Showing all 37 results

Hsiang Cheng RPA – AC Current Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications.
  • Manufactured to strict compliance IEC 688.
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options.
  • Well-proven applied circuitries, fully ensuring long-term stability.
  • Small sized DIN case for space saving.
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany).
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPF – Power Frequency Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industries’ compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure to meet the requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPPF200 – Power Factor Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure to meet the requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPV – AC Voltage Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPW – Watt Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPWH – WattHour Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPWK – Watt/Var Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng SPA – AC Current Transducers

  • Self – power mode, zero adj. – non required
  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • Rugged steel enclosure of high magnetic immunity
  • Meets IEEE SWC test

Hsiang Cheng SPD – DC Rate Transducers

  • Standard output with 0 to 1 mAdc; Option on request
  • AC 1800V input / output / isolation meets power series requirement
  • Meets IEEE SWC test
  • Dual isolated outputs eliminating ground loop effect (SPD-2 model)

Hsiang Cheng SPK – AC Var Transducers

  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • High magnetic field immunity
  • Meets IEEE SWC test standards

Hsiang Cheng SPV – AC Voltage Transducers

  • Self – power mode
  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • Rugged steel enclosure of high magnetic immunity
  • Meets IEEE SWC test

Hsiang Cheng SPW – AC Watt Transducers

  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • High magnetic field immunity
  • Meets IEEE SWC test standards

Hsiang Cheng SPWK – AC Watt/Var Transducers

  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • Dual isolated output watt / var eliminating ground loops effect
  • High magnetic field immunity
  • Meets IEEE SWC test

Veris Hawkeye H221 – Current Transducer

  • Hawkeye 0 to 300 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 1.6 x 1.4 in

Veris Hawkeye H221SP – Current Transducer

  • Hawkeye 100 to 300 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 1.6 x 1.4 in

Veris Hawkeye H321 – Current Transducer

  • Hawkeye 0 to 800 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 2.9 x 2-1/2 in

Veris Hawkeye H321SP – Current Transducer

  • Hawkeye 300 to 800 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 2.9 x 2-1/2 in

Veris Hawkeye H421 – Current Transducer

  • Hawkeye 0 to 2400 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 5-1/2 x 2-1/2 in

Veris Hawkeye H421SP – Current Transducer

  • Hawkeye 1000 to 2400 A Input 4 to 20 mA DC Output High Analog Current Transducer
  • Split-Core
  • 5-1/2 x 2-1/2 in

Veris Hawkeye H721HC – Current Transducer

  • Hawkeye 0 to 50/100/200 A Input 4 to 20 mA DC Output Analog Current Transducer
  • Split-Core
  • 0.7 in

Veris Hawkeye H721LC – Current Transducer

  • Hawkeye 0 to 10/20/40 A Input 4 to 20 mA DC Output Analog Current Transducer
  • Split-Core
  • 0.7 in

Veris Hawkeye H722 – Current Transducer

  • Hawkeye 0 to 60 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H722HC – Current Transducer

  • Hawkeye 0 to 50/100/200 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H722LC – Current Transducer

  • Hawkeye 0 to 10/20/40 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H723HC – Current Transducer

  • Hawkeye 0 to 50/100/200 A Input 0 to 10 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H723LC – Current Transducer

  • Hawkeye 0 to 10/20/40 A Input 0 to 10 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H822 – Current Transducer

  • Hawkeye 0 to 10 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H822-20 – Current Transducer

  • Hawkeye 0 to 20 A Input 0 to 5 VDC Output Analog Current Transducer
  • Solid-Core
  • 0.7 in

Veris Hawkeye H921 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 4 to 20 mA DC Output Analog Current Transducer
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H922 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 0 to 5 VDC Output Analog Current Transducer
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H923 – Current Transducer

  • Hawkeye 0 to 20/100/150 A Input 0 to 10 VDC Output Analog Current Transducer
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H931 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 4 to 20 mA Output Analog Current Transducer with Relay
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H932 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 0 to 5 VDC Output Analog Current Transducer with 24 VAC/VDC SPST Relay
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H952 – Current Transducer

  • Hawkeye 0 to 30/60/120 A Input 0 to 5 VDC Output Analog Current Transducer with 12 VDC SPST Relay
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H971 – Current Transducer

  • Hawkeye 0 to 200 A DC Input 4 to 20 mA Bi-Directional Output Direct Current Transducer
  • Split-Core
  • 1.1 x 0.8 in

Veris Hawkeye H971SP – Current Transducer

  • Hawkeye 0 to 200 A DC Input 4 to 20 mA Bi-Directional Output Direct Current Transducer
  • Split-Core
  • 1.1 x 0.8 in
  • Factory Calibration