<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AC Electronic Loads &#8211; Electro-Meters</title>
	<atom:link href="https://www.electro-meters.com/product-category/electronic-loads/ac-electronic-loads/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.electro-meters.com/product-category/electronic-loads/ac-electronic-loads/</link>
	<description>Technology for all your measurement needs</description>
	<lastBuildDate>Fri, 29 Apr 2022 14:19:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.electro-meters.com/wp-content/uploads/images/electro-meters/cropped-EMlogo_square-32x32.png</url>
	<title>AC Electronic Loads &#8211; Electro-Meters</title>
	<link>https://www.electro-meters.com/product-category/electronic-loads/ac-electronic-loads/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Preen PEL Series &#8211; Regenerative AC Electronic Load</title>
		<link>https://www.electro-meters.com/product/preen-pel-series-regenerative-ac-electronic-load/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Tue, 02 Mar 2021 19:42:52 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=1213</guid>

					<description><![CDATA[<ul>
<li>Constant current (CC), constant resistance (CR) and constant power (CP) modes to simulate power factor from 0.3 to 1.0 (lead / lag)</li>
<li>Recycles power back to grid with efficiency greater than 90%</li>
<li>High power factor in grid connected side: up to 0.99</li>
</ul>
<p>The post <a href="https://www.electro-meters.com/product/preen-pel-series-regenerative-ac-electronic-load/">Preen PEL Series &#8211; Regenerative AC Electronic Load</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PEL Series is an AC electronic load with regenerative function. Traditional resistive AC loads transfer the energy to heat which is dissipated. PEL not only transfers energy back to the grid and reduces the energy consumption, but also provides more accurate control and measurement for load simulation. PEL employs the most advanced PWM rectification (active rectification) technology with four-quadrant operation and digital signal processor technology (DSP). It not only can simulate different load characteristics including resistance and inductive type, but also can feed energy back to the grid, which lowers energy consumption and improves carbon dioxide emissions.</p>
<p><strong>Applications</strong><em><strong>:</strong></em> Burn-in tests, production line and laboratory applications to replace the traditional resistive type AC load bank.</p>
<ul>
<li>Constant current (CC), constant resistance (CR) and constant power (CP) modes to simulate power factor from 0.3 to 1.0 (lead / lag)</li>
<li>Recycles power back to grid with efficiency greater than 90%</li>
<li>High power factor in grid connected side: up to 0.99</li>
<li>Can be paralleled for larger capacity demands</li>
<li>Three-phase independent control to set voltage of each phase</li>
<li>Adjustable parameters including PF, current, power, resistance etc.</li>
<li>Touch screen display for easy operation</li>
<li>Comprehensive protection includes over voltage, over current, over load, input under voltage and over temperature with over 20 corresponding error codes and event log for easier troubleshooting</li>
<li>Standard RS485 communication interface</li>
<li>Latest patented power module with high power density and swappable design for better reliability and serviceability</li>
</ul>
<p>The post <a href="https://www.electro-meters.com/product/preen-pel-series-regenerative-ac-electronic-load/">Preen PEL Series &#8211; Regenerative AC Electronic Load</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ITECH IT8600 Series &#8211; AC/DC Electronic Loads</title>
		<link>https://www.electro-meters.com/product/itech-it8600-series-ac-dc-electronic-loads/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Wed, 24 Feb 2021 15:41:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=1113</guid>

					<description><![CDATA[<p>IT8600 is ITECH latest series of AC/DC electronic loads with power range 0~14.4 kVA and adjustable frequency 45 Hz ~ 450 Hz. The unique oscilloscope waveform display function of IT8600's can display input voltage &#38; current as waveform. It is equipped with measurement modes for different parameters such as inrush current, peak value, effective value, PF (power factor). Voltage harmonics measurement capacity is up to 50th. The built-in GPIB, LAN and USB communication interfaces are for reliable and fast control. IT8600 is the perfect solution for testing UPS, inverters, AC power supplies and relevant AC electronic components etc.</p>
<p>The post <a href="https://www.electro-meters.com/product/itech-it8600-series-ac-dc-electronic-loads/">ITECH IT8600 Series &#8211; AC/DC Electronic Loads</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul>
<li>Frequency range: 45 Hz~450 Hz</li>
<li>Power range: 0~14.4 kVA</li>
<li>Voltage range: 50~420 Vrms, 15~260 Vrms</li>
<li>Current range: 0~1 60 Arms</li>
<li>Parallel connection/ three-phase control &sup1;</li>
<li>7’’ LCD screen</li>
<li>Oscilloscope function supporting display of voltage and current waveform</li>
<li>High-speed AD sampling, real-time capture waveform</li>
<li>Measure Vrms, Vpk, Vdc, Irms, Ipk, Idc, W, VA, VAR,CF, PF and FREQ</li>
<li>Measures THD ( V ) up to 50th Harmonic</li>
<li>AC electronic load: CC/CR/CP mode</li>
<li>DC electronic load: CC/CR/CP/CV mode &sup2;</li>
<li>External 0~10 V analog control input, voltage and current analog monitoring function &sup3;</li>
<li>OTP, OCP, OVP, UVP and OPP protection function</li>
<li>GPIB, LAN and USB communication interfaces and external USB flash disk interface</li>
</ul>
<ol>
<li>IT8616 is without this function, IT8617 supports single/three-phase switch output</li>
<li>Only IT8615 and IT8615L are with CV function</li>
<li>Only IT8615 and IT8615L have the function of external analog</li>
</ol>
<p>The post <a href="https://www.electro-meters.com/product/itech-it8600-series-ac-dc-electronic-loads/">ITECH IT8600 Series &#8211; AC/DC Electronic Loads</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
