Showing 1–8 of 10 results

Rigol DSG3000B Series – RF Signal Generators

  • Maximum Frequency of 6.5- 13.6 GHz
  • Up to -116 dBc/Hz (typical) phase noise
  • Up to +23 dBm (typical) maximum output power
  • Higher level of amplitude accuracy, up to 0.5 dB (typical)

Buy Online

Rigol DSG800 Series – RF Signal Generators

  • Maximum Frequency of 1.5- 3.6 GHz
  • Up to -112 dBc/Hz (typical) phase noise
  • Up to +20 dBm (typical) maximum output power
  • Higher level of amplitude accuracy, up to 0.5 dB (typical)

Buy Online

Yokogawa 2553A – Precision DC Calibrator

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • High resolution: 5.5 digits ±120000 count output resolution
  • Accuracy:
    • Voltage: ±75 ppm* for voltage (one year)
    • Current: ±120 ppm for current (one year)
  • Temperature calibration: 10 types of thermocouples including K, T, E, and J types
  • User-defined thermocouple and RTD calibration: Generates various types of thermocouple and RTD by extrapolating the relation between voltage and temperature

Yokogawa LS3300 – AC Power Calibrator

  • High Accuracy:
    • AC Voltage: ±350 ppm
    • AC Current: ±450 ppm
    • AC Power: ±450 ppm
  • Phase Accuracy: ±0.03˚ at 50/60 Hz
  • High Stability:
    • AC voltage: ±50 ppm/h
    • AC current: ±50 ppm/h
    • AC power: ±100 ppm/h
  • Wide Generation Range:
    • AC voltage: 10 mV to 1250 V
    • AC current: 0.3 mA to 62.5 A
    • Frequency: 40 to 1200 Hz

Yokogawa 2558A – Precision AC Standard

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • 6 voltage ranges (100 m/1/10/100/300/1000 ([V])
  • 4 current ranges (100 m/1/10/50 ([A])
  • Sweep (Voltage/Current/Frequency)
  • Output Divider: Linearity tests can be simply performed by dividing the output into steps. For example, a setting of 4 will generate steps of 25, 50, 75 and 100% of the set output value.
  • % Deviation readout
  • Common current output terminals: The same output terminals are used for all current ranges. Test times are therefore reduced by avoiding the need to change the wiring for meters which have different ranges.
  • Wide frequency range-: 40 to 1000 Hz (Frequency accuracy : ±50 ppm)

Yokogawa 2560A – Precision DC Calibrator

  • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
  • High resolution: 5.5 digits ±120000 count output resolution
  • Accuracy:
    • DC voltage: ±50 ppm
    • DC current: ±70 ppm
  • Resolution:
    • 5.5 digits, ±120000 count display
    • 6.5 digits, ±1200000 count display – high res.
  • Direct readout of the deviation
  • Digital display of output
  • Output Divider
  • Sweep: With a flick of a switch, the output can be swept within the source range with sweep times of 8, 16, 32 or 64 seconds.
  • High stability
    • DC voltage: ±10 ppm/h
    • DC current: ±20 ppm/h

Yokogawa FG400 – Isolated Arbitrary/ Function Generator

  • High accuracy ±(0.05% of full scale)
  • Excellent stability provided by silicon resonant sensor
  • Low temperature coefficient
  • Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C
  • Divided output function with as many as 20 steps
  • Autostep output function
  • Sweep output function
  • Offset monitor function to present deviation from final value

Yokogawa GS200 – DC Voltage / Current Source

  • Source and sink operation up to 110 V/3.2 A (four-quadrant operation)
  • Basic accuracy: ±0.02% (DC voltage generation)
  • Sweep output at up to 100μs intervals
  • Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)
  • Stores up to 65535 points of source measure data in the internal memory
  • Easy file operation with the USB storage function
  • Remote control and FTP using Web server function (Optional)