Hsiang Cheng® Corp.

Hsiang Cheng Digital Panel Meters

IIII [+] About Hsiang Cheng

Hsiang Cheng manufactures a wide range of digital and relay panel meters for all types of measurement and control applications. These high-accuracy, low cost meters are ideal for OEM applications as well as the most demanding industrial applications.

 
  • Digital Panel Meters
  • Digital Panel Meters
Hsiang Cheng manufactures a wide range of digital and relay panel meters for all types of measurement and control applications. With high accuracy and low cost these meters are ideal for OEM applications as well as the most demanding industrial applications.
III Hsiang Cheng MA, MV Series
Hsiang Cheng MA/MV series

Average Reading AC Current & Voltage Digital Panel Meters

  • Accuracy: 0.25% fs or 5 counts, 3-3/4 series
  • 0.15% fs + 1count, 4-1/2 series
  • Stability: Temperature coefficient < 50 ppm per degree C
  • Long term drift < 0.2% per year
III Hsiang Cheng MAR, MVR Series
Hsiang Cheng MAR/MVR series

True RMS, AC Current & Voltage Digital Panel Meters

  • Accuracy: 0.25% fs or 5 counts, 3-3/4 series
  • 0.15% fs + 1count, 4-1/2 series
  • Stability: Temperature coefficient < 50 ppm per degree C
III Hsiang Cheng MAF, MVF Series
Hsiang Cheng MAF/MVF series

True RMS, AC Current & Voltage Digital Panel Meters

  • Accuracy: 0.02% fs + 1 count)
  • Temperature coefficient: < 20 ppm per degree C change
  • Long term drift < 20 ppm year
  • 4 digits-9999 counts. 5 digits-99999 counts
III Hsiang Cheng MW, MK Series
Hsiang Cheng MW/MK series

Digital Panel Meters AC Watt & Var Meters

  • Accuracy: 0.25% to 0.5% fs depending on model
  • Temperature coefficient: < 60 ppm per degree C change
  • Long term drift < 0.2% per year
  • 3-3/4 digits 3999 counts maximum.
  • 4-1/2 digits 19999 counts maximum
III Hsiang Cheng MWF, MKF Series
Hsiang Cheng MWF/MKF series

Digital Panel Meters AC Watt & Var Meters

  • Accuracy: 0.2% to 0.5% fs depending on model
  • Temperature coefficient: < 80 ppm per degree C
  • Long term drift < 0.2% per year
  • 3-3/4 digits 3999 counts maximum.
  • 4-1/2 digits 19999 counts maximum
III Hsiang Cheng MWH MKH Series
Hsiang Cheng MWH MKH series

Digital Programmable Watthour, Varhour Meters

  • Accuracy: 4% rd ±0.1% (or 0.2% for some models) fs
  • Output pulse: Photocouple isolator, open colector 30V, 50mA max
  • PTxCT Ratio setting of 3 first effective digits, normal range 0-999
  • Temp coeff: < 70 ppm wh version, < 100 ppm varh per degree C
  • Seven digits 9999999 counts maximum
  • Display: 0.3″ super rated LED
III Hsiang Cheng MF Series
Hsiang Cheng MF series

Digital Panel Meters, Frequency Panel Meters

  • Accuracy: 0.02% fs + 1 count
  • Temperature coefficient: < 20 ppm per degree C change
  • Long term drift < 20 ppm year
  • 4 digits-9999 counts. 5 digits-99999 counts
  • Input resistance < 1 Megohoms
  • Display: 0.56″ super rated LED
III Hsiang Cheng MP ML Series
Hsiang Cheng MP/ML series

Digital Programmable Watthour, Varhour Meters

  • Accuracy: 0.5%fs + 0.2°> 20% input current, 0.5%fs + 0.4°>10% input current
  • Temperature coefficient: <50 ppm per degree c, long term drift <0.2% /year
  • Long term drift < 20 ppm year
  • 0.001-0.999 for PF, 0.010-360.0 degree for phase angle
  • Response time Sample rate 1 pf per sec typically
  • Display: 0.56″ super rated LED
III Hsiang Cheng UFA UFV Series
Hsiang Cheng UFA UFV series

True RMS AC Voltage and Current Digital Meters

  • Digital setup for PT, CT ratio and auto range scale
  • AC true RMS conversion
  • Wide auxiliary power range AC / DC 30-250V
  • High overload capability
  • High accuracy of 0.2%
  • 4-1/2 digits
III Hsiang Cheng MEF Series
Hsiang Cheng MEF series

Digital Panel Meters, Process Panel Meters

  • True process dc rate monitor
  • Wide range of DC voltage & current input
  • Scaleable in engineering unit
  • High accuracy of 0.05%
  • Linear DC output or 24V DC power output (optional)
  • Two-wire application
III Hsiang Cheng MDF Series
Hsiang Cheng MDF series

Programmable Process Panel Meters

  • True process DC rate monitor
  • Wide range of DC voltage & current input
  • Voltage sapn 10mV to 400V
  • High accuracy of 0.05%
  • Current span 1 mA to 200 mA
  • Scaleable display from -19999 to +19999C
III Hsiang Cheng MT/MTR Series
Hsiang Cheng MT/MTR series

Thermocouples & RTD Digital Panel Meters

  • True process temperature monitor
  • Thermocouple & RTD input
  • High accuracy of 0.2% fs
  • Optional customer specified output available
  • 0.1 & 1.0 degree resolution
  • 3-3/4 digits of maximum 3999 counts
III Hsiang Cheng MGF Series
Hsiang Cheng MGF series

Digital Panel Meters, Programmable Pressure Panel Meters spacer

  • True process temperature monitor
  • Thermocouple & RTD input
  • High accuracy of 0.2% fs
  • Standard output available per mV per count
  • Optional customer-specified output available
III Hsiang Cheng ME/MDA/MDV Series
Hsiang Cheng ME/MDA/MDV series

Digital Panel Meters,DC Flow Rate Panel Meters

  • Wide input range selection
  • Process monitor & remote indication
  • Available of 3-3/4 & 4-1/2 digits
  • High accuracy of 0.2%
  • Display with super rate LED
III Hsiang Cheng MFR Series
Hsiang Cheng

Digital Panel Meters, Frequency Rate Meters (RPM/Speed/Fluid)

  • True process frequency/rpm/speed rate monitor
  • Wide input sensitivity range from 10 mV to 100V
  • Rangeable of display scale for 4 digital rate setting
  • High accuracy of 0.05%
  • Linear DC output or 24V DC power output (optional)
  • 12 or 24V exciting voltage provided