• YOKOGAWA

Model CL360, (200mA-1000A),
AC Leakage Current Clamp-on Meters

Clamp-on meters capable of measuring up to 1000AAC
(for conductors up to 68 mm in diameter)
Yokogawa CL360 Clamp-on Meters
Features
  • 3 1/2 digit LCD display
  • Mean value display
  • Leakage current measurement with current range from 200mA to 1000A
  • AC and DC output
  • 68mm in diameter of measurable conductor
  • Approved for conformity to safety standards EN 61010-1, EN 61010-2-032 (CAT III 300 V)
cart Please contact a sales person for price and delivery ►►

Applications

  • Preventative maintenance
  • Testing for current leakage on branch circuits
  • Measuring current draw of motors and motor control circuits
  • Measuring Loads

Description

The CL360 Clamp-on meter features a large clamp that can measure conductors up to 69 mm in diameter and a leakage current range from 200mA and a maximum current range of 1000AAC, ideal for regular current measurement and high resolution for leakage detection.
  • Literature
  • Specifications
Literature and Technical Information
pdf icon

Clamp-on Meters – Portable Test Instruments

++ CL360 Clamp-on Meters| Specification sheet
Model: Yokogawa CL360 Clamp-on Meters
Display
Display LCD (Digital display: 3999 counts)
Specific Accuracies
AC Current
AC (200mA/2A/20A) 1.0+2 (50/60Hz)
3.0+2 (40~1kHz)
AC (200A) 1.5+2 (50/60Hz)
3.5+2 (40~1kHz)
AC 1000A (0~500A) 1.5+2 (50/60Hz)
3.5+2 (40~1kHz)
AC (501~1000A) 5.0 (50/60Hz)
10.0 (40~1kHz)
AC Output Accuracy
200mA/2A/20A(0~200mV) 2.0
200A(0~200mV) 2.5
1000A/(0~50mV/0~500A) 3.0
1000A/(50~100mV/501~1000A) 5.0
DC Output Accuracy
200mA/2A/20A(0~200mV) 3.0
200A(0~200mV) 3.5
1000A/(0~50mV/0~500A) 5.0
1000A/(50~100mV/501~1000A) 7.0
General specifications
Method of detection Mean Value
Response Time Approx. 2 seconds
Range Switching Manual-range
Data Hold On all range
Peak Hold On all range
Influence of external magnetic field 15 mA or less in proximity to a 10 mm – diameter conductor carrying 100A
Influence of conductor position 2% or less
Influence of Residual Current 10 mA or less in proximity to a 10 mm-diameter conductor carrying 100A
Safety Standard Conforms EN61010-1, EN61010-2-032
Influence of Residual Current 12 mA or less in proximity to a 10 mm – diameter conductor carrying 100A
Circuit Voltage 300 Vrms or less
Withstanding Voltage 3.7 kV AC for one minute
Auto power-off Approx. 10 minutes
Diameter of measurable
conductor
40 mm at maximum
Environment
Operating temperature: -10 – 50°C
Relative Humidity: 90% RH or less (no condensation)
Dimensions Approx. 129 (W) x 248 (H) x 55 (D) mm
Weight approx. 570 g
Accessories Batteries, carrying case (93031)
User’s manual (IM CL360)
Power Supply 6 LR61 x 1
6F22 (006P) 9V x 1
Battery Life Approx. 60 hours (continuous)