITI 788 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″
  • Available in Multi-Ratio (MR)

GE / ITI 790 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.00″
  • Available in Multi-Ratio (MR)

GE / ITI 792 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″

GE / ITI 793MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″
  • Multi-Ratio (MR)

GE / ITI 7A Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″

GE / ITI 8 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 3.25″

GE / ITI A & B Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.05″ & 2.06″

GE / ITI CTO Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: Varies, see spec sheet
  • Voltage: 50-4,000 A
  • Thermal Rating: Varies, see spec sheet
  • Window diameter: 7.00″

GE / ITI CTOR Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: Varies, see spec sheet
  • Voltage: 50-4,000 A
  • Thermal Rating: Varies, see spec sheet
  • Window diameter: 8.44″ x 4.50″

GE / ITI CTW3-60-T10 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 5.6 kV, BIL 60 kV
  • Voltage: 50-600 A
  • Thermal Rating: 1.33 at 30C/1.00 at 55C

GE / ITI CTW3-60-T50 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 5.6 kV, BIL 60 kV
  • Voltage: 5-600 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTW6-125 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 25.5 kV, BIL 125 kV
  • Voltage: 10-600 A
  • Thermal Rating: 1.50 at 30C/1.33 at 55C

GE / ITI CTW7-150 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 36.5 kV, BIL 150 kV
  • Voltage: 10-600 A
  • Thermal Rating: 1.50 at 30C/1.33 at 55C

GE / ITI CTWH3-60-T100 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 5.6 kV, BIL 60 kV
  • Voltage: 5-1,200 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH3-A-60-T90 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 5.6 kV, BIL 60 kV
  • Voltage: 5-600 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH4-75-T100 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 9.52 kV, BIL 75 kV
  • Voltage: 5-1,200 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH5-A-110-T150 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Voltage: 5-600 A
  • Thermal Rating: 1.33 at 30C/1.0 at 55C

GE / ITI CTWH5-B-110-T200 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Voltage: 5-1,200 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH5-L-110 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Voltage: 5-600 A
  • Thermal Rating: 1.00 at 30C/0.85 at 55C

GE / ITI CTWH5-S-110 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Voltage: 40-1,200 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH6-125-T200 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 25.5 kV, BIL 125 kV
  • Voltage: 800-3,000 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI HGF3C Series – Ground Fault Current Transformer

  • Ratio: 50:0.025 A
  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.25″

GE / ITI HGF5C Series – Ground Fault Current Transformer

  • Ratio: 50:0.025 A
  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.31″

GE / ITI HGF8 Series – Ground Fault Current Transformer

  • Ratio: 50:0.025 A
  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.13″

GE / ITI JAB-0S RevenueSense Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 600-2,000 A
  • Window Diameter: 4.5″ x 3.5″

GE / ITI JAB-0W Encompass Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 500-1,500 A
  • Window Diameter: 4.5″ x 3.5″

GE / ITI JAD-0C-X Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 200-4000 A
  • Window Diameter: Cross-shaped; see spec sheet for exact dimensions

GE / ITI JAD-0S RevenueSense Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 600-3,000 A
  • Window Diameter: 5.75″

GE / ITI JAD-0W Encompass Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 1,000-1,500 A
  • Window Diameter: 5.75″

GE / ITI JAI-0C & JAU-0C 600V Series – Low Voltage Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.05″, 1.10″, 2.06″ & 3.00″

GE / ITI JAK-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 200-3000 A
  • Window Diameter: 1.50″/2.60″/3.062″

GE / ITI JAK-0S RevenueSense Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 400-1,000 A
  • Window Diameter: 3.062″

GE / ITI JAK-0W Encompass Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 100-500 A
  • Window Diameter: 3.062″

GE / ITI JCD-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 1,500-8,000 A
  • Window Diameter: 8.13″

GE / ITI JCP-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 100-4,000 A
  • Window Diameter: 5.38″

GE / ITI JCR-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 100-400 A
  • Window Diameter: 1.125″/1.50″/2.00″

GE / ITI JCT-0S RevenueSense Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 600 A
  • Window Diameter: 1.31″

GE / ITI JCW-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 100-800 A
  • Window Diameter: 1.125″/1.50″/2.00″

GE / ITI JKM-3 Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 5 kV, BIL 60 kV
  • Voltage: 5-800 A
  • Thermal Rating: 1.5 at 30C/1.0 at 55C

GE / ITI JKM-4 Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 8.7 kV, BIL 75 kV
  • Voltage: 10-800 A
  • Thermal Rating: 1.5 at 30C/1.0 at 55C

GE / ITI JKM-5 Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 15 kV, BIL 110 kV
  • Voltage: 5-800 A
  • Thermal Rating: Variable, see spec sheet