|
|
|
| |
|
| |
|
|
| |
|
|
|
|
| |
| |
- Long wavelength measurement capability
Long Wavelength 1200 nm to 2400 nm. The AQ6375 covers not only
telecommunication wavelengths,but also the long wavelength
region which is used for environmental sensing, medical,
and industrial material applications.
- High Sensitivity +20 dBm to -70 dBm
The AQ6375 can measure optical
power as low as -70 dBm, which
enables measurements of low
power sources or low power
output of a device under test.
Measurement sensitivity can be
chosen from seven categories
according to test applications and
measurement speed
requirements.
- High Resolution & Wide Dynamic Range
The AQ6375 uses a double-pass monochromator structure to
achieve high wavelength resolution (0.05 nm) and wide close-in
dynamic range (55 dB). Thus, closely allocated signals and noise
can be separately measured.
High Speed Sweep With proprietary sweep technique the AQ6375 achieves a much faster sweep
speed than conventional measurement systems which use a monochromator.
Max. sweep time is only 0.5 sec. in 100 nm span. Fast Command Processing and Data Transfer Applying a fast microprocessor, the AQ6375 achieves very fast command
processing speed and Ethernet provides up to 100 times faster data transfer
speed than the GP-IB.
Applicable fiber: SMF and MMF
The AQ6375 uses a free space input structure, not
having an optical fiber inside the monochromator, that
can handle multimode fibers. The free space input is also
beneficial for measurement repeatability.
The AQ6375 comes with the built-in calibrator for wavelength calibration and
optical alignment adjustment of the monochromator in order to maintain accurate
measurements. The calibration and adjustment are automatically performed and
completed within a couple of minutes.
Wavelength Calibration Calibrates with the designate absorption line of Acetylene gas.
Optical Alignment Adjustment Corrects mechanical movements inside the monochromator caused by shock and
vibration.
- Remote operation (GP-IB, RS-232, Ethernet)
- USB for mouse, keyboard, and memory
|
| |
| |
|
|
|
| |
| |
- Lasers
- Passive optical devices
- Optical fiber
- For Gas sensing
- Medical
- Free-space communications
- Optical fiber communications
|
|
| |
| |
|
|
|
| |

|
The AQ6375 is the first bench-top optical spectrum analyzer covering the long wavelength over 2 μm.
It is designed for researchers and engineers who have been struggling with inadequate test equipment to measure in these long wavelength ranges.
The AQ6375 achieves high speed measurements with high accuracy, resolution and sensitivity in a compact frame,. The AQ6375 provides full analysis features and a built-in calibrator; troublesome calibration steps and the development of external analysis software is no longer required.
Those features are indispensable to research, development, and manufacturing of optical devices in the wavelength range from telecom band to 2 μm.
|
|
|
| |
| |
|
|
|
| |
| |
|||||||| Click here for Standard Functions
| |
| nm / THz / cm-1 |
| Multiple choices of x-axis indication. |
| Various Analysis Functions |
| Thirteen types of built-in analysis functions are available for popular applications. The analysis can be automatically performd and provide results. The functions include: Spectral width, Notch, SMSR, DFBLD, OSNR, EDFA, Filter, and more. |
| 7 Traces & Calibration Functions |
 |
The AQ6375 has seven individual traces for
measurement data. Some traces can be used for
calculations (subtraction between traces), max/min
hold, averaging, etc. |
| Easy Operation |
| Intuitive Operation |
| The AQ6375 inherits our intuitive front panel design from our conventional models for proven easy use and operation. |
| Mouse and Keyboard Operation |
| You can easily operate the AQ6375 with only a mouse instead of the front panel keys. The keyboard is useful for entering labels and file names. The front panel key menu appears when right-clicking the mouse. |
| Trace Zoom Capability |
| Trace zoom makes it possible to change display conditions, such as center wavelength and span, by clicking and dragging the mouse to select the designated area to enlarge. |
| Overview Window |
| Once the trace is zoomed in, the overview window appears and shows the entire trace. By dragging the zoomed area border in this window with the mouse, the display area in the main trace window can be modified. |
| USB & Internal Data Storage |
| USB Storage |
| The AQ6375 has two
USB 1.1 compatible
interfaces that support
large size removable
memory devices such
as Flash ROM and hard
disk drives (HDD). |
| Large Internal HDD Storage |
| The internal storage can save test setups,
waveforms, analysis results, and macro program
files. It is large enough to save more than five
thousand traces. |
| Thumbnail File Preview |
| The Thumbnail file preview function makes it easy
to find a particular file out of thousands of files in
internal and external storage. |
|
|
| |
|||||||| Click here for Standard Features
| Building Automated Test Systems |
| The AQ6375 is equipped with GP-IB, RS-232, and Ethernet (10/100Base-T) interfaces to be connected with
an external PC for remote access and building an automated test system. Macro Program is a useful built-in
function for making a simple auto test program. |
| Compatible with SCPI |
| The standard remote commands of the AQ6375 are
compatible with SCPI, which is an ASCII text based
standard code and format that conforms to IEEE-
488.2. |
| AQ6317 Emulation Mode |
| The AQ6375 supports private remote programming
codes of Yokogawa's best selling AQ6317 series for
users to easily upgrade from their current
automated test environment.
(Note. some commands may not be compatible due to changes
in specifications and functions.) |
| Macro Programming |
| Macro programming enables user to easily create
test procedures by recording the user’s actual key
strokes and parameter selections. An external PC is
not required because the macro program can also
control external equipment through the remote
interfaces. |
AQ6375 Viewer
Emulation and Remote Control Software (Optional) |
 |
AQ6375Viewer is PC application software designed to work with Yokogawa’s AQ6375 Optical Spectrum Analyzer. |
| Emulation |
| The software has exactly the same user interface
and functions as the AQ6375 so that you can easily
display and analyze waveform data. |
| Remote Control |
| \Allows to control AQ6375 from anywhere on the
Ethernet network. Because of fast data transfer
speed of Ethernet, measurement data can be
updated in real time.
Note. the data update speed varies depending on network
performance and conditions. |
|
| |
|||||||| Click here for General Specifications
| AQ6375 Spectrum Analyzer |
| |
| Applicable fiber |
SM (9.5/125 μm),
GI (50/125 μm, 62.5/125 μm) |
| Measurement
wavelength range 1) |
1200 to 2400 nm |
| Span1) |
0.5 nm to full range and zero span |
| Wavelength accuracy 1), 2), 3) |
±0.05 nm (1520 to 1580 nm)
±0.1 nm (1580 to 1620 nm)
±0.5 nm (Full range)
|
| Wavelength repeatability 1), 2) |
±0.015 nm (1 min.) |
| Measurement data point |
101 to 50001 |
| Wavelength resolution
setting 1), 2) |
0.05, 0.1, 0.2, 0.5, 1.0 and 2.0 nm |
| Level sensitivity setting 10) |
NORM_HOLD, NORM_AUTO, NORMAL,
MID, HIGH1, HIGH2 and HIGH3 |
Level sensitivity 2), 4), 5), 7) (Sensitivity: HIGH3)
|
-62 dBm (1300 to 1500 nm)
-67 dBm (1500 to 1800 nm, 2200 to 2400 nm)
-70 dBm (1800 to 2200 nm) |
| Level accuracy 2), 4), 5), 6) |
±1.0 dB (1550 nm, input level: -20 dBm,
sensitivity: MID, HIGH1, HIGH2, or HIGH3) |
| Level linearity 2), 4) |
±0.05 dB (Input level: -30 to +10 dBm,
sensitivity: HIGH1, HIGH2 or HIGH3) |
| Maximum input power 2), 4) |
+20 dBm (Per channel, full span) |
| Safe max. input power 2), 4) |
+25 dBm (Total safe power) |
Close-in dynamic range
1,) 2), 9) |
45 dB (Peak ±0.4 nm, 1523 nm, resolution 0.05 nm)
55 dB (Peak ±0.8 nm, 1523 nm, resolution 0.05 nm)
|
| Polarization dependency 2), 4), 6) |
±0.1 dB (1550 nm) |
| Sweep time 1), 7), 8) |
NORM AUTO: 0.5 sec, NORMAL: 1 sec,
MID: 10 sec, HIGH1: 20 sec |
| Data Storage |
| Internal memory |
64 Traces, 64 programs, 3 template lines |
| Internal storage |
Max. 128 MByte |
| External |
USB storage (memory/HDD),
FAT32 format |
| File type |
CSV(text)/Binary, BMP/TIFF |
| Interface |
| Remote control |
GP-IB, RS-232 and Ethernet (TCP/IP)
AQ6317 series compliant commands
(IEEE488.1) and IEEE488.2 full support |
| Category |
GP-IB 2 (standard/controller), RS-232,
Ethernet, USB1.1 2, PS/2 (keyboard),
SVGA output, Analog output port, Trigger
input port, Trigger output port |
| Optical connector |
Optical input port (free-space): AQ9447 (*)
connector adapter required
Calibration output port (physical contact):
AQ9441 (*) connector adapter required |
| |
Printer
|
Built-in high-speed thermal printer (Factory option)
|
| Display 12) |
10.4-inch color LCD (Resolution: 800 600)
|
Power requirement
|
100 to 240 VAC, 50/60 Hz, approx. 150 VA
|
| Environmental conditions |
Operating temperature: +5 to +35°C
Storage temperature: -10 to +50°C
Humidity: 80 %RH or less (no condensation)
|
| Dimensions and mass 11) |
Approx. 426 (W) 221 (H) 459 (D) mm,
Approx. 27 kg (without printer option) |
Note:
- Horizontal scale: wavelength display mode
- At 23±5°C, with 9.5/125 μm single mode fiber, after 2 hours of warm-up, after optical
alignment with built-in reference light source
- After wavelength calibration with built-in reference light source, sampling interval: 0.003 nm or
less, sensitivity: MID, HIGH1, HIGH2, or HIGH3
- Vertical scale: absolute power display mode, resolution setting: 0.1 nm or greater
- With 9.5/125 μm single mode fiber (B1.1 type defined on IEC60793-2, PC polished, mode
field diameter: 9.5 μm, NA: 0.104 to 0.107)
- Temperature condition changes to 23±3°C for resolution 0.1 nm
- Pulse light measurement mode: OFF, TLS sync sweep: OFF
- Span: 100 nm or less, sampling point: 1001, number of average: 1
- Sensitivity: HIGH 1, HIGH2, or HIGH3
- Automatically goes to CHOP mode when HIGH1, HIGH2, or HIGH3 is selected
- Excluding protector and handle
- Liquid crystal display may include few defective pixels (within 0.002 % with respect to the total number of pixels including RGB). There may be few pixels on the liquid crystal display that do not emit all the time or remains ON all the time. Note that these are not malfunctions.
|
|
| |
|||||||| Click here for Functions
| AQ6375 Functions |
| |
Automatic measurement
|
Macro program function
(64 programs, 200
steps) |
Setting of measuring
conditions
|
- Averaging number setting (1 to 999 times)
- Automatic measuring condition setting
- Sweep between line markers
- Zero span sweep (0 nm span)
- Automatic measurement data point setting
- Pulse light measurement
- External trigger measurement
- Sweep trigger
- Sweep status output
- Analog output
- TLS synchronized sweep
- Air/vacuum wavelength measurement
- Pass/Fail judgment with template
|
Display
|
- Level scale (0.1 to 10 dB/div. and linear)
- Vertical sub scale (0.1 to 10 dB/div. and linear)
- Reference level and position
- Vertical division number (8, 10 or 12)
- Horizontal scale: wavelength (nm)/ wave
number (cm-1)/ frequency (THz)
- Horizontal scale zoom in/out
- Measurement condition display
- Noise mask
- Data table
- Label
- Split display
- Power spectral density (dB/nm) display,
dB/km display, % display
- Template display
|
Traces
|
- 7 independent traces
- Write/Fix, Display/Blank setting
- Max./Min. hold
- Calculation between traces
- Roll (Sweep) averaging (2 to 100 times)
- Normalize
- Curve fit/Peak curve fit/Marker curve fit
- Trace copy/ clear function
|
Marker/Search
|
- Marker: Delta marker (Max. 1024),
Vertical/Horizontal line marker
- Search: Peak, Next peak, Bottom, Next
bottom, Auto, Search between horizontal
line markers, Search in the zooming area
|
| Analysis |
- Spectral width (threshold, envelope, RMS,Peak RMS, notch)
- WDM (OSNR) analysis
- EDFA-NF analysis
- Filter peak/bottom analysis
- WDM filter peak/bottom analysis
- DFB-LD/ FP-LD/ LED analysis
- SMSR analysis
- Power analysis
- PMD analysis
- Pass/Fail judgment with template
- Auto analysis
- Analysis between horizontal line
|
| Other |
- Optical alignment function with built-in
light source
- Wavelength calibration function
|
|
| |
| |
|
|
- Related Products
- Product Categories
- Complementary Products
- Digital transmission test instruments 10 Gbit/s BERT module, E/O modules, O/E modules
- Optical sources LD light sources, Fabry-Perot LD modules, DFB-LD module, Tunable laser source module, White light source
- Optical power meters Optical powermeters, Sensor modules, Sensor heads, High resolution reflect meter for return loss measurement
- OTDR
- Optical time domain reflectometers
- Optical spectrum analysis products
- Optical spectrum analyzers
- Display tester Display tester for luminance, contrast, flicker and chromaticity measurements.
- Optical attenuators, switches and others Optical attenuators, Optical attenuator modules, Optical switch
- Platforms Multi-application Test system
- Optical sensing products FBG sensor monitor, Optical fiber strain analyzer
- AQ6319
Optical Spectrum Analyzer With an unprecedented wavelength accuracy of ±10 pm (1520-1580 nm), the AQ6319 OSA has become an outstanding instrument in both general and specialized R&D labs for high accuracy wavelength measurement.
- AQ4305
White Light Source
The AQ4305 white light source provides incoherent light to measure wavelength dependent loss characteristics for optical devices and optical fibers, in conjunction with an optical spectrum analyzer.
- AQ2200
Tunable Laser/DFB-LD Sources
The AQ2200 multi application test system is the ideal system for measuring and evaluating a wide range of optical devices and optical transmitters.
|
| |
| |
|
|
|
| |
| |
Specifications |
|
|