• Eagle Signal Controls

Counters
SX300 Series Preset Counters

Dual setpoints, count Speeds up to 2500 cps [DC Input],
2500 cpm [AC Input]
Eagle Signal Controls SX300 Preset Controler Series

Features

  • NEMA 4 Hosedown Test rated
  • Eight output operating modes programmable for one or both outputs
  • Programmable Early Trip pre-warn operation
  • Time inhibit input
  • LED indicators for output status
  • Setpoint to zero or zero to setpoint cycle progress indication
  • Front panel and remote reset inputs
  • Keypad lock function
  • Nonvolatile memory (NOVRAM) for program and data retention
  • Removable terminal blocks for wiring connections
  • +12 VDC, 75 milliamp sensor power supply

Description

The SX300 Counter is a microprocessor based, 6 digit counter housed in a standard DIN style case (68 mm square cutout). The small case and front bezel require minimal panel space, yet provides large, easy to read 36 inch LED display.
The SX300 Counter is designed for a single direction count input from a solid state sensor or switch. The DC input versions will count up to 2500 counts per second. The AC input version will count up to 2500 counts per minute. Two individually programmable relays provide a wide variety of output combinations to suit most applications.

IIII [+] Read More
The SX300 Counter provides a number of features normally found on larger and more expensive counters. These features are programmed using rocker switches on the back of the unit for simplicity and security
 
  • Literature
  • Specifications

Literature and Technical Information

pdf icon

Digital Preset Counters

SX300 Preset Counter Series

++ SX300 Preset Counters| Brochure (982 MB)
MAX Series, count 6 Digital Preset Counters
Display:
Display: 6 Digit LED Display, .36" high
Decimal Point: User programmable, can be positioned between any of the 6 digits
Main Counter:
Setting Accuracy: ±0.05% of setting or 50 ms, whichever is larger
Repeat Accuracy: ±0.001% of setting or 35 ms, whichever is larger
Programmed Pulse: 0.01 to 99.99 seconds
Reset Time: 15 ms
Power on Response: 200 ms max.
Control Outputs:
Output 1 Modes: ON-Delay, Interval, ONTimed Pulse Output, Timed Pulse and Repeat, Repeat Cycle, ON or OFF Time Cycle First
ON-Delay: Output 1 is energized at the end of the timing cycle
Interval: Output 1 is energized during the timing cycle
ONTimed Pulse Output: Output 1 is energized for a programmable pulse time up to 99.99 seconds at the end of the timing cycle.
Timed Pulse and Repeat: Output 1 is energized for a programmable pulse time up to 99.99 seconds at the end of the timing cycle with the time cycle automatically repeating.
Repeat Cycle, ON or OFF Time Cycle First: Output 1 is energized and de-energized in repeating operation with either the ON or OFF time period first. The time periods are equal length. Unequal length time intervals can be obtained using the Early Trip prewarn output.
Output 2 Modes: Output 2 can be programmed to operate in parallel with Output 1, providing DPDT relay operation form the two SPDT relays, or it can be programmed as an Early Trip prewarn output that is energized at a predetermined time before the end of the cycle. An example of Early Trip prewarn operation with the ON Delay mode for Output 1 is shown here for reference.
Environmental
Operating Temp.: +32° to +122°F (0° to +50°C)
Operating Voltage/Frequency: A6 – 120 VAC, 50/60 Hz
B6 – 240 VAC, 50/60 Hz
Transient Protection: Immune to 2500 volts peak transients up to 50
microseconds in duration
Sensor Power Supply: +12 VDC, 75 milliamps
Output Rating: Relay: 5 amp (resistive), 10 to 264 VAC
Vibration: Unit function is unaffected by 2.5G sinusoidal vibration magnitude in both directions of the perpendicular mounting axes imposed from 10 to 100 Hz
Weight: 2 lb. 14 oz.
Approvals: cULus
Enclosure: Plastic Molded
Dimensions: 72 x 72 (mm)
Cutout: 68 x 68 (mm)