Spacer Home Contact_us ob Opportunities ISO_Registration Privacy_Statement
 

 

Standard Software

WE7000 Control Software

  1. Ready to run control software
  2. Saving acquisition data
  3. Bus trigger, arning and External clock
  4. Assorted module binding
  5. Saving the current condition file

 

Optional Software

Add-On Software for "WE7000 Control Software"

 

707702 Computation Function Setup

The Computation Function setup Software is a software program that plugs into the WE7000 control software (version 3.2.0 or later) to provide data computation functions, and allows you to freely define primary processes—such as basic arithmetical operations, absolute values, square root extraction, pulse width processing, digital filtering, differential/integration computation, and FFT—for the measured data to obtain desired computation results. The Mathematical Computation Software also supports waveform parameter computations for a digitizer module.

 

Software
707703 Remote Monitor Add-on Software

This software program provides a function that allows multiple PCs existing on the network connected via Ethernet or optical fiber cable to access the same measuring station. The measurement conditions of the measuring station can be monitored by multiple PCs. Sharing a single measuring station among several people (multiple PCs) enables efficient use of the instrument such as in a learning environment

 

Application Program Development

707741 WE
Control API
On an Windows base hardware (OS : Windows 95, 98SE, NT, 2000, XP), it is available to develop an own measurement system by using of WE Control API. WE Control API is a command group to control the WE7000 from Application Program like a VB, VC++, Matlab/Simulink and LabVIEW. They are DLL files and OCX files to get event. Yokogawa has integrator group. Please request us if you would like to develop your own control panel with WE7000.

 

 

Other Software

 

Caption_Header

Yokogawa

Model WE7000
PC-Based Measurement Instruments

 
previous URL Next URL
< Links >
 
 
 
 
WE7000
 
 
  Characteristics:  
 
  • Simple data acquisition without any software development
    Each WE7000 system includes the standard control software and each module has its firmware resident within the module.
  • Isolation and noise immunity
    Isolation and noise immunity are very important for the mechanical electronics area. The WE7000 has great isolation from the base station to the input modules as well as channel to channel (depending on the module) isolation.
  • Various precision modules with traceability
    WE7000 has various modules from 2 Hz to 1 GS/sec digitizing rates. There are also modules with signal output capability, including a precision D/A and a function generator.
  • Remote control and monitoring using Ethernet Communication
    WE7000 control, monitoring, and real time saving of data are all available using Ethernet communication.
 
 
  Product Description:  
 
 

The WE7000 PC based system is designed to address the need for a fast, reliable data acquisition system. The modular design provides greater flexibility and is easily expandable. The Windows based software provides an intuitive virtual front panel for easy setup and control.

 
 
 
  Digitizer modules :  
space
The channel number can be expanded to eight times the number listed below by connecting several modules together (when using the 8 slot measuring station). Click the model name to view the specifications in detail (PDF file).
Model Max. Sampling Rate Frequency Range Res. No. of Chan. Range Max. Memory (words) Specs
WE7311
1 GS/s
DC to 400 MHz
8 bits
1
5 mV/div to 500 mV/div (1-2-5 steps)
2 M
WE7111
100 MS/s
DC to 40 MHz
8 bits
1
5 mV/div to 5 V/div (1-2-5 steps)
100 k
WE7116
20 MS/s
DC to 8MHz
12 bits
2
±100 mV to 50 V (1-2-5 steps)
4 M
WE7275
1 MS/s
DC to 400 kHz
14 bits
2
±100 mV to 200 V (1-2-5 steps), 350 V
4 M
WE7273
New!
100 kS/s
During DC coupling: DC to 40 kHZ
During AC coupling: 0.1 Kz to 40 kHz
16 bits
8
±50 mV to ±50 V (in 1-2-5 steps)
8 M
WE7271/
WE7272
100 kS/s
DC to 40 kHz
16 bits
4
±1 V to 20 V (1-2-5 steps), 35 V
4 M
WE7251
100 Ks/s
DC to 10 kHz
16 bits
10
±1 V to 20 V (1-2-5 steps)
1 M
 
 
  Signal Conditioner Digitizers:  
space
The channel number can be expanded to eight times the number listed below by connecting several modules together (when using the 8 slot measuring station). Click the model name to view the specifications in detail (PDF file).
Model Input Signals Max. Measurement Interval Res. No. of Chan. Max. Memory (words) Spec
WE7235
Acceleration and voltage measurement
DC to 40 kHz
16 bits
4
4 M
WE7241
Thermocouple (12 types),
DC voltage (Max. 50 Vrange)
0.5 s (0.2 s possible with 2 ch) to 60 s
14 bits (When DC is input)
10
-
WE7245
Strain (Isolated differential input),
Voltage (Max. 20 Vrange)
10 μs
14 bits (When DC is input)
4
2 M
space
  Signal Sources:  
 
The channel number can be expanded to eight times the number listed below by connecting several modules together (when using the 8 slot measuring station). Click the model name to view the specifications in detail (PDF file).
Model Output Waveform Oscillation Frequency Range D/A Resolution No. of Chan. Output Range Spec
WE7121
sine wave/square wave/triangle wave/ramp wave/pulse wave/arbitrary wave
sine wave: 1 μHz to 10 MHz,
other waveforms: 1 μHz to 200 kHz
12 bits (Characters included)
1
±10 V (setting resolution: 1 mV)
WE7281/
WE7282
sine wave/pulse wave/ramp wave/triangle wave/arbitrary wave/DC
sine wave: 1 mHz to 20 kHz
other waveforms: 1 MHz to 10 kHz
16 bits (Characters included)
4
±10 V (1-2-5 steps)
space
  CAN Bus Signal Input/Output:  
 
Click the model name to view the specifications in detail (PDF file).
Model Function Baud rate Spec
WE7081
New!
CAN Data Acquisition, CAN Data Output, Module Linking 10 kHz to 1 MHz Hi-Speed CAN (ISO11898)
 
  Digital I/O:  
 
Click the model name to view the specifications in detail (PDF file).
Model Function Input/Output Dots Other Spec
WE7262
Digital signal input/output (with a counter)
32
Measurement interval when measuring input pattern continuously: 10 ms to 10 s, Channel number of counter: 2
 
  Counter:  
 
Click the model name to view the specifications in detail (PDF file).
Model Function No. of Channels Input Sensitivity Min. Input Pulse Width Spec
WE7141
frequency/interval/time interval/pulse width/duty ratio/fre uency ratio/addition calculation
2
50 mVrms: DC < input frequency< 60 MHz
100 mVrms: 60 MHz < input frequency< 120 MHz
10 ns
WE7521
Period, time interval totalize count, quadrature encoder, frequency ratio
4
When hysteresis width in NORMAL and frequency is 1 MHz or less: 1.0 Vpp (typical value)
When hysteresis width is WIDE and frequency is 1 MHz or less: 3.0 Vpp (typical value)
50 ns
 
  Downloads:  
 
  pdf_pic Downloads:General Specifications  
base
 
 
Scroll down
 
scroll
 
  scroll up  
 
index