- Crisp color analog recording
- 1,2,3,4 pens available
- Wealth of digital printing and analog recording functions
- IC memory card(st'd), FDD(option)
- 3.5-inch floppy disk drive (option)
- Windows (32-bit) application software
- 1600mm/s Maximum Pen Speed
- Intelligent Input Modules
- Universal Inputs
- Flat bed design
|
|
|
| |
| |
|
|
| |
| |
The best-selling LR Recorder Series has revolutionized the pen recorder world with its outstanding reliability and performance. How was it done? Electrical contacts and gears were eliminated in the recording mechanism. Data processing was digitized. A full range of models of up to 12 pens was developed. A memory function to facilitate PC-based data recording and analysis was created. And a whole range of application software was written. In today's PC-driven world, only the LR recorder truly delivers the required functionality. |
|
| |
| |
| |
|
|
|
| |
- Crisp color analog recording in up to 12 colors
As simple to use as an analog pen recorder
The LR series offers easy dialog-based operation on a large vacuum-tube fluorescent display and multiple display functions.
- Wealth of digital printing and analog recording functions
Packed with a wealth of digital printing functions, including zone recording, partial compression and enlargement recording, a rapid pen response of 1600 mm/s and a phase synchronization function, the LR series captures the target event faithfully, records it, and makes playback a cinch.
- Multiple measurement type
The LR series offers DC voltage, thermocouple, and RTD universal inputs, computation functions, IC memory card, a 3.5-inch FDD, and application software to cover every type of measurement.
- 3.5-inch floppy disk drive (option)
- Windows (32-bit) application software
Yokogawa's genuine software lets you set the measurement range and recording conditions, control the motion of the pen such as pen up/down, and even record and analyze the data on a PC.
- 1600 mm/s Maximum Pen Speed
For the fastest possible response, YOKOGAWA developed new proprietary technologies for the LR Series, and raised the maximum pen speed to 1600 mm/s, nearly twice that of the previous fastest.
In terms of frequency response, this equates with nearly 3 Hz at full deflection and 6 Hz at small deflections. High-speed signals are thus recorded faithfully.
- Disposable Felt-tipped Pens
The recording pens of the LR series are special disposable felt-tipped pens with a long thin pen arm and a wide ink storage section, to enable the pens near the back of the instrument to be more visible. These pens have the same high-speed response and long life.
- Auto Sweepout of Pen Offset Data
When you use pen offset compensation, the recorder stores data to compensate for the pen offsets in order to record all traces in real-time. Thus when recording stops, the pens must continue recording until all the data is plotted. Auto sweepout saves you time by automatically increasing the chart speed during this interval - a real advantage at slow chart speeds. For example, at 10 mm/h chart speed on an 8-pen LR, it would take nearly three hours after measurement to record all the stored offset data. In the current LR Series recorders, however, touching the chart stop key automatically increases the chart speed to 200 mm/min and stops it after all pen offset data have been swept out. This takes just eight seconds. This new function, not available on previous LR recorders, has been added at the request of many users.
|
|
| |
| |
|
|
|
| |
| Printout Types |
TAG No. print: User-set tag can be printed in place of channel number (7 characters max.)
Alarm print: Channel number, alarm type, ON/OFF time
Scale print: Prints 0% and 100% scale values at same interval as for periodic print.
Change of chart speed print: Prints time and post-change chart speed when chart speed changes.
List print: Prints all setup information (ranges, alarms, etc.) on chart.
Manual print: Prints time and measured values of all channels on one line when MANUAL PRINT key is pressed.
Message print: Prints user-defined messages up to 70 characters long, with time.
MESSAGE (0): Printed when MANUAL MESSAGE key is pressed.
MESSAGE (1 to 4): Provided with REMOTE option; printed on reception of external contact input (4 points max.)
Change of range print: Prints time and change when range changes in auto span shift mode.
Pen offset compensation ON/OFF print: Prints time and pen offset compensation ON/OFF mark when pen offset compensation is turned ON or OFF.
Periodic print: Prints time, chart speed, channel No. (TAG), measured data, and units at fixed intervals. |
| Display |
Fluorescent display (5 ´ 7 dot, matrix). 20 characters per channel |
Measurement Accuracy DC voltage:
±(0.05% of rdg +0.03% of range +1.0 mV)* |
DC voltage: (at 23±2°C, 55±10% R.H.)
Thermocouples:
R, S ±(0.05% of rdg +1°C) Below 100°C ±3.7°C 100 to 300°C: ±1.5°C
B ±(0.05% of rdg +1°C) 400 to 600°C: ±2.0°C
(not guaranteed below 400°C)
K, E, T, L, U ±(0.05% of rdg +0.5°C)
J ±(0.05% of rdg +0.5°C) -200 to 100°C: ±0.7°C
N ±(0.05% of rdg +0.5°C)
KPvsAu7Fe ±(0.05% of rdg +0.5°C) (not guaranteed below 4 K or above 280 K)
RTD: Pt100, JPt100, Ni100 ±(0.05% of rdg +0.2°C)
Pt50, J263*B ±(0.05% of rdg +0.3°C) |
| Display Modes |
(1) Digital data display: 7-digits measured value (sign, measurement data, unit, decimal point, alarm status), time, chart speed *(2) Bar graph display (2.5% resolution)*
(3) Range data display (zero, span)* (4) Digital data display for all channels
Any of (1), (2), or (3) can be selected with the DISPLAY SELECT key.* |
| Alarm |
Number of levels: 2 levels/channel: Types: High, low, delta high, delta low.
Outputs (optional): internal points, all with 24 V AC, 1 A contact rating |
Computation |
(1) Scaling Input voltage range: Must be within measurement range. Scaling range: –22000 to +22000 (user-set decimal point)
(2) Difference computation Between any two channels set to the same range code |
| IC Memory Card |
Setup data memory (standard) Memory capacity: 8 KB (with lithium battery, life approx. 5 years) *Cannot be specified with suffix code/FDD
at the same time .
Setting life storage capacity: Approx. 5 files |
| Chart End Output |
When chart end is reached, “CHART” LED (red) lights, pens lift, and recorder is placed in monitor status (relay outpt is optional). |
| Option functions |
General purpose communication function (GP-IB, RS-232C) and alarm output relay (10 make contacts)
DI/DO functions (recorder action control function, fail function, chart end function), etc. |
| Clock |
With calendar function |
| Memory Backup |
Internal lithium battery for memory backup (life approx. 10 years at room temperature) |
| Operating Environment |
0 to 40°C, 30 to 80% R.H. (5 to 40°C, 30 to 80% R.H. if suffix code/FDD is specified) |
| Recommended Calibration Conditions |
For measurement ranges less than 1 mV: 6 months For measurement ranges not less than 1 mV: 12 months (environment with proper ventilation and at 23±5°C) |
| Withstanding Voltage |
1,500 V AC between power supply and case for 1 minute |
| Insulation Resistance |
100 Mohm min. at 500 V DC between power supply and case, and between input terminals and case |
| Power Supply |
Allowable power supply voltage: 90 to 132 V AC/180 to 250 AC 48 to 63 Hz. Rated power supply voltage: 100 to 120 V AC/200 to 240 V
AC, 50/60 Hz (universal power supply) |
|
|
| |
|
|
| |
| |
|
|
|
|
 |
 |
| |
Related urls: |
|
|
- LR12000, Vertical Portable Pen Recorders with 10 or 12 pens
- LR8100, Vertical Portable Pen Recorders with 4,6 or 8 pens
- LR4200, Flat bed Pen Recorders with 1,2,3 or 4 pens available
- LR4100, Vertical Portable Pen Recorders with 1,2,3 or 4 pens
- 3057, compact, dependable 150 mm portable Pen Recorder
|
| |
|
| |
|
|
|
|