Model MR561 [Cat. No. 1200.73] AC/DC Current Probe (BNC)

10mV/A – 150A max & 1mV/A – 1500A max

space
space
AEMC Model MR561 [Cat. No. 1200.73] AC/DC Current Probe (BNC) 10mV/A - 150A max & 1mV/A - 1500A max)
Characteristics:
  • Measurement range of 100AAC/150ADC & 1000AAC/1500ADC
  • Conforms to EN 61010, 600V Cat. III safety standard
  • Low phase shift for power measurements
  • Designed for DMMs, recorders, oscilloscopes, power and harmonic meters
  • Distinct jaw shapes to be used for hooking or prying around the conductor
  • Auto-zero push button
  • Low phase shift for power measurements
  • mV output signals
Applications:
  • DC motors
  • Batteries
  • Automobile engine testing
  • Power measuring quality analysis
  • Power load monitoring
Product Description:
space
space The MR561 is designed for oscilloscopes, waveform displaying instruments, and other frequency sensitive displaying instruments with BNC inputs. The probe has a 6.5 ft (1.98m) lead terminated by a BNC connector.
space
Specifications:
space
MR561
ELECTRICAL
Nominal Range 100AAC/150ADC & 1000AAC/1500ADC
Measurement Range 0.2 to 1500A
Output Signal(s) 150A: 10mV/A1500A: 1mV/A
Accuracy(150ADC Range) 0.5 to 20A 1.5% of Reading ± 0.5A
20 to 100A 1.5% of Reading
100 to 150A 2.5% of Reading
Phase Shift (60ADC Range) 10 to 20A ≤3.0°
20 to 100A ≤2.0°
Accuracy(1500ADC Range) 0.5 to 100A 1.5% of Reading ± 1A
100 to 800A 2.5% of Reading
800 to 1000ADC 4% of Reading
1000 to 1500ADC 4% of Reading
Phase Shift (1500ADC Range) 10 to 200A ≤2.0°
200 to 1000A ≤1.5°
Overload 2kAAC and 3kADC cont. to 1kHz
Frequency Range DC to 10kHz @ -3dB
Load Impedance >100kΩ/100pF max
Working/Common Mode Voltage 600Vrms
Battery 9V Alkaline (Approx. 50 hours life)
Output Termination 6 ft BNC
MECHANICAL
Operating Temperature 14° to 131°F (-10° to 55°C)
Storage Temperature -40° to 176°F (-40° to 70°C)
Operating Relative Humidity 10 to 35°C 90% ± 5% RH (without condensation), 40 to 55°C 70% ± 5% RH (without condensation)
Zero Adjustment Auto-zero
Jaw Opening 1.2″ (31mm)
Maximum Conductor Size One 1.18″ (30mm) or two 0.95″ (24mm) or two bus bar1.2 x 0.4″ (31.5 x 10mm)
Dimensions 8.8 x 3.82 x 1.73″ (224 x 97 x 44mm)
Weight 15 oz (440g)
Polycarbonate Material Handles: Polycarbonate +ABS, Gray, UL94 V0. Jaws: Polycarbonate, Red, UL94 V0
SAFETY
Electrical EN 61010-2-32
Double Insulation Yes
CE Mark Yes
space
MR561 Downloads: Specifications
base
space
The AEMC® MR Series AC/DC Probes are professional AC/DC current probes designed to extend current measuring capabilities of DMMs, oscilloscopes and other instruments. They are built to the latest safety and performance standards, including the CE Mark and UL approval. Two different hook-shaped jaws are offered, both permitting the user to “pry” or “hook” onto cables (will accept 2 x 500MCM) or even onto small bus bars. The MR Series probes use Hall effect technology and measure AC and DC current. The electronics and batteries are self-contained in the handles. The output of the AC/DC probes is 1mV/A and 10mV/A. The Model MR561 measures to 1000AAC/1500AAC. There is no output filtering — True RMS with DC component measurements are possible. Phase shift is excellent, making the MR Series of current probes well suited for power and power quality applications. The Model MR561 is designed for oscilloscopes, waveform displaying instruments and other frequency sensitive displaying instruments with BNC inputs. index mail web