- 25 Range
- 6 DC Voltage Ranges
- 5 AC Voltage Ranges
- 4 DC Current Ranges
- 5 Resistance Ranges
- 5 Decibel Ranges
- Mirrored Scale
- The Model 630's glass window and black thermoset plastic case resists damage from abrasion, hot soldering irons and many solvents.
- Diode overload protection and 2 fuse arrangement.
- Single range switch and only one set of input jacks to minimize error.
- Completely insulated unit with safety leads.
|
|
|
 |
| |
|
|
| |
|
Single range switch minimizes error. 25 ranges up to 1200VAC or DC; 6DC/5AC volt ranges, 5 DC current ranges, 4 AC output voltage measurement, 4 decibel ranges and 4 ohm ranges to 100MW. 10-amp DC current, with no external shunt required. Includes 48" leads, alligator clips, batteries, fuses and instructions.
|
|
|
| |
| |
|
|
| |
|
| |
|
| DC Voltage |
|
| Ranges: |
0.3 (16,667 Ohms/Volt) 3, 12, 60, 300, 600 (20,000 Ohms/Volt) |
| Accuracy: |
± 1.5% of Scale Length |
| AC Voltage |
|
| Ranges: |
3, 12, 60, 300, 600 (5,000 Ohms per Volt) |
| Accuracy: |
± 3% of Full Scale |
| DC Current (Milliamperes) |
|
| Ranges: |
0.06, 1.2, 12, 120 |
| Accuracy: |
± 1.5% of Full Scale |
| Max. Voltage Burden: |
300mV |
| |
|
| Decibels: |
-20dBm to +57dBm (1mW, 600 Ohms) |
| Resistance |
|
| Ranges: |
1K Ohms, 10K Ohms, 100K Ohms, 1M Ohms, 100M Ohms (200 Ohms center scale on lowest range) |
| Mid-Scale: |
4.4 Ohms on lowest range |
| Accuracy: |
± 1.5% of Scale Length |
| General |
|
| Decibles: |
-20dBm to +57dBm (1mW, 600 Ohms) |
| Meter & Scale: |
Taut-band movement, mirrored scale. |
| Overload Protection : |
Meter movement is diode protected. 1 Amp/250V, & 2 Amp/600 Volt circuit fuses |
| Dimensions: |
3 11/32" x 5.5" x 7.5"
85mm x 140mm x 190mm |
| Weight: |
5 Lbs. (2.25kg) |
| Batteries: |
(1) 30V NEDA 210
(1) 1.5V NEDA 13F |
| Accessories : |
48" safety test leads, screw-on insulated alligator clips, batteries, spare 1A fuse and instruction manual |
|
|
| |
| |
|
|
|
|
| |
| |
 |
|
|