AEMC®Instruments

Model CA7024 Cable Fault Mapper

(Length Tester, Alphanumeric TDR)

AEMC® Model CA7024 , Cable Fault Mapper®  (Length Tester, Alphanumeric TDR)

Characteristics:

  • Features Hand-held Cable Length Meter and Fault Locator
  • Detect opens & shorts and their distance from one end of the cable
  • Measure cable length up to 6000 ft (2000m) in feet or meters
  • Automatic cable impedance compensation
  • Built-in library of most common cables and their Vp (Velocity of Propagation)
  • Manual selection of Vp for all cables not found in library
  • Vp setting displayed long with length and cable type (if in library)
  • Built-in tone generator for tracing and locating cables
  • Large high-visibility blue electroluminescent backlit display

Applications:

  • Determine length of cables on reels, coils or in boxes
  • Determine cable runs in wall, conduit and other surfaces
  • Detect opens and shorts/trace cables to identify runs
Product Description:
space
Le Fault Mapper® modèle CA7024 est réflectomètre de domaine temporel (TDR) portatif, alphanumérique, aussi bien comme un compteur de longueur du câble et localisateur de défaut, conçu pour mesurer la longueur des câbles électriques et de communication. Il peut également indiquer la distance à un défaut dans le câble (ouvert ou en court), compte tenu de l’accès à une seule extrémité d’un câble à deux conducteurs ou plus.En incorporant la technologie TDR fast-edge steop, le modèle CA7024 mesure la longueur du câble et indique la distance au défaults de circuit ouvert (court-circuits), jusqu’à une distance de 6000 pieds (2000m), sur pratiquement tout type de câble. Le modèle CA7024 indique la longueur du câble (la distance au court-circuit) avec une description, alphanumériquement sur un écran graphique LCD 128 x 64. ***The Model CA7024 incorporates an oscillating tone generator that is detectable with a standard tone receiver, for use in the tracing and identification of cables.
Specifications:
MEASUREMENTS
Range @ Vp =70%
6000 ft or 2000m (user selectable)
Resolution
0.1 to 100 ft, then 1 ft (0.1 up to 100m, then 1m)
Accuracy*
±2% of Reading
Minimum Cable Length
12 ft (4m)
Cable Library
Built-in, user selectable & user programmable
Vp (Velocity of Propagation
Adjustable from 20 to 99%
Output Pulse
5V (peak to peak) into open circuit; nanosecond rise Step Function
Output Impedance
Automatic compensation
Tone Generator
Oscillating tone 810 to 1110Hz
Voltage Warning
Triggers @ >10VAC/DC
GENERAL
Display Resolution
128 x 64 pixel graphical LCD
Display Backlight
Blue electroluminescent
Power Source
4 x 1.5V AA Alkaline batteries
Auto-Off
After 3 minutes
Languages
English, French, German, Spanish, Portuguese, Italian
Battery Life
Standby mode >4000 hrsContinuous testing >7.5 hrs
Storage Temperature
-4° to 158°F (0° to 70°C); 5 to 95% RH non-condensing
Operating Temperature
32° to 112°F (0° to 40°C); 5 to 95% RH non-condensing
Dimensions
6.5 x 3.5 x 1.5″ (165 x 90 x 37mm)
Weight
12 oz (350g)
SAFETY
Safety Ratings
EN 61010-1, EN 60950, EN 61326-1
CE Mark
Yes
pdf_pic Downloads: Specifications
base