Display |
Scaling: |
Customized to any scaling desired, from linear to specialized Cos Ø, square root distributions, with color applications for visual emphasis and to any desired engineering units. |
Specific accuracies |
Basic Accuracy: |
±5.0% of full scale basic accuracy class. |
Rectifier Type Meters: |
±5% of full scale basic accuracy class. |
|
Position of use: |
Vertical (scale) standard
or to specified angle or position |
Full scale deflection angle: |
85 ° |
Movement: |
Pivot and Jewel |
In this design the coil and pointer are
supported by polished steel pivots at each
end which fit into jewel bearings. Pivot and
jewel meters are recommended for high vibration
environments because of the
mechanism’s inherent stability and strength.
Accuracy and repeatability are almost equal
to the taut-band’s, and good performance
from the pivot and jewel construction is the
reason for its long popularity. |
Case: |
Polycarbonate |
Cover: |
Polycarbonate cover and window. |
General: |
Operating Temp.: |
0 to 40°C (32 to 104°F) |
Storage Temp: |
-10 to 50°C (14 to 50°F) |
Relative Humidity: |
95% (non condensing) |