- 58 Ranges
- 14 DC Voltage Ranges
- 10 AC Voltage Ranges
- 12 DC Current Ranges
- 6 Resistance Ranges
- 8 Decibel Ranges
- Polarity-reversing switch
- Range doubling switch
- Mirrored Scale
- Single range switch to minimize error
- Thermoset plastic case with plastic window
|
|
|
 |
| |
|
|
| |
|
Single range switch minimizes error. 58 ranges up to 1020VAC or DC; 6DC/5AC volt ranges, 5 DC current ranges, 4 AC output voltage measurement, 4 decibel ranges and 4 ohm ranges to 100MW. 10-amp DC current, with no external shunt required. Includes 48" leads, alligator clips, batteries, fuses and instructions.
|
|
|
| |
| |
|
|
| |
|
| |
|
| DC Voltage |
|
| Ranges: |
0-0.120 at 60uA, 0.240 at 120uA, 0.3, 1.5, 6, 30, 150, 600 (20,000 Ohms/Volt), 0-0.6, 3, 12, 60, 300, 1200 (10,000 Ohms/Volt) |
| Accuracy: |
± 1.5% of Full Scale |
| Sensitivity: |
10,000 Ohms/Volt |
| AC Voltage |
|
| Ranges: |
0-1.5, 6, 30, 150, 600, (10,000 Ohms/Volt), 0-3, 12, 60, 300, 1200 (5,000 Ohms/Volt) |
| Accuracy: |
± 3% of Full Scale |
| Sensitivity: |
5,000 Ohms/Volt |
| DC Current |
|
| Ranges: |
60uA, 600uA, 6mA, 60mA, 600mA, 6A, 120 A, 1.2mA, 12mA, 120mA, 1.2A, 12A |
| Accuracy: |
± 1.5% of Full Scale |
| Max. Voltage Drop: |
500mV |
| |
|
| Decibels: |
-26dBm to +51dBm (0dBm at 1mW on a 600 Ohms line) |
| Resistance |
|
| Ranges: |
0-20K Ohms, 200K Ohms, 2M Ohms, 20M Ohms (200 Ohms center scale on lowest range) |
| Accuracy: |
± 1.5% of Scale Length |
| AC Output |
|
| Ranges: |
1.5, 6, 30, 150 (10,000 Ohms/Volt), 3, 12, 60, 300 (5,000 Ohms/Volt) |
| General |
|
| Meter & Scale: |
50uA taut-band movement. 4.5" mirrored scale. Temperature compensation. All range polarity-reversing switch. Slide switch for range doubling. |
| Overload Protection : |
Meter movement is diode protected. 1 Amp/250V, & 2 Amp/600 Volt circuit fuses |
| Dimensions: |
3 11/32" x 5.5" x 7.5"
85mm x 140mm x 190mm |
| Weight: |
5 Lbs. (2.25kg) |
| Batteries: |
(1) 30V NEDA 210
(1) 1.5V NEDA 13F |
| Accessories : |
48" safety test leads, screw-on insulated alligator clips, batteries, spare 1.25 Amp and 12 Amp fuses and instruction manual. |
|
|
| |
| |
|
|
|
|
| |
| |
 |
|
|