Yokogawa TA720 Time Interval Analyzers (discontinued)

space
TA720
Characteristics:
  • Maximum Continuous Sampling Rate 80 MS/s
  • Dual Measurement Function
  • Inter-Symbol Interference Analysis Function, Built-in Printer, and GP-IB Interface are all standard
  • Ethernet and PC Card Interface (optional)
Product Description:
space
TheTA720 Time Interval Analyzer has larger memory capacity and is faster than the highly regarded TA520 and TA320. It has a maximum sampling rate of 80 MS/s, and maximum memory capacity of 1024 k samples (in Time stamp mode). In addition, the TA720 has a variety of completely new functions, such as a dual measurement function, inter-symbol interference analysis function, and an optional Ethernet and PC card interface. This time interval analyzer is the ideal analysis tool for jitter analysis of high-speed optical disk signals and recording characteristic evaluations.
space
Features :
  • Continuous Measurement at up to 80 MS/s and Inter-Symbol Interference Analysis with Dual Measurement Function The TA720 Time Interval Analyzer has larger memory capacity and is faster than the highly regarded TA520 and TA320. It has a maximum sampling rate of 80 MS/s, and maximum memory capacity of 1024 k samples (in Time stamp mode). In addition, the TA720 has a variety of completely new functions, such as a dual measurement function, inter-symbol interference analysis function, and an optional Ethernet and PC card interface. This time interval analyzer is the ideal analysis tool for jitter analysis of high-speed optical disk signals and recording characteristic evaluations.
  • High-Speed Continuous Measurement at up to 80 MS/s The TA720 can continuously measure signals as fast as eight times DVD speed. It continuously measures high-speed signals from sources such as fast-rotating CDs and DVDs, and next-generation optical disks without dropping measurements. This makes accurate jitter analysis possible.
  • Dual Measurement Function This function enables two measurements to be done simultaneously. The available measurement combinations are Period A & Period B, Period A & A-to-B time interval, Pulse A & Pulse B, and Pulse A & A-to-B time interval. During optical disk jitter measurement, for example, it is possible to perform two types of jitter measurements (data-data jitter and data-clock jitter).
  • Inter-Symbol Interference Analysis Function With this function, it is possible to extract and analyze data corresponding to set code conditions (such as all T spaces between 3T marks). The distribution of the extracted data and related statistics can also be displayed and compared against all of the data at the same time. When combined with the dual measurement function, the inter-symbol interference analysis function enables even faster jitter analysis through techniques such as extracting data-clock data using pulse width as a condition.
  • Ethernet and PC Card Interface (optional) Data transmitted to the TA720 through an Ethernet connection can be saved to the PC card or shared over a network. In addition, measurement conditions can be set and controls such as starting and stopping measurements can be entered over the network when an Ethernet connection is used.
space
Functions :
space
The TA720 has a variety of functions that are useful in optical disk jitter measurements. These functions can be combined for even greater efficiency in jitter measurements.
  • Hight-Speed (80 MS/s) Continuous Measurement The TA720 contains multiple counter circuits with 25 ps resolution. When these circuits are switched at high speed, the TA720 is capable of time measurement at up to 80 MS/s (12.5 ns period). For example, the TA720 can continuously measure 1-7 modulation signals without dropping data, if the minimum 2T pulse width is 12.5 ns or greater. (Note: This does not apply during dual measurement function)
  • Dual Measurement Function Simultaneous Measurement of Data-Data Jitter and Data-Clock Jitter The dual measurement function can be used to simultaneously measure an optical disk’s data-data jitter and data-clock jitter. In the past, it was necessary to do these measurements separately, so there was a need for steps such as synchronization using an index signal from a spindle motor as a measurement-start control signal. With the TA720, however, these two measurements can be done simultaneously, so data-data jitter and data-clock jitter from the same measurement area are obtained at the same time.
  • Inter-Symbol Interference Analysis Function This function extracts data corresponding to specified conditions, such as jitter for each space length immediately following a 3T mark, and jitter in each space length between one 3T mark and another. This data can be used to analyze the effects of the code on jitter. The inter-symbol interference analysis function is useful for evaluating recording strategies, such as recording power control and phase control, and recording waveforms. The distribution of the extracted data and related statistics can also be displayed and compared against all of the data at the same time. Code length settings that can be selected include arbitrary code length (nT), length shorter than a specified code length (NT>), and length longer than a specified code length (NT<). With these settings, for example, it is possible to measure jitter for each space length immediately following marks which are 6T or longer, and jitter following long recording lengths.
  • Data-Clock Time Difference Jitter Analysis Based on Recording Length Using the Dual Measurement Function and Inter-Symbol Interference Analysis Function in Combination The inter-symbol interference analysis function can be used in combination with the dual measurement function (Pulse A & A-to-B time interval) to extract data-clock time difference data at each recording length (pulse width).
  • Simultaneous Display of Pulse Width Bipolarity  The TA720 can simultaneously display histograms and statistics for both the positive and negative pulse widths. Numerical individual jitter values, distributions (difference between average value and ideal value for each pulse width), and the like can be checked while comparing the positive and negative histograms. In addition, it is possible to display bipolar histograms and statistics.
  • Multi-Window Function This function allows you preset up to 14 windows for simultaneous analysis and display of histograms and statistics in those windows. During dual measurement function, data-data and data-clock histograms and statistics can be displayed at the same time. In cases where the CAV control is used and the data rate changes according to disk position, the auto-window function is useful for automatically adjusting the window setting. This function provides an Estimated T method, in which the clock period is estimated from the average data signal value; and a Measured T method, in which the clock period is measured from the CHB input signal. The clock period is measured to automatically adjust the window position.
  • For Measuring just the Data Part or just the Header Part on and Optical DiskThe TA720 has the following functions for synchronization with the exterior:
    • External Arming
    • External Gate (connector shared with external arming)
    • Inhibit
The inhibit and external arming functions can be used to separate the data part from the header part during jitter measurement. In addition, a block sampling function can be used to divide the internal memory into as many as 1000 blocks (250 blocks during time stamp mode) for data acquisition. In cases where the recording area is small, such as during media material evaluations, the block sampling function can be used to accumulate samples by performing multiple block measurements with a small amount of data in each measurement (block).
pdf_pic Downloads:General Specifications
Ethernet and PC Card Interface (optional):
space
The Ethernet and PC card interface let you access the TA720 from a PC through a LAN in order to download data from the TA720′s floppy drive or PC card. You can also transfer waveform data and screenshots from the TA720 to the PC for saving.
space
FTP Client Function: Save Data and Screenshots to a Network Drive
space
You can save, delete, and copy waveform data and settings on storage media such as the internal floppy drive or a hard drive located on a networked PC or workstation. These operations work the same way as when you handle data on the PC card. In addition, screenshot data can also be saved. The TA720′s FTP client function can be used to save, delete, and copy waveform data and settings on PCs and workstations running the FTP server function.
space
FTP Server Function: Access a Drive on the TA720 from a PC to Download Files from the Internal Floppy Drive or PC Card
space
You can download files from the TA720′s internal floppy drive or PC card to a networked PC or workstation. The TA720′s FTP server function can be used by PCs and workstations running the FTP client function.
space
Setting TA720 Measurement Conditions and Controlling the Start of Measurement
space
The TA720′s Ethernet connector is a 10BASE-T connector. Connect it to your network through a hub or router as shown. A PC can be used to set measurement conditions on the TA720 and control when measurement starts and stops.
space
TA720 Screen Display for Various Types of Analysis
Histogram Display
List Display
Time Variation Display (Dual Measurement Example Shown)
Jitter and Deviation Graph Display
Statistics Display