GE / ITI 3P42 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.50″

GE / ITI 3P43 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.00″

GE / ITI 3P5 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″

GE / ITI 3P528 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.33″ x 5.20″

GE / ITI 3P56 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.13″

GE / ITI 3P665 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.63″ x 4.88″

GE / ITI 3P667 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.75″

GE / ITI 3P668 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.66″

GE / ITI 3P669 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.87″ x 6.30″

GE / ITI 3P670 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.88″

GE / ITI 3P80 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.00″

GE / ITI 3P81 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.63″

GE / ITI 3P82 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″

GE / ITI 3P83 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.55″ x 0.45″

GE / ITI 3P84 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.05″ x 0.50″

GE / ITI 3P85 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.08″

GE / ITI 3P86 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.55″ x 0.25″

GE / ITI 3P9 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.25″ x 0.25″ Full Radius

GE / ITI 3P90 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.63″

GE / ITI 3P91 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.12″

GE / ITI 3P92 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.56″ x 2.12″

GE / ITI 3P93 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.88″

GE / ITI 3VT468 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 75 VA at 30C/50 VA at 55C
  • Accuracy Class: ± 0.6% @ 7.5 VA

GE / ITI 3VT471 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 40 VA at 30C/27 VA at 55C
  • Accuracy Class: ±1% @ 5 VA

GE / ITI PT6 Series – Indoor Medium Voltage Transformers

  • Frequency: 60 Hz
  • Maximum System Voltage: 25.5 kV, BIL 125 kV
  • Thermal Rating: 1500 VA at 30C/1000 VA at 55C
  • Accuracy Class: 0.3 WXMY,1.2 Z at 100 % rated voltage with 120 V based ANSI burden.
    0.3 WXMY, 1.2 MY at 58 % rated voltage with 69.3 V based ANSI burden.

GE / ITI PTG3 & PTW3 Series – Indoor Medium Voltage Transformers

  • Frequency: 60 Hz
  • Maximum System Voltage: 5.6 kV, BIL 60 kV
  • Thermal Rating: 750 VA at 30C/500 VA at 55C
  • Accuracy Class: 0.3 WXMY,1.2 Z at 100 % rated voltage with 120 V based ANSI burden.
    0.6 WX, 1.2 MY at 58 % rated voltage with 69.3 V based ANSI burden.

GE / ITI PTG4 & PTW4 Series – Indoor Medium Voltage Transformers

  • Frequency: 60 Hz
  • Maximum System Voltage: 9.52 kV, BIL 75 kV
  • Thermal Rating: 1500 VA at 30C/1000 VA at 55C
  • Accuracy Class: 0.3 WXMY,1.2 Z at 100 % rated voltage with 120 V based ANSI burden.
    0.3 WXMY, 1.2 MY at 58 % rated voltage with 69.3 V based ANSI burden.

GE / ITI PTG5 & PTW5 Series – Indoor Medium Voltage Transformers

  • Frequency: 60 Hz
  • Maximum System Voltage: 15.5 kV, BIL 110 kV
  • Thermal Rating: 1500 VA at 30C/1000 VA at 55C
  • Accuracy Class: 0.3 WXMY,1.2 Z at 100 % rated voltage with 120 V based ANSI burden.
    0.3 WXMY, 1.2 MY at 58 % rated voltage with 69.3 V based ANSI burden.

GE / ITI 3VT472 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 40 VA at 30C/27 VA at 55C
  • Accuracy Class: ± 1% @ 5 VA

GE / ITI 3VTL460 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V line-to-line
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 150 VA at 30C/100 VA at 55C
  • Accuracy Class: 0.6 W, 1.2 X at 60 Hz