- 60Hz and 100Hz Cab Filters
- All Pass position bypasses Cab Filters
|
|
|
| |
| |
|
|
|
| |
|
|
The Model 2003 also includes all of the features of the Model 2000 with the addition of Cab Filters. The Model 2003 was designed for rapid transit / commuter type railroads using 60Hz and 100Hz coding systems.
|
|
| |
| |
|
|
| |
|
| |
| |
- 2000 Series Enhanced Features
Auto-polarity on all DC functions with red NEG indicator. Ohmmeter Voltage Mode detects foreign voltage of either polarity. Multi-turn Ohmmeter Adjust for more accurate setting of Ohmmeter zero. Power saving sleep feature prevents draining of the batteries if accidentally left on. Dry contact requires no adjustment to measure relay contact on time. Measures rate directly without counting pointer swings. Can detect and hold 2 msec momentary closures. Selectable DC Amps Polarity (Auto, Positive, Negative). Will measure pulse code transmit and receive currents independently.
- Direct Measurement of Code Parameters
Directly measures code parameters in any AC or DC range. No counting of pointer swings or adjustments are necessary. Peak Follow allows downward adjustment of peak levels.
- Accurately measures code parameters to 420 cpm.
- CAB Filter Options (2001,2002, & 2003)
Allow measurements of all code parameters for selected cab frequencies without shutting down equipment. Active in all AC Volts and AC Amps Ranges.
- Safety Features
Shrouded safety jacks and spring-loaded shroud on test lead plugs. Fused on all ranges and functions except 6A and 30A. Battery/Lamp Test and Battery Monitor prevent false readings from weak batteries.
- Mechanical Features
Rugged, lightweight, weather-resistant case. Secondary protective window (field replaceable). Modular construction for easier repair and upgrade. One Year Warranty on construction and calibration.
|
|
| |
| |
|
|
| |
|
| |
|
| DC Voltage |
|
| Ranges: |
0.6, 3, 15, 60, and 300 VDC. |
| Accuracy: |
± 1.5% of Full Scale |
| Sensitivity: |
1000 ohms per volt. |
| AC Voltage |
|
| Ranges: |
1.5, 3, 15, 150, 300, and 600 VAC |
| Accuracy: |
± 3.0% of full scale. |
| Sensitivity: |
288 ohms per volt. |
| Calibration: |
Average responding, RMS calibrated. |
| Frequency Response: |
25Hz to 400Hz. |
| DC Current (mA) |
|
| Ranges: |
15, 60, and 300 mA DC.
|
| Accuracy: |
± 1.5% of Full Scale |
| Sensitivity: |
60 mV nominal. |
| DC Current |
|
| Ranges: |
1.5, 6, and 30 Amps DC.
|
| Accuracy: |
± 1.5% of Full Scale |
| Sensitivity: |
60 mV nominal. |
| AC Current |
|
| Ranges: |
1.5, 6, and 30 Amps AC. |
| Accuracy: |
± 3.0% of full scale. |
| Burdern (Volts) : |
60 mV nominal. |
| Calibration: |
Average responding, RMS calibrated. |
| Frequency Response: |
25Hz to 400Hz. |
| Resistance |
|
| Ranges: |
R x 1 and R x 100 |
| Center scale: |
5 and 500 ohms |
| Accuracy: |
± 2% of scale length ± 0.5 ohms |
| Open Circuit Voltage |
1.0 to 1.8 VDC |
| Voltage Sense Mode: |
| Range: |
15 V AC or DC |
| Accuracy: |
± 20% Typical |
| Sensitivity: |
1000 ohms per volt |
| CAB Filter Response
(AC Ranges)
|
60Hz Filter: 57 to 64Hz
100Hz Filter: 92 to 100Hz
All filters introduce an additional ± 1.5% level error. |
| Code Functions
(AC Ranges)
|
| On Time: |
| Ranges: |
3% to 100%
|
| Accuracy: |
±3.0% of full scale |
| Rate: |
| Ranges: |
30 to 500 CPM
|
| Accuracy: |
±3.0% of full scale |
| Peak Hold: |
| Captures and holds highest level peak.
|
| Peak Follow: |
| Displays all peaks > 25% of previous peaks. |
| Dry Contact
|
| On Time: |
| Ranges: |
0 to 100%
|
| Accuracy: |
±2.0% of full scale |
| Rate: |
| Ranges: |
30 to 500 CPM
|
| Accuracy: |
±3.0% of full scale |
| Peak Hold: |
| Pointer will deflect to full scale and remain there with a 2.0 millisecond or longer contact closure
|
| Allowable Contact Resistance : |
0 to 100 ohms |
| Test Voltage : |
7.5 to 15 VDC |
| Test Current: |
830 A max. |
| Meter Movement
|
| Electrical : |
100 A ± 1% at full scale |
| Construction: |
Taut band, shock mounted, 100 degree deflection, critically damped, Mirrored Scale, Bar-ring magnet. |
| General
|
| Dimensions: |
5.0" wide x 6.5" high x 3.2" deep |
| Weight: |
Approx. 2.75 lbs., Approx. 4.75 lbs. w/case and leads. |
| Batteries: |
Two, 9 volt alkaline (NEDA 1604) One, 1.5 volt alkaline D-cell (NEDA 13F) |
| Battery Life: |
320 hours typical, 2000 hours in Sleep Mode |
|
|
| |
| |
|
|
|
|
| |
| |
Not Available |
|
|
|
|
|
 |
|
|
|
|