Full Set of communications to support Data Acquisition

Datum-Y supports standard protocols such as HTTP, FTP, SMTP and SNTP based on Ethernet connection (10BASE-T, 100BASE-TX), so no dedicated software is necessary. You can also use the user authentication function to permit access only to pre-registered users, in order to prevent illegal access to Datum-Y from networks. Up to seven users (one administrator and six users) can be pre-registered.

 

Web Server Function

You can monitor and operate Datum-Y’s screens and functions via a web browser. The monitor screen can be updated automatically (every 5, 10 or 30 seconds) or manually. Select the monitor page where Datum-Y screens can be monitored, or the operator page where both monitoring and operation are possible. User authentication can be set for each page to prevent illegal access.

 

FTP Server Function

You can output a list of files stored in Datum-Y’s internal memory or connected external storage media, and transfer, delete or otherwise manipulate desired files.

 

FTP Client Function

You can transfer the measurement data files/alarm data files created in Datum-Y’s internal memory or connected external storage media, to a FTP server.
Two file transfer destinations can be set (primary and secondary). If the primary FTP server goes down, files will be transferred to the secondary FTP server

 

E-mail Delivery Function

You can send e-mail to notify occurrence/reset of alarms, power recovery after outage, errors in external storage media, FTP client errors, and scheduled times. Up to two groups can be set, each containing a different set of recipients.

 

RS485, RS232

Built-in Modbus Protocol Capability

Serial communication (RS-232, RS-485) can be performed using a dedicated protocol as well as Modbus RTU and Modbus ASCII protocols that are supported by Datum-Y’s standard capability. Datum-Y can be connected to other equipment to acquire data simultaneously with temperature / voltage. 32 dedicated communication channels are provided.

 

USB

Datum-Y connects with a PC. You can acquire data, change Datum-Y settings or perform various other operations on Datum-Y from a PC.

 

Printer

RS-232 (Printer) You can connect a printer via RS-232 connection to print paper reports on site.

Caption_Header

Yokogawa

Datum-Y, XL100 Series,
Portable Data Station (Data Logger)

 
previous URL Next URL
< Links >
 
 
 
Yokogawa Datum-Y , XL100 serires Data Station - Data Logger

Characteristics:

  • World first in measuring instruments! Obtained IPv6 Ready Logo Phase-1
    (ID:01-000273)
  • Portable size (155×155×55mm) and lightweight (approx. 800g) lets you carry with one hand.
  • Wide viewing angle TFT-LCD
  • Best noise resistance performance in the category of handheld instruments.
  • Improves resistance to impact by use of rubber boots (standard accessory).
  • Web server, FTP server/client and e-mail distribution function are equipped as standard
  • Auto set & Auto run function by inserting external memory.
  • Alarm, Statistical operation and external function
 
  Applications:  
 
 
  • Variety of simple temperature tests and evaluations (thermostatic chambers, electricfurnaces, inverter control units, etc.)
  • Acquisition of facility maintenance data (data on the same time scale such as temperature, voltage, pulse, etc.)
  • Remote monitoring of analog data utilizing intranet LAN
  • Acquisition of electric power and temperature data on the same time scale during energy-saving operation
 
 
  Product Description:  
 

space

The Yokogawa Datum-Y portable data logger directly measures and acquires temperature (thermocouple/resistance temperature detector) and DC voltage. It provides two configurations of input terminals offering 8 and 16 channels, repectively individual channels can be set independently through universal insulated inputs. The Datum-Y is designed to achieve high performance and easy operation on site. Datum-Y provides wide ranging funtions and various communication capabilities to support diverse data acquisition applications.
 
 
  Features:  
 
 
  • All Channels Adopt Universal Insulated Inputs
    The channels in the analog input part adopt insulated inputs, which means that temperature (thermocouple/resistance temperature detector) and voltage can be set differently for each channel. The digital inputs are equipped with one pulse channel and two logic channels.
  • Best-In-Class Noise Resistance
    Datum-Y achieves excellent noise resistance rated among the best in the class of handy measuring products. With Datum-Y, stable measurement is possible in various noise environments, such as when measuring inverter-driven machines or thyrister-controlled units that are commonly used for energy-saving purposes.
  • Data Saving at 100ms
    Datum-Y saves data at the maximum speed of 100 ms (when the 8-channel terminal block is used).
    You can save data in either binary format or ASCII format (for display in Excel*). Binary data can be checked on site in the review mode or shown in waveforms using the supplied “D-TOOL” software.
  • Acquisition of Large Amounts of Data
    Using External Storage Media
    Acquisition of Large Amounts of Data Using External Storage Media Datum-Y lets you save data not only in its internal memory (16 MB), but also in external storage media such as compact flash memory cards* and SD cards* (up to 512 MB). Data saved in these media can be copied to a USB memory* for easy transfer to a PC.
 
 
  Special Functions:  
 
 
  • Spot Chech of Acquired Data
    You can check measured data (binary) on Datum-Y right away. Overall trend and alarm output can be checked on the spot immediately after acquisition.
  • While Datum-Y is logging data, you can display past data and current data in the logging review mode for comparison and identification of trend.
    (This function is available only when binary data is acquired.)
  • Calculation Function
    Datum-Y is capable of inter-channel calculations (among channels, between channels and constants, etc.), statistical operations (minimum, maximum, average, root-mean-square and peak values from start to end of logging), and scaling.
  • Trigger Function
    Datum-Y acquires data before and after a trigger (pre-trigger/trigger delay) to help you detect and analyze the cause of an error. You can select the single mode (a trigger is issued only once) or continuous mode (a trigger is issued every time the condition is satisfied).
  • Alarm Function
    Datum-Y can be fitted with up to four alarm output channels. One alarm can be set for each input channel, and multiple channels can be combined freely with AND/OR gates. You can also use the e-mail delivery function to notify specified e-mail addresses upon occurrence or reset of an alarm
  • Auto Set and Run Function
    Simply connect an external storage medium (CF card, SD card or USB memory) containing a predefined file (AUTORUN.SET), and Datum-Y will change the necessary settings and take measurements automatically. (You need to enable the automatic measurement function of Datum-Y beforehand.)
 
 
  Specifications:  
 
 
ANALOG INPUT  
Input method
Floating unbalanced input, insulated between channels (Terminal "b" is shared by resistance temperature detector inputs.)
Number of inputs
8 channels (XL101), 16 channels (XL102, XL104)
Terminal shape
Push-lock screw (XL101, XL102), M3 screw (XL104)
Measurement
interval
100 ms (only when the 8-channel terminal block is used), 200 ms, 500 ms, 1 sec, 2 sec, 5 sec, 10 sec, 20 sec, 30 sec, 1 min, 2 min, 5 min, 10 min, 20 min, 30 min, 1 hr
Input type
TC (thermocouple), RTD (resistance temperature detector), DCV (direct-current voltage)
* RTD for XL101 and XL102 only
Range and measurement range Reference operating conditions:
Temperature (23±2°C), humidity (55±10%RH), power supply voltage (100 to 240 VAC), power supply frequency (50/60 Hz±1% or less), warm-up (30 minutes or longer), without vibration, etc. that do not affect the operation of the instrument
Input Range Measurement Accuracy Res.
DCV 100mV -100.00 to 100.00mV ±0.1% of f.s. 10μV
500mV -500.0 to 500.0mV 100μV
1V -1.0000 to 1.0000V 100μV
5V -5.000 to 5.000V 1mV
10V -10.000 to 10.000V 1mV
30V -30.00 to 30.00V 10mV
1-5V/f.s. 1.000 to 5.000V 1mV
TC R *1 0 to 1768°C ±0.05% of f.s.±2°C *5 1°C
S *1 0 to 1768°C
B *1 600 to 1800°C
K *1 -200.0 to 1372.0°C ±0.05% of f.s.±1°C *5 0.1°C
E *1 -200.0 to 1000.0°C
J *1 -200.0 to 1200.0°C
T *1 -200.0 to 400.0°C
N *1 -200.0 to 1300.0°C
W *2 0 to 2315°C ±0.05% of f.s.±2°C *5 1°C
L *3 -200.0 to 900.0°C ±0.05% of f.s.±1°C *5 0.1°C
U *3 -200.0 to 400.0°C
RTD Pt100 *4 -200.0 to 850.0°C ±0.05% of f.s.±0.5°C *5 0.1°C
JPt100 *4 -200.0 to 500.0°C
*1 R,S,B,K,E,J,T,N : IEC584-1 (1995), DIN IEC584, JIS C 1602-1995
*2 W : W-5% Rd/W-26% Rd (Hoskins Mfg. Co.), ASTM E988
*3 L : Fe-CuNi, DIN43710, U : Cu-CuNi, DIN43710
*4 Pt100 : JIS C 1604-1997, IEC 751-1995, DIN IEC751-1996
JPt100 : JIS C 1604-1989, JIS C 1606-1989
*5 "f.s." for TC and RTD means the full scale of the measuring range.
DIGITAL INPUT  
Number of inputs
Pulse input: 1 channel, Logic input: 2 channels
Input Specification
Lo: Below 0.9 V or terminal short-circuited, Hi: 2.1 V or higher or terminal open
Maximum Input 10 VDC
Input Range Measurement Max. Res.
Pulse
(Instant value)
None 50k/Measurement interval
0 to 50000c
1c
Pulse
(Integral Value)
50kc/f.s. 50k/Measurement interval 1c
500kc/f.s. 10c
5Mc/f.s. 100c
50Mc/f.s. 1kc
500Mc/f.s. 10kc
Pulse
(# of rev.)
500rpm/f.s. 50k/sec
(The number of pulses per second is counted and converted to the number of revolution)
-
5krpm/f.s. -
50krpm/f.s. -
500krpm/f.s. -
Logic (DI) - - -
 
CALCULATIONS  
Inter-channel
calculation
Inter-channel calculation is possible.
(Measurement / calculation data / communication data, constant)
Linear scaling Ianges capable of scaling: DCV, TC, RTD, pulse
Available range of scaling: -30000 to 30000
Decimal point position: Selectable from 0.0000, 00.000, 000.00, 0000.0 and 00000
Unit: Can be set by the user (6 characters) or from standard list
Statistical operation Maximum value (MAX), minimum value (MIN), average value (AVE), peak value (P-P) and root-mean-square value (RMS) between the start and stop of logging
STORAGE  
Internal memory: 16 MB
External storage medium: Compact flash memory card (Type II), SD card, USB memory (Only the copy function is supported by USB memory. Only those USB memories that have been verified by YOKOGAWA are recommended.)
Storage data type  
Type Description Format
Logging data Measurement is performed at specified intervals in logging mode. / Instantaneous values (calculation data) are saved. Binary or ASCII
Manual sampling data Measurement is performed for all channels in free running mode when a certain key is operated. / Calculation data (instantaneous values) is saved. ASCII
Alarm data The same contents as the alarm summary are saved in logging mode each time an alarm occurs. ASCII
Screen image data The image data of the currently displayed screen is saved when a certain key is operated. BMP
Setting data The settings made to the instrument are saved when a certain key is operated. Binary
Log data The same contents as the log display are saved when a certain key is operated. ASCII
Backup file When data is not saved properly to the internal memory, CF or SD card in logging mode (since, for instance, no card has been inserted or the card is full), the data is saved to the backup memory. Same format as logging data
ALARM FUNCTIONS
Alarm type Hi (high limit), Lo (low limit), window-in (within specified upper/lower range), window-out (outside specified upper/lower range) (Only Hi and Lo are available for logic inputs.)
Alarm delay time Number of measurements: 0 to 36,000
Display Alarm status is displayed in the status display area and measured values are displayed in red when an alarm occurs. (Selectable from non-hold and hold-type)
Hysteresis ON/OFF switchable (0.5% of span fixed, common to all channels) 4 channels (not insulated)
Buzzer ON/OFF switchable when being output
Recording Up to 120 sets of latest information can be recorded.
Output format Open collector, 5 V pull-up resistor (100 kΩ)
Contact capacity 5 to 40 V, 100 mA
TRIGGER FUNCTIONS
Type Input to the external trigger input terminal, level (high limit, low limit, window-in, window-out), alarm occurrence, time, timer (timer can only be used to stop logging) For level, the trigger target channels must be specified.
Mode Single trigger (ends when the stop trigger is caused) Continuous trigger (creates a file each time the trigger is caused)
Pre-trigger The data before the trigger is saved.
Trigger delay Data is saved when sampling has been performed the specified number of times following the trigger.
POWER SUPPLY
AC POWER SUPPLY
Supply voltage 100 to 240 VAC
Operating voltage 90 to 132, 180 to 264 VAC
Frequency 50/60 Hz
BATTERY
Battery used Dedicated lithium ion battery (2,400 mAh, 7.4 V)
Operation The battery can be charged on the main unit only. The instrument runs on the AC adapter when both battery and AC adapter are used.
Charging function The battery can be charged while the instrument is in use. Charging takes approximately 8 hours.
Continuously operable time Approx. 7 hours
(When used at 25°C, with measurement interval of 5 minutes or longer, backlight auto-off set to 5 minutes or less, and no communication)
GENERAL SPECIFICATIONS
Location for use:
Indoor, at an altitude of 2000 meters or less
Operating Temp.
0 to 50°C (0 to 40°C if a battery is used),
Humidity range: 5 to 85%RH (no condensation)
Storage Temp.
-20 to 60°C
Storage Humidity
90%RH or less (no condensation)
INSULATION RESISTANCE
Terminals / Frame 20 MΩ or higher (500 VDC)
Between input terminals** 20 MΩ or higher (100 VDC)
Terminal and Digital I/O 20 MΩ or higher (100 VDC)
WITHSTAND VOLTAGE
Terminals / Frame 350 Vp-p (50/60 Hz), 1 min.
Between input terminals**
350 Vp-p (50/60 Hz), 1 min.
Terminal and Digital I/O 350 Vp-p (50/60 Hz), 1 min.
   
Size Approx. 155 (W) x 155 (H) x 55 (D) mm
(Without projecting parts and rubber boot)
Weight Approx. 800 g (Without battery and rubber boot)
SAFETY STANDARD
Safety Ratings
EN61010-1
Measurement category I (circuit voltage used: ±60 VDC) Pollution degree 2
Rated transient overvoltage 350 Vp-p
EMISSION STANDARD
Complying standard: EN61326 Class A, EN55011 Class A Group 1
EN61000-3-2, EN61000-3-3

This product class A for use in an industrial environment and may cause radio interference if used for domestic use. Therefore, appropriate measures must be taken when using it for domestic use.

 