Power, voltage, and current transducers are essential devices for measuring and monitoring electrical parameters. They provide accurate data on power consumption, voltage levels, and electric current. Widely used in power monitoring, energy management, and electrical safety applications, these transducers ensure efficient and reliable operation. With their high accuracy and compatibility, they are indispensable tools for engineers and technicians.

Showing all 50 results

GE / ITI PCL Series – AC Current Transducer

  • Input: Up to 75 AAC
  • Output: 4-20 mADC
  • Frequency: 50-60 Hz
  • Insulation Level: 600 V, 10 kV BIL full wave

GE / ITI PCM Series – AC Current Transducer

  • Input: Up to 300 AAC
  • Output: 4-20 mADC
  • Frequency: 50-400 Hz
  • Insulation Level: 600 V, 10 kV BIL full wave

DEIF MTR-4 – Multi-transducer

  • Suitable for all 1- and 3-phase network topologies
  • Up to 1,000 VL-L AC input
  • Accuracy class: 0.5 or 0.3
  • Up to 4 analogue outputs
  • Fast response time, less than 50 ms
  • Measures more than 50 parameters
  • RS-485 serial Modbus communication
  • Fully configurable by USB, no aux. supply required
  • Universal power supply of 19 to 300 V DC/40 to 276 V AC

DEIF TAS-311DG – Selectable Transducer

  • Measures voltage, current, frequency and phase angle on AC networks
  • Class 0.5 measurement
  • Supply and measuring voltage up to 690 V
  • Pre-configuration or easy PC tool configuration
  • Configurable up to three output slopes

DEIF TAS-321DG – Selectable Transducer

  • Measures bi-directional current on AC networks
  • Class 0.5 measurement
  • Supply and measuring voltage up to 690 V
  • Pre-configuration or easy PC tool configuration
  • Configurable up to three output slopes

DEIF TAS-331DG – Selectable Transducer

  • Measures bi-directional current on AC networks
  • Class 0.5 measurement
  • Supply and measuring voltage up to 690 V
  • Pre-configuration or easy PC tool configuration
  • Configurable up to three output slopes

Hsiang Cheng RPA – AC Current Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications.
  • Manufactured to strict compliance IEC 688.
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options.
  • Well-proven applied circuitries, fully ensuring long-term stability.
  • Small sized DIN case for space saving.
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany).
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPF – Power Frequency Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industries’ compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure to meet the requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPPF200 – Power Factor Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure to meet the requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng FPA – AC Current Transducers

  • The FP series are wall mounted electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Accuracy ( 23±3°C ): 0.2% RO
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4

Buy Online

Hsiang Cheng FPV – AC Voltage Transducers

  • The FP series are wall mounted electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Accuracy ( 23±3°C ): 0.2% RO
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4

Buy Online

Hsiang Cheng FPWK – Watt/Var Transducers

  • The FP series are wall mounted electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Accuracy ( 23±3°C ): 0.2% reading / PF ± 0.05% RO
  • High impulse & surge protection of up to 4KV (RMS) meeting IEC 255-3
  • Various phase, wire, and element configurations

Hsiang Cheng RPV – AC Voltage Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPW – Watt Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPWH – WattHour Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPWK – Watt/Var Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng SPA – AC Current Transducers

  • Self – power mode, zero adj. – non required
  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • Rugged steel enclosure of high magnetic immunity
  • Meets IEEE SWC test

Hsiang Cheng SPD – DC Rate Transducers

  • Standard output with 0 to 1 mAdc; Option on request
  • AC 1800V input / output / isolation meets power series requirement
  • Meets IEEE SWC test
  • Dual isolated outputs eliminating ground loop effect (SPD-2 model)

Hsiang Cheng SPK – AC Var Transducers

  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • High magnetic field immunity
  • Meets IEEE SWC test standards

Hsiang Cheng SPV – AC Voltage Transducers

  • Self – power mode
  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • Rugged steel enclosure of high magnetic immunity
  • Meets IEEE SWC test

Hsiang Cheng SPW – AC Watt Transducers

  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • High magnetic field immunity
  • Meets IEEE SWC test standards

Hsiang Cheng SPWK – AC Watt/Var Transducers

  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • Dual isolated output watt / var eliminating ground loops effect
  • High magnetic field immunity
  • Meets IEEE SWC test

Magtrol Torque Transducers

Provides excellent long-term stability and reliability using a highly accurate non-contact measuring technique. Special units made to customer requirements are available.

Magtrol Displacement Transducers

Magtrol’s line of Displacement Transducers provide contactless measurement of absolute piston position in hydraulic and pneumatic cylinders and other applications. Their robust construction, large insensitivity to shocks and very long life (due to no moving parts and therefore no wear of components) make them both cost effective and very reliable.

Sifam Tinsley Theta 20A & 20V – Electrical Transducers

  • Available in Single or Dual output type
  • On-site selectable output type (DC current / DC voltage)
  • Accuracy class 0.2 (IEC/ EN 60 688)
  • Seven Segment LCD Display
  • RS-485(Modbus) Communication

Sifam Tinsley Theta 30P – Electrical Transducers

  • Available in Single or Dual output type
  • On-site selectable output type (DC current / DC voltage)
  • Accuracy class 0.2 (IEC/ EN 60 688)
  • Seven Segment LCD Display
  • RS-485(Modbus) Communication

Veris Hawkeye H221 – Current Transducer

  • Hawkeye 0 to 300 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 1.6 x 1.4 in

Veris Hawkeye H221SP – Current Transducer

  • Hawkeye 100 to 300 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 1.6 x 1.4 in

Veris Hawkeye H321 – Current Transducer

  • Hawkeye 0 to 800 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 2.9 x 2-1/2 in

Veris Hawkeye H321SP – Current Transducer

  • Hawkeye 300 to 800 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 2.9 x 2-1/2 in

Veris Hawkeye H421 – Current Transducer

  • Hawkeye 0 to 2400 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 5-1/2 x 2-1/2 in

Veris Hawkeye H421SP – Current Transducer

  • Hawkeye 1000 to 2400 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 5-1/2 x 2-1/2 in

Veris Hawkeye H721HC – Current Transducer

  • Hawkeye 0 to 50/100/200 A Input 4 to 20 mA DC Output Analog Current Transducer
  • Split-Core
  • 0.7 in

Veris Hawkeye H721LC – Current Transducer

  • Hawkeye 0 to 10/20/40 A Input 4 to 20 mA DC Output Analog Current Transducer
  • Split-Core
  • 0.7 in

Veris Hawkeye H722 – Current Transducer

  • Hawkeye 0 to 60 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H722HC – Current Transducer

  • Hawkeye 0 to 50/100/200 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H722LC – Current Transducer

  • Hawkeye 0 to 10/20/40 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H723HC – Current Transducer

  • Hawkeye 0 to 50/100/200 A Input 0 to 10 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H723LC – Current Transducer

  • Hawkeye 0 to 10/20/40 A Input 0 to 10 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H822 – Current Transducer

  • Hawkeye 0 to 10 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H822-20 – Current Transducer

  • Hawkeye 0 to 20 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H921 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 4 to 20 mA DC Output Analog Current Transducer
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H922 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 0 to 5 VDC Output Analog Current Transducer
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H923 – Current Transducer

  • Hawkeye 0 to 20/100/150 A Input 0 to 10 VDC Output Analog Current Transducer
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H931 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 4 to 20 mA Output Analog Current Transducer with Relay
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H932 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 0 to 5 VDC Output Analog Current Transducer with 24 VAC/VDC SPST Relay
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H952 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 0 to 5 VDC Output Analog Current Transducer with 12 VDC SPST Relay
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H971 – Current Transducer

  • Hawkeye 0 to 200 A DC Input 4 to 20 mA Bi-Directional Output Direct Current Transducer
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H971SP – Current Transducer

  • Hawkeye 0 to 200 A DC Input 4 to 20 mA Bi-Directional Output Direct Current Transducer
  • Split-Core
  • 1.1 x 0.8 in
  • Factory Calibration