MLA and MLD Series
Explosion Proof Meters (Loop Powered)
 
previous URL Next URL
< Links >
 
 
green_line
 
 

Yokogawa Y Series, Elapsed Time Meters

 Characteristics:

green_line
 
  • Horizontal or vertical pipe mounting
  • Dust-ignition proof
  • Highly reliable
 
 
  Product Description:  
space
green_line
 

 

The Model MLA and MLD field mounted remote indicators receive DC voltage or current signal inputs from electronic Transmitters and indicate process measurement values. They are available with Analog or Digital displays. Both accept 4-20 mA DC input. The remote indicator MLA also accepts 10-50Ma DC and 1-5 VDC. Mounting options are Horizontal or Vertical Pipe mounting, and wall mounting.
Our standard scale for MLA is black background, white numerals and letters, 50 divisions, 0-100%. For MLD, our standard display is 0-100.0%.

Loop powered indicators are commonly used to display process information that is being transmitted to a control room or control system. The display is either analog with pointer and scale or a digital LCD. Their purpose is to provide easy-to-read process values for maintenance or troubleshooting the control system.

These field mounted indicators receive DC voltage or current signal inputs from electronic Transmitters and indicate process measurement values. They are available with Analog or Digital displays. Both accept 4-20 mA DC input. The MLA also accepts 10-50Ma DC and 1-5 VDC. Mounting options are Horizontal or Vertical Pipe mounting.

 
 
  Specifications :  
 
green_line
 
space
MLA Series
Input Resistance: < 6.5 ohm (MLA 4-20mA),
< 13.5 ohm (MLA 10-50mA),
~4K ohm (MLA 1-5V)
Voltage Drop: 1.8V typ., 2V max. (MLD)
Scale: Black. Analog single graduations 0- 100% standard.
Accuracy: ± 1.5% of full scale (MLA)
Operating Temperature Range: -20 to 60°C
Vibration: 1G @ 10-150Hz
Insulation Resistance: Between input terminals and case 100 Mohm at 500 V DC
Dielectric Strength: Between input terminals and case:
1000 VAC for 1 minute.
Mounting: Nominal 2” (50mm) pipe mount or surface.
Electrical Classification: NEMA4X, FM, CSA, EXPLOSIONPROOF CL1, DIV1, GPS A,B,C,D, DUST-IGNITIONPROOF CLII / III, GPS E,F,G
Case and Cover:

Die cast aluminum, baked polyurethane paint.
Dark green; NEMA 4X

Electrical Connection: NPT
Weight:

3.0 lbs

MLD Series
Voltage Drop: 1.8V typ., 2V max. (MLD)
Scale: Digital 0-100.0% w/decimal standard.
Accuracy: ± 0.05% of full scale (1999) +1 digit
Operating Temperature Range: 0 to 60°C
Temperature drift: ±0.3digit/°C
Vibration: 3G @ 10-150Hz (MLD)
Insulation Resistance: Between input terminals and case 100 Mohm at 500 V DC
Dielectric Strength: Between input terminals and case:
1000 VAC for 1 minute.
Mounting: Nominal 2” (50mm) pipe mount or surface.
Electrical Classification: NEMA4X, FM, CSA, EXPLOSIONPROOF CL1, DIV1, GPS A,B,C,D, DUST-IGNITIONPROOF CLII / III, GPS E,F,G
Case and Cover:

Die cast aluminum, baked polyurethane paint.
Dark green; NEMA 4X

Electrical Connection: NPT
Weight: 2.7 lbs
 
 