- Sharp and large 5-digits LED display with 20 mm high digits
- 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire & 3-phase 4-wire models are available.
- Wide variety of measurement items Integrated power, optional integrated power, instantaneous power, voltage (instantaneous, maximum & minimum values), current (instantaneous & maximum values) and power factor (optional feature) are available.
- Wide display range, unit of W, kW & MW by LED indicator
- Fully supported communication function
RS485 communication (MODBUS and PC-link protocols are supported) and LON communication can be optionally selected.
- Easy to set and maintain CT-ratio, PT-ratio, integrated low-cut power, etc. by front-panel key switch.
|
|
|
| |
| |
|
|
|
| |
|
|
The UZ005 Power Monitor (for 1/4 DIN size panel mounting type) can help energy saving, thus reducing cost, and also help diagnose electrical equipment. It measures electric energy (power) consumed by electrical equipment and displays the value as the integral power consumption. It also displays instantaneous power, voltage, current, power factor, etc. For optional output function, 4 to 20 mA analog output for instantaneous power value or integrated pulse output is available. For optional communication function, RS485 or LON communication interface is available.
|
|
|
| |
| |
|
|
 |
|
| |
|
| Display |
| Display: |
7-segment LED as its display. |
| Digit height: |
0.56” high digits |
| Color: |
Red |
| Range: |
-99999 to +99999 |
| Number of Digits: |
5 digits |
| Measuring Function: |
Accuracy: |
| Instantanous power, voltage r.m.s. value,
current r.m.s. value: |
±0.5% of rated value (at
23°C±2°C) |
| Integrated power energy: |
±0.5% of rated value (at
23°C±2°C) |
| Active power : |
±2% of rated value (at 23°C±2°C) |
| Analog Output : |
±0.5% of span (at 23°C±2°C) |
| |
| Insulation resistance: |
100 MΩ minimum (at 500 V DC) |
| Withstand voltage: |
2000 V
AC for 1 minute |
| output -1000 V AC for 1 minute |
| output -500 V AC for 1 minute, between optional integrated
control signal and (input, output, communication
output, power supply and ground) |
| Impulse withstand voltage: |
5kV (1.2/50μs) |
| Analog Output |
| Allowable load resistance
: |
0 to 750Ω |
| Output Signal : |
4 to 20 mA DC |
| Pulse Output: |
|
| No. of outputs: |
1 |
| Output signal: |
Open collector |
| Contact capacity: |
30 V DC, 200 mA |
| Pulse unit: |
Indicates actual kWh corresponding 1
pulse input to this instrument. |
| Communications: |
|
| Serial Bus: |
RS-485 communication |
| LON Communication: |
Measuring data can be simply read out on
personal computer through LON communication
adapter and DDE: server without consciousness
of communication. Also, control of optional
integration and initaialization of maximum and
minimum values can be done through personal
computer. |
| General |
| Safety standards: |
Compliant with IEC/EN61010-1
Under application for UL611010 approvale |
| Power source: |
85 to 264V AC, 45 to 65Hz |
| Power dissipation: |
6VA (at 100V AC)
8VA (at 200V AC) |
| Operating Power |
-10 to 55°C |
| Storage Temp. : |
-20 to 70°C |
| Ambient humidity: |
5 to 90% RH (no condensation) |
| |
| Case: |
Polycarbonate resin (PC), UL94 V-0
Dustproofness and dripproof
IP5X |
| Terminal block: |
Polybutylene terephthalate (PBT), UL94 V-0 |
| Terminal cover: |
Polyamide resin (PA6), UL94 V-2 |
| Dimensions: |
110 x 110 x 128 mm (H x W x D) |
| Weight: |
Approx. 600 g |
|
|
| |
| |
|
|
|
|
| |
| |
General Specifcations |
|
|
|
|
|
 |
|
|
|
|