DAQLOGGER (separately sold software)
PC: PC running Microsoft Windows 95*/98/NT4.0 (Service Pack 3 or later), or Windows 2000 or later**, with: An MMX Pentium 166 MHz or faster processor (Pentium II 300 MHz or faster recommended) and at least 64 MB of RAM (128
MB or more recommended) is required to run the 400-channel model of DAQLOGGER. A Pentium II 300 MHz or faster (Pentium III 400 MHz or faster recommended) and at least 128 MB of RAM (256 MB or more recommended) is required to run the 1000-channel model of DAQLOGGER. A Pentium III 400 MHz or faster (Pentium III 600 MHz or faster recommended) and at least 128 MB of RAM (256 MB or more recommended) is required to run the 1600-channel model of DAQLOGGER. Hard disk: At least 30 MB of free space is required when installing the software. (The free hard disk space needed for data storage depends on the amount of data to be stored.)
Display:
At least 800 x 600 resolution; 32,768 colors (1024 x 768 recommended) CD-ROM drive: A CD-ROM drive supported by your Windows operating system is required for installing the software.
Communication interface:
RS-232-C ports supported by your Windows operating system (the COM1 to COM9 ports can be used).
Ethernet port (when connecting DX, DARWIN or MV via Ethernet)
Printer and pointing device:
A mouse supported by your Windows operating system is required. A printer supported by your Windows operating system is required for printing.
|
|
|
|
|
| |
|
|
| |
| |
|
|
| |
| |
|
|
| |
- MV100 (12 channels max.)
- 5.5-inch, wide viewing-angle, TFT color LCD
- Removable storage on 3.5-inch floppy disk, Zip disk
- PCMCIA ATA flash memory card
- Data collection over Ethernet network (standard)
- E-mail sending function and Web monitoring function
- Network-compatible sophisticated software
- Highly reliable hardware
|
|
|
| |
| |
|
|
| |
| |
MobileCorder
The MobileCorder is an innovative paperless recorder designed for today's networked-data environment, equipped with a FTF color display, Ethernet port and storage media.
The MV100 internal memory can store approx. 27 hours of continuous data, recording at 1-sec. intervals on a 6-channel model, or 8 hours on a 20-channel model. Data capacity can be increased to 1.1 years' worth of continuous data |
|
| |
| |
|
|
|
- Structure
External dimensions:
Approximately 152 (W) x 225 (H) x 240 (D) mm
Weight: Approximately 4 kg
Approximately 281(W)×338(H)×252(D)mm
- Input unit
Input types: Floating unbalanced input, inter-channel isolation (However, a common terminal is used for b terminals of RTDs.)
- Measurement intervals: MV102, MV104: 125 ms
MV106, MV112: 1 second (Measurement interval is 2 seconds when the A/D integrating time is set to 100 ms.)
- Input, measuring ranges, and measurement/display accuracy:
(reference operating conditions: 23 ±2°C; 55 ±10% RH; supply
voltage: 90 to 132, 180 to 250 VAC; supply frequency: 50/60 Hz ±1%; warmup time: 30 minutes or longer; performance under conditions, such as vibrations, which do not affect equipment operations
- Supply voltage: AC power supply: 90 to 132, 180 to 250 VAC
- DC power supply: 10 to 18 VDC
- Supply frequency: 50 Hz ±2%, 60 Hz ±2%
- Ambient temperature: 5 to 40°C
- Ambient humidity: 20 to 80% RH (at 5 to 40°C)
- A/D integration time: Select from 20 ms (50 Hz), 16.7 ms (60 Hz), 100 ms (MV106, MV112), and AUTO (automatic switching between 20 ms and 16.7 ms according to power frequency). When using 12VDC power or the MV100 battery pack, 20 ms is always used as the integration time (no automatic switching).
- Reference junction compensation (RJC): INT (internal)/EXT (external) switching possible
- RJC accuracy: Type R, S, B, W: ±1°C
Type K, J, E, T, N, L, U: ±0.5°C (when measured at 0°C or higher)
- Maximum input voltage: 2 VDC or lower voltage range and thermocouple: ±10 VDC (continuous)
6 V, 20 V, 50 VDC voltage range: ±60 VDC (continuous)
- Input resistance: 2 VDC or lower voltage range and thermocouple: 10 MΩ or greater 6 V, 20 V, 50 VDC voltage range: Approximately 1 MΩ
- Input external resistance:
DC voltage, thermocouple input: 2 kΩ or less
RTD input: 10 Ω or less per line (equal on all three lines)
- Input bias current: 10 nA or less
- Maximum common mode noise voltage: 250 VAC rms (50/60 Hz)
- Common mode rejection ratio: 120 dB (50/60 Hz ±0.1%; 500Ω unbalanced; negative terminal to ground)
- Normal mode rejection ratio: 40 dB (50/60 Hz±0.1%)
- Thermocouple burnout: Sensor ON/OFF switching possible Burnout upscale/downscale switching possible
- Calculation:
Difference calculation: Difference calculation between any channels
Difference calculation range: DCV, TC, RTD
Linear scaling: Scaling range: DCV, TC, RTD
Scalable value: -30000 to 30000
Square root scaling: Scaling range: DCV
Scalable value: -30000 to 30000
- Display unit
Display colors:
Trend and bar graph displays: 12 colors Background: White or black
- Trend display:
Direction: Vertical or horizontal
Number of windows: Switching between 4 (4 groups)
Thickness: 1, 2, or 3 dots
Waveform update rate: 15 or 30 seconds (125-ms measurement interval model only), 1, 2, 5, 10, 20, or 30 minutes, or 1, 2, 4 hours (per div)
- Bargraph display:
Direction: Vertical or horizontal
Number of windows: Switching between 4 (4 groups)
Scale: Can be set in range of 4 to 12.
Horizontal bar graph reference position: End or center
Update rate: 1 second
- Digital display: Update rate: 1 second
- Overview display: Measurement values and alarm statuses on all channels
- Information display: Alarm summary, message summary, memory information, media information, etc.
- Other displayed information:
Memory status, scale values (0, 100%, center scale display ON/
OFF switching capability) Grid (AUTO grid setting, or set number of segments between 4 and 12) and hours : minutes Time (year / month / date, hours : minutes : seconds), Trip line (thickness: 1, 2, or 3 dots), Messages (maximum 16 characters, up to 8 types), alarm marks
- Data reference function:
Data can be played back from internal memory or a removable storage medium.
Display types: Split screen (divided in 2) or whole screen
Time axis operations: Zoom-in/-out display, scrolling Storage functions
- Removable storage drive: A drive for the following types of media can be selected when you place your order:
• 3.5-inch floppy disk (2HD)
• Zip disk
• CompactFlash memory card
- Data saving method: Manual saving or auto-saving
- Manual saving: Saves data when a removable storage medium is inserted.
- Auto-saving: Saving display data: Saves data to a removable storage medium periodically (every 10 minutes to 31 days); Saving event
data: Saves data to a removable storage medium periodically (every 3 minutes to 31 days) (when trigger is not yet specified).
Or saves data when sampling period ends (when trigger is specified).
- Auto-saving at set times: This function automatically saves data at times set in advance. It is used together with the auto-save period setting.
- Data saving intervals: Display data files: Interval varies according to the waveform update rate.
Event data files: Sampling interval is specified.
Event data file sampling intervals:
MV102, MV104: 125, 250, 500 ms, 1, 2, 5, 10,
30, 60, 120, 300 or 600 seconds
MV106, MV112: 1, 2, 5, 10, 30, 60, 120, 300 or 600 seconds
- Measurement data files:
The following two types of files can be created:
(1) Event data files (to save instantaneous values sampled at specified sampling intervals)
(2) Display data files (to save maximum and minimum values occurring in display update interval in measurement data sampled at measurement interval)
The two file types can be combined as follows:
(1) Event data file (trigger only) plus display data file
(2) Display data file only
(3) Event data file only
- Data format: Yokogawa standard format (binary format)
- Per-channel data: Display data: Measurement data: 4 bytes per data
- Calculation data: 8 bytes per data
- Event data: Measurement data: 2 bytes per data
- Calculation data: 4 bytes per data
- Sampling time: Example sampling times (MV106, 6 measurement channels, 0 calculation channels)
Alarm functions
- Maximum number:
A maximum of four alarms can be set on each channel.
- Alarm types:
High-low limits, High-low difference limits, rate-of-change increase/ decrease limits, delay upper/lower limits (alarm delay) Rate-of-change alarm time interval: Measurement interval×1 to 15
- Display:
Status (alarm type) and common alarm display in digital display area when alarm occurs Hold/no hold switching capability
- Hysteresis: ON (0.5% of display span)/OFF switching (common to all channels/ levels)
- Outputs: 2, 4, 6, 12, or 24 (12 and 24 can be specified for MV200 only) Operation excitation/no excitation, hold/no hold switching capability
- Storage: Stored information: Alarm occurrence/clear time, alarm type Number of saved items: Maximum 120 (most recent)
|
|
| |
| |
|
|
|
| |
Accuracy |
| DCV |
20 mV |
-20.00 to 20.00 mV |
±(0.1% of rdg + 2 digits) |
| 60 mV |
-60.00 to 60.00 mV |
| 200 mV |
-200.00 to 200.00 mV |
| 2 V |
-2.000 to 2.000 V |
| 6 V |
-6.000 to 6.000 V |
| 20 V |
-20.00 to 20.00 V |
| 50 V |
-50.00 to 50.00 V |
±(0.1% of rdg + 3 digits) |
| TCs |
R*1 |
0.0 to 1760.0°C |
±(0.15% of rdg + 1°C)
R, S: 0 to 100°C, ±3.7°C; 100 to 300°C, ±1.5°C B: 400 to 600°C, ±2°C; if less than 400°C, accuracy is not guaranteed. |
| S*1 |
0.0 to 1760.0°C |
| B*1 |
0.0 to 1820.0°C |
| K*1 |
-200.0 to 1370.0°C |
±(0.15% of rdg + 0.7°C)
If -200 to -100°C, then
±(0.15% of rdg + 1°C) |
| E*1 |
-200.0 to 800.0°C |
±(0.15% of rdg + 0.5°C) |
| J*1 |
-200.0 to 1100.0°C |
±(0.15% of rdg + 0.5°C)
If -200 to -100°C, then
±(0.15% of rdg + 0.7°C) |
| T*1 |
-200.0 to 400.0°C |
| N*1 |
0.0 to 1300.0°C |
±(0.15% of rdg + 0.7°C) |
| W*2 |
0.0 to 2315.0°C |
±(0.15% of rdg + 1°C) |
| L*3 |
-200.0 to 900.0°C |
±(0.15% of rdg + 0.5°C)
If -200 to -100°C, then
±(0.15% of rdg + 0.7°C) |
| U*3 |
-200.0 to 400.0°C |
| RTD*5 |
Pt100*4 |
-200.0 to 600.0°C |
±(0.15% of rdg + 0.3°C) |
| JPt100*4 |
-200.0 to 550.0°C |
| DI |
Voltage input |
OFF: Less than 2.4 V
ON: 2.4 V or greater |
|
| Contact input |
Contact ON/OFF |
|
| |
| |
*1 R, S, B, K, E, J, T, N: IEC584-1 (1995), DIN IEC584, JIS C 1602-1995
*2 W: W-5%, Rd/W-26%, Rd (Hoskins Mfg. Co.) ASTM E988
*3 L: Fe-CuNi, DIN43710, U: Cu-CuNi, DIN43710
*4 Pt100: JIS C 1604-1997, IEC751-1995, DIN IEC751-1996,
JPt100: JIS C 1604-1989, JIS C 1606-1989
*5 Measuring current: i = 1 mA |
|
|
| |
|
|
| |
| |
|
|
|
|
 |
 |
|
|
|
|