• YOKOGAWA

CA150 Handy Calibrator
Multi-function Hand-held Calibrator

Multi-functional and high-precision calibrators that can be used to calibrate
and test industrial process devices and various electronics equipment)

cart Ordering info ►►

Features

  • Highly accurate within 0.02% of the DC voltage range for source and measure
  • Source and measurement can be performed simultaneously
  • Vertical body with large-screen display
  • Loop power supply function (24 VDC at a load of max 22 mA)
    It is possible to measure current in the mA range while supplying power
  • Sink function
  • Sweep functions that allow 3 types of continuous outputs:
    • Step sweep function
      This function changes the output in a staircase (step) pattern at fixed intervals
    • Linear sweep function
      This function increases (or decreases) the output linearly with respect to the generated value
    • Program sweep function
      This function outputs source setting values stored by the data memory function sequentially in the order they are stored in the memory

Applications

  • Check flowmeter pulse output and field data
  • Calibration, function check Programmable Controllers
  • Operation check for Yokogawa Pressure Transmitters (4-20 mA)
  • Operation check of Temperature Transmitters

Description

Yokogawa’s CA150 Multi-function Portable Calibrator boasts accuracy an of 0.02% of DC V, incorporates an independent 24 DC V power supply for loop check of two wire transmitters, delivers a high response speed with pulsing excitation current which allows the CA150 to accurately calibrate digital temperature transmitters.

IIII [+] Read More

The Handy Calibrator CA150 is a comprehensive source and measure instrument for your calibration and equipment checking needs at maintenance sites. The CA150 can simultaneously source and measure voltage, current, resistance, TC (Thermocouple), RTD (Resistance Temperature Detector) and pulse signals, all in a single unit. In addition, direct keys for function selection make operation smoother and prevent incorrect measurement by erroneous operations

The CA150 Handy Cal’s memory is capable of storing up to one hundred (100) data items, storage date/time, (source/measurement) functions, ranges and generated values/measured values can be stored. It can also save/load setting conditions. Up to 21 data items can be stored. Settings for (source/measurement) functions, ranges, generated values/measured values as well as setting mode conditions. Stored data can be checked on the display of the main unit as well as via communication.

  • Literature
  • Specifications

|||| Click to View Source Specifications

Model: Yokogawa CA150 Calibrator
DCV Range Source Range Accuracy Resolution
100 mV 0 to ±110.000 mV ±(0.02% +10 μV) 1 μV
1 V 0 to ±1.10000 V ±(0.02% +0.05 mV) 10 μV
10 V 0 to ±11.0000 V ±(0.02% +0.5 mV) 0.1 mV
30 V 0 to ±30.00 ±(0.02% +10 mV) 10 mV
DCmA Range Source Range Accuracy Resolution
20 mA 0 to +22.000 mA ±(0.025% +3 μA) 1 μA
mA SINK Source Range Accuracy Resolution
20 mA SINK 0 to -22.000 mA ±(0.025% +6 μA) 1 μA
Resistance Range Source Range Accuracy Resolution
500 Ω 0 to 550.00 Ω ±(0.02% +0.1 Ω) 0.01 Ω
5 kΩ 0 to 5.5000 kΩ ±(0.05% +1.5 Ω) 0.1 Ω
50 kΩ 0 to 55.000 kΩ ±(0.1% +50 Ω) 1 Ω
RTD Output Source Range Accuracy Resolution
PT 100 -200.0 to 850.0°C ±(0.025% +0.3°C) 0.1°C
JPT 100 -200.0 to 500.0°C ±(0.025% +0.3°C) 0.1°C
TC Output Source Range Accuracy Resolution
K 200.0 to 1372.0°C ±(0.02% +0.5°C) 0.1°C
-200.0 to -100.0°C ±(0.02% +0.8°C)
E -200.0 to 1000.0°C ±(0.02% +0.4°C) 0.1°C
-200.0 to -100.0°C ±(0.02% +0.6°C)
J -200.0 to 1200.0°C ±(0.02% +0.4°C) 0.1°C
-200.0 to -100.0°C ±(0.02% +0.7°C)
T -200.0 to 400.0°C ±(0.02% +0.5°C) 0.1°C
-200.0 to -100.0°C ±(0.02% +0.8°C)
N -200.0 to 1300.0°C ±(0.02% +0.5°C) 0.1°C
-200.0 to 0°C ±(0.02% +1.0°C)
L -200.0 to 900.0°C ±(0.02% +0.5°C) 0.1°C
U -200.0 to 400.0°C ±(0.02% +0.5°C) 0.1°C
-200.0 to 0°C ±(0.02% +0.7°C)
R 0 to 1768°C ± (0.02% +1.2°C) 0.1°C
0 to 100°C ± (0.02% +2°C)
S 0 to 1768°C (0.02% +1.2°C) 0.1°C
0 to 100°C ± (0.02% +2°C)
B 600 to 1820°C ± (0.02% +1°C) 0.1°C
600 to 1000°C ± (0.02% +1.5°C)
Hz/Pulse Source Range Accuracy Resolution
CPM 1.0 to 1100.0 CPM ±0.5 CPM 0.1 CPM
100 Hz 1.00 to 110.00 Hz ±0.05 Hz 0.01 Hz
1000 Hz 90.0 to 1100.0 Hz ±0.5 Hz 0.1 Hz
10 kHz 0.9 kHz to 11.0 kHz ±0.1 kHz 0.1 kHz
50 kHz 9 kHz to 50 kHz ±1 kHz 1 kHz

|||| Click to View Measuring Specifications

Model: Yokogawa CA150 Calibrator
DC Voltage Range Accuracy Resolution
500mV to 500.00 mV (0.02%+50µV) 10 μV
5V 0 to5.0000V (0.02%+0.5mV) 0.1 mV
35V 0 to35.000V (0.025%+5mV) 1 mV
DC Current Range Accuracy Resolution
20 mA 0 to20.000mA (0.025%+4µA) 1 μA
100mA 0 to100.00mA (0.04%+30µA) 10 μA
RTD Output Source Range Accuracy Resolution
PT 100 -200.0 to 850.0°C (0.05%+0.6°C) 0.1°C
JPT 100 -200.0 to 500.0°C (0.05%+0.6°C) 0.1°C
Resistance Range Accuracy Resolution
500 Ω 0 to 500.00 (0.055%+0.075Ω) 0.01Ω
5kΩ 0 to5.0000kΩ (0.055%+0.75Ω) 0.1Ω
50kΩ 0 to50.000kΩ (0.055%+10Ω) 1 Ω
Thermocouples Source Range Accuracy Resolution
K -200.0 to 850.0°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
0.1°C
E -200.0 to 1000.0°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
0.1°C
J -200.0 to 1200.0°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
0.1°C
T -200.0 to 400.0°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
0.1°C
N -200.0 to 1300.0°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
0.1°C
L -200.0 to 900.0°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
0.1°C
U -200.0 to 400.0°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
0.1°C
R 0 to 1768°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°
1°C
S 0 to 1768°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
1°C
B 600 to 1800°C (0.05%+1.5°C)/-100°C
(0.05%+2°C)/-100°C
1°C
Model: Yokogawa CA150 Calibrator
Source Unit
Voltage limiter: Approx. 32 V
Current limiter: Approx. 25 mA
Measurement Unit
Voltage terminal:
42 VDC
Current terminal: 120 mA
Loop Power : Single 24 VDC power supply, Fuse: 125 mA/250 V
General Specifications
Battery: 6 AA size alkaline batteries – dedicated NiMH battery (sold separately)
Battery life: Source/measurement
Output of 5 V DC/10 k or more Size AA alkaline batteries
When 6 batteries are used: Approx. 8 hours
When NiMH battery is used: Approx. 10 hours
AC adapter : 100 to 240 VAC, 50/60 Hz, 1.4 A
OUTPUT: 12 VDC, 3 A
Auto power-off: Approx. 10 minutes;
Insulation resistance: Between input terminal and output terminal: 500 VDC, 50 M or more
Withstand voltage: Between measurement terminal and generation terminal: 350 VAC, 1 minute
Dimensions: Approx. 251 x 124 x 70 mm
Weight: Approx. 1000 g (with Batteries)
Operating temperature: 0 to 40°C, 20 to 80%RH (no condensation)
Storage temperature: –20 to 60°C 90%RH or less (no condensation)
Communication: Serial interface: RS232 D-Sub 9-pin connector
Safety: EN61010-1, EN61010-2-030, UL61010-1
CAN/CSA, C22.2 No.61010-1
EMC: EN 61326-1 Class B;EN 55011 Class B Group1
EN 61000-3-2; EN 61000-3-3