- ***3 warranty***
- High accuracy 0.04% at DC voltage and 50,000 count / 51-segments bar graph display
- Memory function saves 50 data in manual-mode memory & 600 data in logging-mode memory
- IR communication function
- Internal memory function to store measured data
- User calibration function
- Shockproof elastomer casing
- Safety shutters prevent erroneous insertion of test leads into current measurement terminals (so called "Terminal Shutters")
- CAT III, 600V
|
|
 |
| |
|
|
 |
|
| |
|
These multimeters are rugged, extremely reliable, and highly accurate, ideal for applications that require high precision measuring, 73401 can be used for many types of situation such as electrical work, maintenance and R&D. IR communication allows easy management of measured data. They have basic dc voltage accuracy of 0.02 or 0.04% c/w a 51 segment bargraph, a continuity buzzer, a diode check and an auto-power off feature. |
|
| |
| |
|
|
 |
|
| |
| DCV |
: |
0.04% + 2, |
50.000 mV to 1000.0 V |
| ACV |
: |
0.7% + 30, |
500.00 mV to 1000.0 V |
| DCV + ACV |
: |
1.0% + 10, |
5.000 V to 1000 V |
| ACA |
: |
1.0% + 20, |
500.00 μA to 10.000 A |
| DCA |
: |
0.2% + 2, |
500.00 μA to 10.000 A |
| DCA + ACA |
: |
1.5% + 10, |
500.0 μA to 10.00 A |
| Resistance |
: |
0.1% + 2, |
500.00 Ω to 50.000 MΩ |
| Continuity Check |
: |
Sounds at 100 ± 50 Ω or less, 500.0 Ω |
| Diode Test |
: |
1.0% + 2, |
2.4000 V |
| Temp. |
: |
1.0% + 1.5 deg.C,
[1.0% + 2.0 deg.F, |
-50.0 to 800.0 deg.C
-58.0 to 1472 deg.F] |
| Capacitance |
: |
1.0% + 5, |
5.000 nF to 50.00 mF |
| Frequency |
: |
0.02% + 1, |
2.000 Hz to 99.99 kHz |
| Duty Cycle |
: |
±1%, |
10 to 90% |
|
| |
| |
|
|
 |
|
| |
| Additional Functions |
: |
RS-232-C, data memory, max/min value memory, relative/% value computation, logarithm computation, data/autohold, overvoltage warning |
| Display |
: |
50,000-count digital reading and 51-segments bar graph |
| Measuring Rate |
: |
3 times/sec for display, 10 times/sec for bar graph |
| Operating Temp. & Humidity |
: |
-10 to 50 deg.C; 80% RH or less at -10 to 40 deg.C, or 70% RH or less at 40 to 50 deg.C |
| Storage Temp. & Humidity |
: |
-25 to 60 deg.C, 70% RH or less |
| Temp. Coefficient |
: |
Add the accuracy × 0.05/deg.C to the basic accuracy at a temperature within -10 to 18 deg.C and 28 to 50 deg.C |
| Withstanding Vol. |
: |
5.55 KV, AC for 1 minute |
| Power Supply |
: |
Two AA (R6) dry cells |
| Battery Life |
: |
Approx. 120 hours |
| Auto Power Off |
: |
Approx. 20 minutes after |
| Dimensions |
: |
85(W) x 191(H) x 40 (D) mm |
| Weight |
: |
Approx. 450g |
| St'd Accessories |
: |
Instruction manual: 1, Test leads: 1, AA batteries:2 |
|
| |
| |
|
|
|
|
| |
| |
 |
|
|