HCE was established in 1979, with the goal to design and manufacture products for measuring power and its distribution for utilities and industries. HC excels in developing the best, high quality and reliable product and is recognized all over the world.

Showing 1–10 of 13 results

Hsiang Cheng RPA – AC Current Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications.
  • Manufactured to strict compliance IEC 688.
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options.
  • Well-proven applied circuitries, fully ensuring long-term stability.
  • Small sized DIN case for space saving.
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany).
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPF – Power Frequency Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industries’ compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure to meet the requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPPF200 – Power Factor Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure to meet the requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPV – AC Voltage Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPW – Watt Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPWH – WattHour Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng RPWK – Watt/Var Transducers

  • The RP series are DIN-case electrical power transducers designed for general industry applications
  • Manufactured to strict compliance IEC 688
  • The input & output parameters are pre-selected from a wide range of industry compatible signals and other non-stated ranges are available on request or as options
  • Well-proven applied circuitries, fully ensuring long-term stability
  • Small sized DIN case for space saving
  • Protective touch-proof terminals and enclosure meeting requirements of VBG4 & VDE 0106 part 100 (Germany)
  • High performance & stability of less than 100 ppm drift per ºC change
  • High impulse & surge protection of up to 5KV (RMS) meeting IEC 255-4
  • Perfect for mounting on DIN rail

Hsiang Cheng SPA – AC Current Transducers

  • Self – power mode, zero adj. – non required
  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • Rugged steel enclosure of high magnetic immunity
  • Meets IEEE SWC test

Hsiang Cheng SPD – DC Rate Transducers

  • Standard output with 0 to 1 mAdc; Option on request
  • AC 1800V input / output / isolation meets power series requirement
  • Meets IEEE SWC test
  • Dual isolated outputs eliminating ground loop effect (SPD-2 model)

Hsiang Cheng SPK – AC Var Transducers

  • Standard output with 0 to 1 mAdc
  • Accuracy of reading base 0.25% reading + 0.02% ro
  • High magnetic field immunity
  • Meets IEEE SWC test standards