  Characteristics:  
 
 
  • Compact size
  • Extremely low power
  • Cost effective method of adding analog channels to a data logger.
  • Each CEM20 multiplexes 20 analog channels into one analog channel on the data logger.
 
 
  Applications:  
 
 
 
Building & Construction Industry
  • Concrete cure monitoring Building services
  • Geotechnical
  • Dam monitoring
  • Land Slip
  • Mining
Tunnels Scientific & Research
  • Thermal Profiling
  • Thermistor arrays
  • Static load testing
General Industry
  • Thermal Profiling
  • Oven calibration
  • Refrigeration monitoring
  • Process monitoring
 
 
  Product Description:  
 

space

dataTaker data loggers can easily increase channel capacity by simply adding a Channel Expansion Module (CEM20). Each CEM20 connects 20 universal data logging channels to the dataTaker data logger. A dataTaker CEM20 connects to one analog channel of the dataTaker data logger. This effectively expands the total channel capacity of the DT80 from 15 to 300 analog inputs and the DT85 to an incredible 800 inputs.

 
 
 
Easy Setup:

Connecting a channel expansion module to a dataTaker data logger is very easy. The CEM20 is powered directly from the dataTaker data logger 12V output. Analog output connections of the CEM20 connect to a analog channel of the data logger. See sample wiring diagram shown.

Solid construction and design:

The construction of the CEM20 is similar to the rugged dataTaker DT80 range. The case is made from an anodized aluminum extrusion with powder coated steel end plates. Removable screw terminals provide flexible options for installation and maintenance.

Compatibility:
The dataTaker CEM20 is compatible with the following dataTaker data loggers:
dataTaker DT80 Series 2
dataTaker DT80G Series 2
dataTaker DT85 Series 2
dataTaker DT85G Series 2
 
 
  General Information:  
 
 
|||||||| Click here for General Specifications
DT85 Data Logger
Digital Channels
No. of Channels: 16 analog input channels (expandable to 300*)
one isolated 3-wire or 4-wire input
or two isolated 2-wire inputs
or three common referenced 2-wire inputs.
Two wire with common reference terminal: 48 (expandable to 800*)
Two wire isolated: 32 (expandable to 600*)
Three and four wire isolated: 16 (expandable to 300*)
*Expansion requires optional CEM20
Input Ranges
Fundamental Input Ranges The fundamental inputs that the DT85 can measure are voltage, current, resistance and frequency. All other measurements are derived from these.

Auto-ranging is supported over 3 ranges.

Voltage & Current Full Scale Resolution
Input Ranges ±30 mVdc
±300 mVdc
±3 Vdc
±30 Vdc
±0.3 mA
±3 mA
±30 mA
0.25 μV
2.5 μV
25 μV
250 μV
2.5 nA
25 nA
250 nA
Resistance Full Scale Resolution
Input Ranges 100 Ω
1000 Ω
10,000 Ω
100 Hz
10 kHz
1.5 mΩ
15 mΩ
150.00 mΩ
0.0002 %
0.0002 %
Accuracy
Resistance 5°C to 40°C – 45°C to 70°C
DC Voltage
0.1% 0.35%
DC Current
0.15% 0.45%
DC Resistance
0.1% 0.35%
Frequency 0.1% 0.25%
Channels | Sampling Rate
channels 1 analog input channel
The channel supports: one isolated 3-wire or 4-wire
input, or two isolated 2-wire inputs,
or three common referenced 2-wire inputs.
Resolution 18 bits
Fastest 25Hz
Linearity 0.01%
Common mode rejection: >90dB
Line series mode rejection: >35dB
 
Inputs
Inter-Channel Isolation: 100V (relay switching)
Resolution 100V (opto-isolated)
Input impedance: 100KΩ, >100MΩ
Common mode range: ±3.5V or ±35V on 30V range
Sensor Excitation (Supply)
Analog channel: Selectable 250μA or 2.5mA precision current source, 4.5V voltage source, or switched external supply.
General Purpose: Switchable 12V regulated supply for powering sensors & accessories. (max 150mA)
Analog Sensors
Supports a wide range of sensors including, but not
limited to, those listed below. A wide range of sensor
scaling and linearizing facilities including polynomials,
expressions and functions.
Thermocouples
input: B, C, D, E, G, J, K, N, R, S, T
Calibration standard: ITS-90
RTDs
input: Pt, Ni, Cu
Resistance range: 10Ω to 10KΩ
Thermistors
input: YSI 400xx Series, other types*
Resistance range: <10kΩ**
* Other thermistor types are supported by scaling and calculated channels.
**Resistance range can be increased with the use of a parallel resistor.
Monolithic Temperature Sensors
Types supported: LM34 - 60, AD590, 592, TMPxx, LM135, 235, 335
Strain Gauge and Bridge Sensors
Configurations: ¼ , ½ & full bridge
Excitation: voltage or current
4-20mA Current Loop
  Internal 100R shunt or external shunt resistor
Relay Outputs
  1 latching relay, contacts (max: 30Vdc, 1A)
Digital Channels
Channels: 8 bi-directional channels
Input Type: 8 logic level (max 20/30V)
Output Type: 4 with open drain FET
(max: 30V, 100mA), 4 with logic output.
Counter Channels
Low Speed Counters 8 counters shared with digital inputs.
Low speed counters do not function in sleep mode
Size: 32 bit
Max Count rate: 10 Hz
Dedicated Counter Inputs
Channels: 4 high speed or 2 phase encoder (quadrature) inputs
Size: 32 bit
Max Count rate: 10 Hz
Serial Channels
SDI-12 1 SDI-12 input, shared with digital channel.
The input can support multiple SDI-12 sensors
Generic Serial Sensor
Flexible options to allow data to be logged from a wide range of smart sensors and data streams.
Available ports: Host RS232 Port*
Baud rate: 300 to 115200
*If used as a Serial Sensor channel then the Host Port is not available for other communications
Calculated Channels
Combine values from analog, digital and serial sensors using expressions involving variables and functions.
Functions: An extensive range of Arithmetic, Trigonometric, Relational, Logical and Statistical functions are available.
Alarms
Condition: High, low, within range and outside range
Delay: Optional time period for alarm response
Actions: set digital outputs, transmit message, execute any dataTaker command
Scheduling of Data Acquisition
No. of schedules: 11
Schedule rates: 10ms to days
Data Storage
Internal Storage
Capacity: 128MB = approx 10,000,000 data points
USB Storage
Types: Compatible with USB 1.1 or USB 2.0 drives, e.g. Flash drive
Capacity: Approx. 90,000 data points per megabyte
Communication Interfaces
Ethernet Port
Interface: 10BaseT (10Mbps)
Protocol: TCP/IP
USB Port
Interface: USB 1.1 (virtual COM port)
Protocol: ASCII command
Host RS232 Port
Speed: 300 to 115200 baud (57,600 default)
Flow Control: Hardware (RTS/CTS), Software (XON/XOFF), None
Modem support: auto-answer and dial out
Protocols: ASCII Command, TCP/IP (PPP), Modbus, Serial Sensor
Network (TCP/IP) Services
Command Interface Access the ASCII command interface of the DT85 via
TCP/IP
Web Server Access current data and status from any web browser. Custom pages can be defined. Download data in CSV format. Command interface window. Define mimic displays.
Modbus Server (slave) Access current data and status from any Modbus client (e.g. SCADA system)
FTP Server Access logged data from any FTP client or web browser
FTP Client Automatically upload logged data direct to an FTP server
System
Display and Keypad
Type: LCD, 2 line by 16 characters, backlight
Display Functions Channel data, alarms, system status.
Keypad: 6 keys for scrolling and function execution
Status LEDs: 4 for sample, disk, attention and power
Real Time Clock
Normal resolution: 200μs
Accuracy: ±1 min/year (0°C to 40°C), ±4 min/year (-40°C to 70°C)
Typical Operating Time
Real Time Using 12Vdc external power source
1 second 1 day
5 second 3 day
1 minute 1 month
1 hour 9.5 months
Power Supply
External voltage : 10 to 30Vdc
Internal battery: 6Vdc 1.2Ahr lead acid
Peak Power: 12W (12Vdc 1A)
Physical and Environment
Construction: Powder coated zinc and anodized aluminum
Dimensions: 180 x 137 x 65mm
Weight: 1.5kg (4kg shipping)
Temperature range: –45°C to 70°C *
Humidity: 85% RH, non-condensing
*reduced battery life and LCD operation outside range –15°C to 50°C
 
 
 
 
   
 
  Downloads:  
 