Parameter |
Specification |
| Method of detection |
Mean value |
| Display |
LCD(Digital display:1999 counts) |
| Response Time |
Approx. 1 seconds |
| Range Switching |
Manual-range |
| Data Hold |
On all range |
| Peak Hold |
On all range |
Ambient temperature
and humidity |
-10 to 50 deg.C, 80% RH or less (no condensation)) |
| Temperature Coefficient |
- |
Influence of external
magnetic field |
15mA or less in proximity to a 10mm-dia conductor carrying 100A |
| Influence of conductor position |
2% or less |
| Influence of residual current |
10mA or less in proximity to a 10mm-dia conductor carrying 100A |
| Safety Standard |
Conforms EN 61010-1, EN61010-2-032 |
| Circuit Voltage |
600Vrms or less |
| Withstanding Voltage |
3.7kV AC for one minute |
| Power Supply |
6F22(006P)9V x1 or 6LR61 x1 |
| Battery Life |
Approx. 60 hours (continuous) |
| Consumed Current |
Approx. 5mA |
Diameter of measurable
conductor |
68mm at maximum |
| Dimensions |
Approx. 129(W) x 248(H) x 55(D)mm |
| Weight |
Approx. 570g |
| Accessories |
User's manual(IM CL360), batteries, carrying case(93031) |