- Accuracy 0.2% at DC voltage and 4000 count / 40-segments bar graph Display
- Selectable RMS & mean value for AC measurement
- User calibration function
- Shockproof elastomer casing
- Safety shutters prevent erroneous insertion of test leads into current Measurement terminals (so called "Terminal Shutters")
- CAT III, 600V
|
|
 |
| |
|
|
 |
|
| |
|
Accuracy 0.2% at DC voltage and 4000 count / 40-segments bar graph display. AC voltage measurement method is selectable between RMS value and mean value measurement. Main body is covered by elastomer material that provides better impact resistance. Terminal shutters prevent erroneous insertion of test leads into current measurement terminals to avoid wrong use.
The 733 series are rugged, extremely reliable, and highly accurate. These DMM's are ideal for applications that require precision measuring. |
|
| |
| |
|
|
 |
|
| |
| DCV |
: |
0.2% + 1, |
400.0 mV to 1000 V |
| ACV |
: |
0.5% + 5, |
400.0 mV to 1000 V |
| DCA |
: |
0.5% + 2, |
400.0 μA to 10.00A |
| ACA |
: |
0.75% + 5, |
400.0 μA to 10.00A |
| Resistance |
: |
0.4% + 1, |
400.0 Ω to 40.00 MΩ |
| Continuity Check |
: |
Sounds at ± 20 Ω or less, 400 Ω |
| Diode Test |
: |
1.0% + 2, |
2.000V |
| Temp. |
: |
±1.0 deg.C at 0 to 70 deg.C,
[±1.8 deg.F at 32 to 158 deg.F, |
-50.0 to 150.0 deg.C
-58.0 to 302.0 deg.F] |
| Capacitor Check |
: |
2.0% + 5, |
10.00 nF to 1000 μF |
| Frequency |
: |
0.02% + 1, |
10.00 Hz to 99.99 kHz |
|
| |
| |
|
|
 |
|
| |
| Additional Functions |
: |
Relative and % value computation, data/auto hold, overvoltage warning |
| Display |
: |
4000-count digital reading and 40-segments bar graph |
| Measuring Rate |
: |
2.3 times/sec for display, 23 times/sec for bar graph |
| Operating Temp. & Humidity |
: |
-10 to 50 deg.C; 80% RH or less at -10 to 40 deg.C, or 70% RH or less at 40 to 50 deg.C |
| Storage Temp. & Humidity |
: |
-20 to 60 deg.C, 70% RH or less |
| Temp. Coefficient |
: |
Add the accuracy × 0.1/deg.C to the basic accuracy at a temperature within -10 deg.C to 18 deg.C and 28 to 50 deg.C |
| Withstanding Vol. |
: |
5.55 KV, AC for 1 minute |
| Power Supply |
: |
Two AA (R6) dry cells |
| Battery Life |
: |
Approx.?350 hours |
| Auto Power Off |
: |
Approx. 20 minutes after |
| Dimensions |
: |
85(W) x 191(H) x 40 (D) mm |
| Weight |
: |
Approx. 450g |
| St'd Accessories |
: |