AEMC®Instruments

Model MR521 [Cat No. 1200.69] AC/DC Current Probe (10mV/A – 150A max & 1mV/A 1500A max)

space
space
aemc Model MR521 [Catalog No. 1200.69] AC/DC Current Probe  (10mV/A - 150A max & 1mV/A 1500A max)
Characteristics:
  • Measurement range of 100AAC/150ADC & 1000AAC/1500ADC
  • Conforms to EN 61010, 600V Cat. III safety standard
  • Low phase shift for power measurements
  • Designed for DMMs, recorders, oscilloscopes, power and harmonic meters
  • Distinct jaw shapes to be used for hooking or prying around the conductor
  • Auto-zero push button
  • Low phase shift for power measurements
  • mV output signals
Applications:
  • DC motors
  • Batteries
  • Automobile engine testing
  • Power measuring quality analysis
  • Power load monitoring
Product Description:
space
The MR521 is a general purpose 1500AAC or DC current probe designed for use with DMMs, loggers, oscilloscopes and other instruments that have voltage inputs. The MR521 has dual selectable range probes. The MR521 has an integral 5 ft (1.5m) lead terminated by shrouded banana plugs. The jaw design on these probes make then well-suited for measuring current in both cable and bus bar type conductors.
space
Specifications:
space
MR521
ELECTRICAL
Nominal Range 100AAC/150ADC & 1000AAC/1500ADC
Measurement Range 0.2 to 1500A
Output Signal(s) 150A: 10mV/A1500A: 1mV/A
Accuracy(150ADC Range) 0.5 to 20A 1.5% of Reading ± 0.5A
20 to 100A 1.5% of Reading
100 to 150A 2.5% of Reading
Phase Shift (60ADC Range) 10 to 20A 45 to 65Hz: ≤3°
20 to 100A ≤2.0°
Accuracy(1500ADC Range) 0.5 to 100A 1.5% of Reading ± 1A
100 to 800A 2.5% of Reading
800 to 1000ADC 4% of Reading
1000 to 1500ADC 4% of Reading
Phase Shift (1500ADC Range) 10 to 200A 45 to 65Hz: <2°
200 to 1000A ≤1.5°
Overload 2kAAC and 3kADC cont. to 1kHz
Frequency Range DC to 10kHz @ -3dB
Load Impedance >100kΩ/100pF max
Working/Common Mode Voltage 600Vrms
Battery 9V Alkaline (Approx. 50 hours life)
Output Termination 5 ft Lead
MECHANICAL
Operating Temperature 14° to 131°F (-10° to 55°C)
Storage Temperature -40° to 176°F (-40° to 70°C)
Operating Relative Humidity 10 to 35°C 90% ± 5% RH (without condensation), 40 to 55°C 70% ± 5% RH (without condensation)
Zero Adjustment Auto-zero
Jaw Opening 1.2″ (31mm)
Maximum Conductor Size One 1.18″ (30mm) or two 0.95″ (24mm) or two bus bar1.2 x 0.4″ (31.5 x 10mm)
Dimensions 8.8 x 3.82 x 1.73″ (224 x 97 x 44mm)
Weight 15 oz (440g)
Polycarbonate Material Handles: Polycarbonate +ABS, Gray, UL94 V0. Jaws: Polycarbonate, Red, UL94 V0
SAFETY
Electrical EN 61010-2-32
Double Insulation Yes
CE Mark Yes
space
pdf_pic Downloads: Specifications
space
base
space
General Purpose Probes AC Probes
weblink
index mail web