Spacer Home Contact_us ob Opportunities ISO_Registration Privacy_Statement
 
space
Yokogawa
Model CL150, AC Current, AC Voltage
Mean Value Clamp-on Meters
 
previous URL Next URL
< Links >
 
 
green_line
 
 

     Product Information:

  • ***Lifetime warranty***
  • 3 3/4 digit LCD display
  • AC current measurement with current ranges up to 2000A
  • Mean value display
  • AC/DC voltage and resistance measurements
  • DC output
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for comformity to safety standards:
    EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)
 
space
 
cart   Order YOKOGAWA TMI Products on-line
 
 
  Product Description:  
space
green_line
 

 

 

 

The CL150 is a verstatile and highly accurate Clamp-on meter with a array of features ideal for most applications. This unit is rugged, reliable and cost effective.

CL100 series and 2343 series have basic function of AC current measurement. These clamps allow you to measure current range from 20mA to 1000A. Choose your desired diameter of measurable conductor from 24mm to 54mm.

 
 
  Product Accuracy:  
space
green_line
 
Parameter
Reference
Accuracy
AC Current 400A 1.0+3 (50/60Hz)
2.0+3 (40 to 1kHz)
2000A(0 to 1500A) 1.0+3 (50/60Hz)
3.0+3 (40 to 1kHz)
2000A(1500 to 2000A) 3.0(50/60Hz)
AC Voltage 40/400/750V 1.0+2 (50/60Hz)
1.5+3 (40 to 1kHz)
DC Voltage 40/400/1000V 1.0+2
Resistance 400/4k/40k/400kΩ 1.5+2 , Beeps at below 50±35Ω(cntinuity chek)
DC Output 400A(0 to 400mV) ±1.5% rdg ±0.5mV (50/60Hz)
±2.5% rdg ±0.5mV (40 to 1kHz)
2000A(0 to 150mV/0 to 1500A) ±1.5% rdg ±0.5mV (50/60Hz)
±3.5% rdg ±0.5mV (40 to 1kHz)
2000A(150 to 200mV/1500 to 2000A) ±3.5% rdg (50/60Hz)
 
  Product Specifications:  
space
green_line
 
Parameter
Specification
Method of detection
Mean value
Display
LCD(Digital display:3999 counts)
Response Time
Approx. 2 seconds
Range Switching
Manual-range(on AC current range)/
Auto-range(on AC/DC voltage range, resistance range)
Data Hold
On all range
Peak Hold
On AC current range
Ambient temperature and humidity
0 to 40 deg.C, 85% RH or less (no condensation)
Temperature Coefficient
-
Influence of external magnetic field
1A or less at 400A/m
Influence of conductor position
±(2.0% rdg + 3dgt) or less
Safety Standard
Conforms EN61010-1, EN61010-2-031, EN61010-2-032
Circuit Voltage
1000Vrms or less
Withstanding Voltage
5.55kV AC for one minute
Power Supply
R6P(SUM-3) x2 or LR6 x2
Battery Life
Approx. 150 hours (continuous)
Consumed Current
Approx. 5mA
Sleep Function
Automatically powered down in about 10 minutes after the last switch operation
Diameter of measurable conductor
54mm at maximum
Dimensions
Approx. 105(W) x 247(H) x 49(D)mm
Weight
Approx. 470g
Accessories
User's manual(IM CL150), batteries,
carrying case(93034)
 
  Downloads:  
space
green_line
 
  pdf_pic Downloads: General Specifications  
base
 
space
Scroll down
 
scroll
 
  scroll up  
 
web index