Spacer Home Contact_us ob Opportunities ISO_Registration Privacy_Statement
 
space
Yokogawa
Model CL340, Leakage Current Tester,
True RMS Clamp-on Meters
 
previous URL Next URL
< Links >
 
 
green_line
 
 

     Product Information:

  • ***Lifetime warranty***
  • 3 3/4 digit LCD display
  • Mean value display
  • Leakage current measurement with current range from 40mA to 400A
  • Manual range switching and auto power-off functions
  • 40mm in diameter of measurable conductor
  • Mean value display
  • Auto power-off
  • Manual range switching
  • Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)
 
space
  Product Description:  
space
green_line
 

 

 

 

Model CL340 Clamp-on tester provides an easy-to read, 3999 count display. It measures current from 40 mA to 400 AAC.  It is an inexpensive, accurate and robust dedicated leakage meter with a mid-size clamp diameter  that accepts conductors up to 44 mm diameter.

CL300 series and 30031 have basic function of leakage current measurement. These clamps allow you to measure current range from 3mA to 1000A. Choose your desired diameter of measurable conductor from 24mm to 68mm.

 
 
  Product Accuracy:  
space
green_line
 
Parameter
Reference
Accuracy
WIDE(20Hz to)
50/60Hz
AC Current 40mA/400mA 2.5+10 (20 to 1kHz) 1.0+5 (50/60Hz)
400A(0 to 350A) 2.5+10 (40 to 1kHz) 1.0+5 (50/60Hz)
400A(350 to 400A) 5.0 (40 to 1kHz) 2.0 (50/60Hz)
 
  Product Specifications:  
space
green_line
 
Parameter
Specification
Method of detection Mean value
Display LCD(Digital display:3999 counts)
Response Time Approx. 2 seconds
Range Switching Manual-range
Data Hold On all range
Peak Hold On all range
Ambient temperature
and humidity
0 to 40 deg.C, 85% RH or less (no condensation)
Temperature Coefficient
-
Influence of external
magnetic field
10mA or less in proximity to a 15mm-dia conductor carrying 100A
Influence of conductor
position
40/400mA range:Within 5dgt at every part inside the jaw400A range
0 to 250A:Within ±0.5%rdg ±5dgt at every part inside the jaw section
Influence of residual current 12mA or less in proximity to a 10mm-dia conductor carrying 100A
Safety Standard Conforms EN 61010-1, EN61010-2-032
Circuit Voltage 300Vrms or less
Withstanding Voltage 3.7kV AC for one minute
Power Supply R0-3(UM-4) x 2 or LR03 x 2
Battery Life Approx. 40 hours (continuous)
Consumed Current Approx. 13mA
Auto power-off Approx. 10 minutes
Diameter of measurable conductor 40mm at maximum
Dimensions Approx. 81(W) x 185(H) x 40(D)mm
Weight Approx. 270g
Accessories User's manual(IM CL340), batteries, carrying case(93030)
 
  Downloads:  
space
green_line
 
  pdf_pic Downloads: General Specifications  
base
 
space
Scroll down
 
scroll
 
  scroll up  
 
web index