Model AX503 [Cat 2130.07](Triple output, two 0 to 2.5A; 0-30VDC; 2.7-5.5VDC)

space
Model AX503 [Catalog No. 2130.07]  (Triple output, two 0 to 2.5A; 0 to 30VDC; 2.7 to 5.5VDC)
Characteristics:
  • Single, dual and triple 0 to 30VDC / 0 to 2.5A outputs
  • Series and Parallel operation permit 0 to 60V or 0 to 5A output
  • Low noise (<1mV Ripple) and stable linear technology for clean output
  • High efficiency torodial transformers: no fan and low electromagnetic emissions
  • Active protection against overloads, short circuits and overheating
  • Unique variable tracking mode for Master/Salve operation: Slave or Master track proportionally to the original setting
  • Simultaneous display of Voltage and Current
  • Highly visible Green (V) and Red (A) LED displays
  • Compact design for bench tops
  • Designed to EN 61010-1 safety standards
Application:
  • Engineering design labs
  • Production testing
  • Educational labs
  • Quality assurance testing
  • Approval agency testing
  • Repair and calibration labs
Product Description:
space
space
The Model AX503 offers dual 30V outputs with the ability to display both voltage and current for each output. Additionally, the Model AX503 offers a 5V blind output which is adjustable from 2.7 to 5.5V. Dual 30V outputs can be connected in series to provide double the output voltage up to 60V, or they can be connected in parallel providing double the current output up to 5A. The Model AX503 offers a unique master/slave tracking arrangement whereby the ratio between master and slave can be setup on the fly as needed during the test. Adjusting the master voltage causes the slave to track. Adjusting the slave voltage causes the ratio from master to slave to change accordingly. It offers a Coarse and Fine voltage adjustment as well as current limiting adjustment. The Model AX503 is built to provide many years of reliable, precise, easy-to-use operation and will be a welcome addition to any lab, test bench or production line.
space
Specifications:
space
Single Output Model AX503
Technology Linear
Number of Outputs 3
VOLTAGE
Output 1 0 to 30VDC
Output 2 0 to 30VDC
Output 3 (No display) 2.7 to 5.5VDC
Display Resolution 100mV
Accuracy ±0.5% Reading ± 1ct
Ripple ±1mVrms
LINE REGULATION
± 10% Line Voltage ± 0.03% Voltage Reading ± 2mV
LOAD REGULATION
0 to 2.5A ±0.02% Voltage Reading ± 5mV
0 to 5A ±0.2% Voltage Reading ± 10mV
CURRENT
Output 1 0 to 2.5A
Output 2 0 to 2.5A
Output 3 5A max (no adjustment)
Resolution 10mA
Basic Accuracy ±0.5% Reading ± 1ct
Limit Indicator LED, Outputs 1, 2, & 3
Short-circuit Protection Electronic current limitation with voltage shutdown
Overheating Protection Thermal protection
OUTPUT COUPLING
Tracking Output 1: Master / Output 2: SlaveProportional Slave tracking (0 to 100% of Master)
Series Mode 0 to 60VDC / 0 to 2.5A
Parallel Mode 0 to 30VDC / 0 to 5A
GENERAL
Power Source 115VAC ± 10%
Display (LED) Dual Display: VOLTAGE in Green, CURRENT in Red; 0.56″ (14.2mm) digit size
Operating Temperature Range 50° to 104°F (10° to 40°C)
Operating Relative Humidity <80% RH up to 104°F (40°C)
Storage TemperatureRange -4° to 158°F (-20° to 70°C)
Dimensions 10.63 x 8.86 x 4.73″ (270 x 225 x 120mm)
Weight 13.2 lbs (6kg)
SAFETY
Rating EN 61010-1, 100V Cat. I, CE Mark
Power Supply Inputs Overvoltage Cat. 300V Cat. II