Yokogawa Electric Corporation
Test and Measurement Instrumentation

IIII [+] High Accuracy Portable Calibrators/Sources/Analyzers
Yokogawa has a complete line of portable instruments including high accuracy measuring and calibrating instruments
- Yokogawa Portable Calibrators/Sources/Analyzers

Yokogawa High Accuracy Portable Calibrators/Sources/Analyzers
High Accuracy
- Measurement & Calibration
- DC Sources
- Pressure Measurement
- Signal Generators
7556 Series
• High Speed• Direct measurement as fast as 2.8 ms
• High Resolution
• Wide operating rangeability
• Full remote controlability
• Software based calibration
GS610 Source Mesure Unit
• Source & Sink operation
• Basic accuracy: ±0.02%
• Sweep output at up to 100μs intervals
• Sweep patterns (linear, logarithmic, and arbitrary)
• Stores up to 65535 points of source measure data in memory
• Easy file operation with the USB storage function
MT220 Series
• High accuracy: ±0.01% of reading• Measurement with DCV and DCA
• 24 V DC output
• Percent Reading
• Error Reading
• Measurement data memory
MT210 Series
• High accuracy: ±0.01% of reading• Wide range of pressures
• Select from three modes
• Percent Reading
• Error Reading
• Multiple outputs & interfaces
MC100 Series
• High accuracy: ±0.05% of reading• Excellent stability
• Low temperature coefficients
• Zero point: ±0.003% of full scale
• Divided output with as many as 20 steps
• Autostep output functionality
MT10 Series
• High Reliabiltiy• Compact
• Accuracy ± (0.04% of rdg + 0.03% of F.S.)
• Data Hold Function
• Carrying case
• Three models: 130 kPa, 700 kPa, 3000 kPa
FG400 Isolated Arbitrary Function Generator
• High accuracy ±(0.05% of full scale)
• Excellent stability provided by silicon resonant sensor
• Low temperature coefficient
• Zero point: ±0.003% of full scale
• Divided output function with as many as 20 steps
MT220 Series
• High accuracy: ±0.01% of reading• Measurement with DCV and DCA
• 24 V DC output
• Percent Reading
• Error Reading
• Measurement data memory
MT210 Series
• High accuracy: ±0.01% of reading• Wide range of pressures
• Select from three modes
• Percent Reading
• Error Reading
• Multiple outputs & interfaces
MC100 Series
• High accuracy: ±0.05% of reading• Excellent stability
• Low temperature coefficients
• Zero point: ±0.003% of full scale
• Divided output with as many as 20 steps
• Autostep output funcionality
MT10 Series
• High Reliabiltiy• Compact
• Accuracy ± (0.04% of rdg + 0.03% of F.S.)
• Data Hold Function
• Carrying case
• Three models: 130 kPa, 700 kPa, 3000 kPa