<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Superior Electric Distributor in Canada &#8211; Electro-Meters</title>
	<atom:link href="https://www.electro-meters.com/manufacturers/superior-electric/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.electro-meters.com/manufacturers/superior-electric/</link>
	<description>Technology for all your measurement needs</description>
	<lastBuildDate>Fri, 29 Apr 2022 14:19:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.electro-meters.com/wp-content/uploads/images/electro-meters/cropped-EMlogo_square-32x32.png</url>
	<title>Superior Electric Distributor in Canada &#8211; Electro-Meters</title>
	<link>https://www.electro-meters.com/manufacturers/superior-electric/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Superior Electric WHR &#8211; STABILINE Automatic Voltage Regulator</title>
		<link>https://www.electro-meters.com/product/superior-electric-whr-stabiline-automatic-voltage-regulator/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Fri, 02 Jul 2021 17:22:55 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=14667</guid>

					<description><![CDATA[<p>Superior Electric offers an extensive line of voltage regulators as part of their WHR Series. WHR Series STABILINE® Automatic Voltage Regulators maintain constant voltage to your equipment, even when the input voltage and system load vary widely.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-whr-stabiline-automatic-voltage-regulator/">Superior Electric WHR &#8211; STABILINE Automatic Voltage Regulator</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Lightning strikes, line disturbances and uneven loads cause disabling transients, spikes, sags and surges. Left unregulated, these conditions will degrade- even destroy sensitive broadcast electronics in receiving stations, studios, mobile production vehicles and transmitter sites. Avoid catastrophic equipment failure, software damage, reduced power tube life and poor signal quality with WHR Voltage Regulators.</p>
<p>STABILINE Automatic Voltage Regulators are designed for use on all AC power systems, up to 660 volts. WHR Series STABILINE Voltage Regulators use standardized control modules, power modules, enclosures, and other options. Control module options include single phase and individual phase control, power circuit options include narrow or wide correction ranges, and enclosure options include floor and rack mount housings. All STABILINE Voltage Regulators are designed and built specifically for regulator use and are currently in operating internationally.</p>
<p>All WHR voltage regulator models utilize our core product technology of special POWERSTAT® Variable Transformers, also uniquely designed for regulator use. POWERSTAT® offers a Limited Range coil design allows for substantially higher current and power ratings without increasing unit size or weight. This is accomplished by utilizing a “limited” portion of the coil windings to provide regulation. The design allows for direct control of the output voltage without the need of secondary devices such as buck/boost transformers and tap switching semiconductors.</p>
<p>STABILINE WHR’s, rated from 2 kVA to 1680 kVA, offer exceptional protection to help broadcast facilities maintain output voltage to ±1% with 99% efficiency. STABILINE regulators automatically feed voltage sensitive equipment a constant voltage level with no waveform distortion, and they have a high overload capacity. Innovative modular construction is key to our ability to offer such a wide variety of regulators with excellent quality, fast delivery and competitive pricing</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-whr-stabiline-automatic-voltage-regulator/">Superior Electric WHR &#8211; STABILINE Automatic Voltage Regulator</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Superior Electric 1296 &#8211; POWERSTAT Variable Transformers</title>
		<link>https://www.electro-meters.com/product/superior-electric-1296-powerstat-variable-transformers/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Wed, 30 Jun 2021 19:45:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=14663</guid>

					<description><![CDATA[<p>The flagship voltage control product offered by Superior Electric, POWERSTAT® Variable Transformers provide a simple, rugged method of controlling electrical voltage, current and power. They take in utility line voltage and provide continuously adjustable output voltage.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-1296-powerstat-variable-transformers/">Superior Electric 1296 &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>This POWERSTAT transformer features POWERKOTE coils for longer life, increased ratings, greater overload capacities and better resistance to fungus, salt spray and other contaminating atmospheres. The commutator of the new POWERKOTE coil is embedded in a high temperature material which holds the windings in place, even under severe overloads. As a result, POWERSTAT variable transformer with POWERKOTE coils provide higher output ratings than ordinary variable transformers. To permit maximum utilization of POWERSTAT variable transformer, output ratings are given for both constant current and constant impedance loads. This transformer is suitable for regulate voltage, speed control, lightning control, motor test stands, power supplies applications.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-1296-powerstat-variable-transformers/">Superior Electric 1296 &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Superior Electric DIN1 Plus &#8211; Transient Voltage Surge Suppressors</title>
		<link>https://www.electro-meters.com/product/superior-electric-din1-plus-transient-voltage-surge-suppressors/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Wed, 30 Jun 2021 19:30:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=14661</guid>

					<description><![CDATA[<ul>
<li>10 or 20 kA Surge Amp Capacity Protection per mode for DC use</li>
<li>20 or 40kA Surge Amp Capacity Protection per phase for AC use</li>
<li>15A and 30A models – Maximum Continuous Operating Current</li>
<li>1Ø, 2-Wire plus Ground, 24, 48, 120 and 250 Volt Models</li>
<li>Ultra Compact, Fail-safe Design</li>
<li>Dual Component-Level Fusing</li>
<li>High-frequency Noise Filtering</li>
<li>Hard-wired via Box Terminals</li>
<li>LED Visual Protection Status</li>
<li>10-Year Warranty</li>
<li>UL and cUL Recognized</li>
</ul>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-din1-plus-transient-voltage-surge-suppressors/">Superior Electric DIN1 Plus &#8211; Transient Voltage Surge Suppressors</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>DIN1 PLUS transient voltage surge suppressors deliver worry-free performance with an innovative and proven technology design. All models provide surge protection against harmful transient voltage and high-frequency noise that exceed the nominal operating voltage of AC and DC critical dedicated loads.DIN1 PLUS Series units respond reliably and repeatedly in less than 1 nanosecond. The fail-safe design incorporates thermal fuse links and TMOVs, and dual Component-Level Fusing (CLF) are standard in each unit.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-din1-plus-transient-voltage-surge-suppressors/">Superior Electric DIN1 Plus &#8211; Transient Voltage Surge Suppressors</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Superior Electric 1156D &#038; 1256D Series &#8211; POWERSTAT Variable Transformers</title>
		<link>https://www.electro-meters.com/product/superior-electric-1156d-1256d-series-powerstat-variable-transformers/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Wed, 30 Jun 2021 19:22:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=14659</guid>

					<description><![CDATA[<p>POWERSTAT® Variable Transformers of the 1156D and 1256D Series are available in single and three phase, manually operated and motor-driven assemblies.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-1156d-1256d-series-powerstat-variable-transformers/">Superior Electric 1156D &#038; 1256D Series &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The 1156D Series operates from 120 volt lines and the 1256D Series from 240 volt lines. The rated output for the 1156D Series is 50 amperes for constant current loads and 55 amperes for constant impedance loads. The 1256D Series is rated at 28 amperes for both constant current and constant impedance loads.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-1156d-1256d-series-powerstat-variable-transformers/">Superior Electric 1156D &#038; 1256D Series &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Superior Electric 116C-216C &#038; 117C-217C Series &#8211; POWERSTAT Variable Transformers</title>
		<link>https://www.electro-meters.com/product/superior-electric-116c-216c-117c-217c-series-powerstat-variable-transformers/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Wed, 30 Jun 2021 19:04:02 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=14656</guid>

					<description><![CDATA[<p>POWERSTAT® Variable Transformers of the 116C and 117C Series operate from 120 volt lines and 216C and 217C Series operate from 240 volt lines. All models feature POWERKOTE coils.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-116c-216c-117c-217c-series-powerstat-variable-transformers/">Superior Electric 116C-216C &#038; 117C-217C Series &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The rated output for constant current loads ls 10 amperes for the 116C Series; 12 amperes for the 117C Series; 3.5 amperes for the 216C Series; and 5 amperes for the 217C Series. For a constant impedance load the maximum rated output current at line voltage is increased to 13 amperes for the 116C Series; 15 amperes for the 117C Series; 5 amperes for the 216C Series and 7 amperes for the 217C Series.</p>
<p>Single, manually operated units have both 3-hole and 4-hole mounting arrangements; all others have the 4-hole mounting. Single units of the 117C and 217C Series and cord-and-plug models of the 116C and 216C Series have dials graduated in volts. Other single units of the 116C and 216C Series and all ganged units have dials graduated 0-100. The angle of rotation from zero to maximum voltage is 317.5°. Open construction models have a letter U suffix in the type number and have the shaft extending from the base end of the assembly for panel mounting. Knobs can also be placed at the radiator end of the assemblies for general utility mounting because the shafts are removable.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-116c-216c-117c-217c-series-powerstat-variable-transformers/">Superior Electric 116C-216C &#038; 117C-217C Series &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Superior Electric 10C-12C Series &#8211; POWERSTAT Variable Transformers</title>
		<link>https://www.electro-meters.com/product/superior-electric-10c-12c-series-powerstat-variable-transformers/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Wed, 30 Jun 2021 18:56:11 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=14654</guid>

					<description><![CDATA[<p>POWERSTAT Variable Transformers of the 10C-12C Series are offered in single and three phase manually operated assemblies. </p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-10c-12c-series-powerstat-variable-transformers/">Superior Electric 10C-12C Series &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The 10C Series units operate from 120V lines and the 12C Series units operate from 240V lines. 10C Series units are rated at 2.25 amperes for constant current loads and 3.0 amperes for constant impedance loads. </p>
<p>When line voltage connected, 12C Series units are rated at 0. 7 ampere for constant current loads and 0,9 ampere for constant Impedance loads. For over voltage connection the output rating for constant current loads is 0.5 ampere in the output range above line voltage but 0.7 ampere in the range from zero to line voltage. All these ratings are for metal panel mounting.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-10c-12c-series-powerstat-variable-transformers/">Superior Electric 10C-12C Series &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Superior Electric 21-22 Series &#8211; POWERSTAT Variable Transformers</title>
		<link>https://www.electro-meters.com/product/superior-electric-21-22-series-powerstat-variable-transformers/</link>
		
		<dc:creator><![CDATA[Tyler]]></dc:creator>
		<pubDate>Wed, 30 Jun 2021 18:43:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.electro-meters.com/?post_type=product&#038;p=14638</guid>

					<description><![CDATA[<p>POWERSTAT® Variable Transformers of the 21-22 Series are of open construction and are primarily designed for back-of-panel mounting.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-21-22-series-powerstat-variable-transformers/">Superior Electric 21-22 Series &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The rated output for the 21 Series is 5 amperes for constant current loads and 7 amperes for constant impedance loads. For the 22 Series, the rated output is 2.25 amperes for constant current loads and 3.25 amperes for constant impedance loads. The 21 Series types operate from 120 volt lines and the 22 Series types from 240 volt lines. The tapping arrangement permits an output voltage range of zero to line voltage or zero to 17 percent above line voltage. Voltage drops for loads less than full load are proportional. Driving torque, d-c resistance per coil maximum core and brush loss when operating under no load are given in the chart found in the datasheet.</p>
<p>All manually operated 21 Series units have a 3 3/4 inch (95.3mm) dial graduated 0-100 and an angle of rotation or 320·from the zero to maximum output voltage. Adjustable shafts can be extended from either end of the units, permitting general utility mounting if desired. In addition to the conventional screw-type method of connection, terminal adapters supplied with the units can be quickly mounted on the terminals for use with push-on connectors or soldered connections.</p>
<p>The post <a href="https://www.electro-meters.com/product/superior-electric-21-22-series-powerstat-variable-transformers/">Superior Electric 21-22 Series &#8211; POWERSTAT Variable Transformers</a> appeared first on <a href="https://www.electro-meters.com">Electro-Meters</a>.</p>
]]></content:encoded>
					
		
		