Model: Acuvim II Power Meters |
Real Time Metering |
Phase Voltage: |
V1, V2, V3, Vlnavg |
Line Voltage: |
V12, V23, V31, Vllavg |
Current: |
I1, I2, I3, In, Iavg |
Power: |
P1, P2, P3, Psum |
Reactive Power: |
Q1, Q2, Q3, Qsum |
Apparent Power: |
S1, S2, S3, Ssum |
Power Factor: |
PF1, PF2, PF3, PF |
Frequency: |
F |
Load Features: |
Load Features |
Four Quadrant Powers: |
Four Quadrant Powers |
Energy & Demand |
Energy: |
Ep_imp, Ep_exp, Ep_total, Ep_net |
Reactive Energy: |
Eq_imp, Eq_exp, Eq_total, Eq_net |
Apparent Energy: |
Es |
Demand: |
Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3 |
Monitoring |
Power Quality: |
Voltage Unbalance Factor: |
U_unbl |
Current Unbalance Factor: |
I_unbl |
Voltage THD: |
THD_V1,THD_V2,THD_V3, THD_Vavg |
Current THD: |
THD_I1, THD_I2, THD_I, THD_Iavg |
Individual Harmonics: |
Harmonics 2nd to 63rd |
Voltage Crest Factor: |
Crest Factor |
TIF: |
THFF |
Current K Factor: |
K Factor |
Statistics: |
MAX with Time Stamp
MIN with Time Stamp |
Each phase of V & l; Total of P, Q, S, PF & F; Demand of P,Q & S;
Each phase THD of V & I; Unbalance factor of V & I |
|
Alarm: |
Over/Under Limit Alarm |
V, I, P, Q, S, PF, V_THD & I_THD Each Phase and Total or
Average; Unbalance Factor of V & I; Load Type; Analog Input
of Each Channel |
Communication: |
RS485 Port, Half Duplex, Optical Isolated |
Modbus®-RTU Protocol/DNP3.0 Option |
Time: |
Real Time Clock |
Year, Month, Date, Hour, Minute, Second |
Optinal Modules |
I/O OPTION |
Switch Status (DI) |
Digital Input (Wet) |
Power Supply for DI |
24 Vdc |
Relay Output (RO) |
NO, Form A |
Digital Output (DO) |
Photo-MOS |
Pulse Output (PO) |
By Using DO |
Analog Input (AI) |
0(4)~20mA, 0(1)~5V |
Analog Output (AO) |
0(4)~20mA, 0(1)~5V |
Communication: |
Ethernet |
10M/100M, Modbus-TCP, HTTP Webpage, Email |
Profibus-DP |
Profibus-DP/V0 |
BACnet |
IP or MS/TP |
RS485 Module |
Additional Modbus RTU |
|
Accuracy |
Resolution and Range |
Voltage: |
0.2% |
0.1V (20V~1000kV) |
Current: |
0.2% |
0.1mA (5mA~50000A) |
Power: |
0.2% |
1W (-9999MW~9999MW) |
Reactive Power: |
0.2% |
1var (-9999Mvar~9999Mvar) |
Apparent Power: |
0.2% |
1VA (0~9999MVA) |
Power Demand: |
0.2% |
1W (-9999MW~9999MW) |
Reactive Power Demand: |
0.2% |
1var (-9999Mvar~9999Mvar) |
Apparent Power Demand: |
0.2% |
1VA |
Power Factor |
0.2% |
0.001 (-1.000~1.000) |
Frequency |
0.2% |
0.01Hz (45.00~65.00Hz) |
Energy |
0.2% |
Primary – 0.1kWh (0-99999999.9kWh) |
Secondary – 0.001kWh (0-999999.999kWh) |
Reactive Energy: |
0.2% |
Primary – 0.1kvarh (0-99999999.9kvarh) |
Secondary – 0.001kvarh (0-999999.999kvarh) |
Apparent Energy: |
0.2% |
Primary – 0.1kVAh (0-99999999.9kVAh) |
Secondary – 0.001kVAh (0-999999.999kVAh) |
Harmonics: |
1.0% |
0.1% |
Phase Angle: |
2.0% |
0.1° (0.0°~359.9°) |
Unbalance Factor: |
2.0% |
0.1% (0.0%~100.0%) |
Running Time: |
|
0.01h (0~9999999.99h) |
Specifications |
Power Voltage: |
100~415Vac, 50/60Hz; 100~300Vdc 50/60Hz |
Withstand: |
3250Vac, 50/60Hz for 1 minute |
Temperature Range: |
- 25°C to 70°C |
Storage Temperature: |
- 40°C to 85°C |
Humidity Range: |
5% to 95% Non-Condensing |
Dimensions: |
96×96×51mm (92×92 cutout) DIN |
Weight: |
6.4kg(14.1Ib)
With IQ-DSG3000 option 6.7kg(14.8Ib)
|
Compliance: |
Measurement Standard: IEC 62053-22; ANSI C12.20
Environmental Standard: IEC 60068-2
Safety Standard: IEC 61010-1, UL 61010-1, IEC 61557-12
EMC Standard: IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22, IEC 61000-3-2, IEC 61000-6-2/4
Outlines Standard: DIN 43700, ANSI C39.1
|
|
◎- OPTIONAL |
Acuvim |
|
Parameter |
-II |
-IIR |
-IIE |
-IIW |
Real Time Metering: |
Phase Voltage
|
● |
● |
● |
● |
Line Voltage |
● |
● |
● |
● |
Current
|
● |
● |
● |
● |
Power
|
● |
● |
● |
● |
Reactive Power |
● |
● |
● |
● |
Apparent Power |
● |
● |
● |
● |
Power Factor |
● |
● |
● |
● |
Frequency: |
● |
● |
● |
● |
Load Features |
● |
● |
● |
● |
Four Quadrant Powers |
● |
● |
● |
● |
|
Energy and Demand |
Energy |
● |
● |
● |
● |
Reactive Energy |
● |
● |
● |
● |
Apparent Energy |
● |
● |
● |
● |
Demand
|
● |
● |
● |
● |
Time of Use |
Energy/Max Demand |
|
|
● |
|
Daylight Savings Time |
|
|
● |
|
Waveform Capture: |
Voltage / Current Waveform |
|
|
|
● |
Power Quality: |
Voltage Unbalance Factor |
● |
● |
● |
● |
Current Unbalance |
● |
● |
● |
● |
Voltage THD |
● |
● |
● |
● |
Current THD
|
● |
● |
● |
● |
Individual Harmonics |
● |
● |
● |
● |
Voltage Crest Factor: |
● |
● |
● |
● |
TIF: |
● |
● |
● |
● |
Current K Factor |
● |
● |
● |
● |
Statistics: |
MAX with Time Stamp
MIN with Time Stamp |
● |
● |
● |
● |
|
Alarm: |
Over/Under Limit Alarm |
● |
● |
● |
● |
Power Quality Event Logging: |
Sag/Dips, Swell |
|
|
|
● |
Data Logging: |
Data Logging 1
Data Logging 2
Data Logging 3 |
|
● |
● |
● |
Memory (on board): |
Running Time
|
|
8MB |
8MB |
8MB |
Communication: |
RS485 Port, Half Duplex, Optical Isolated |
● |
● |
● |
● |
Time: |
Real Time Clock |
● |
● |
● |
● |
|
I/O: |
Switch Status (DI) |
◎ |
◎ |
◎ |
◎ |
Power Supply for DI |
◎ |
◎ |
◎ |
◎ |
Relay Output (RO) |
◎ |
◎ |
◎ |
◎ |
Digital Output (DO) |
◎ |
◎ |
◎ |
◎ |
Pulse Output (PO) |
◎ |
◎ |
◎ |
◎ |
Analog Input (AI) |
◎ |
◎ |
◎ |
◎ |
Analog Output (AO) |
◎ |
◎ |
◎ |
◎ |
Communication: |
Ethernet |
◎ |
◎ |
◎ |
◎ |
Profibus-DP |
◎ |
◎ |
◎ |
◎ |
BACnet |
◎ |
◎ |
◎ |
◎ |
RS485 Module |
◎ |
◎ |
◎ |
◎ |
|