- 58 Ranges
- 14 DC Voltage Ranges
- 10 AC Voltage Ranges
- 10 DC Current Ranges
- 6 Resistance Ranges
- 10 AC Output Voltage Measurement Ranges
- 8 Decibel Ranges
- Polarity Reversing Switch
- Mirrored Scale
- Range Doubling Switch
|
|
|
 |
| |
|
|
| |
|
|
| One of the best models available. Drop resistant, high impact case guaranteed to withstand a 5 foot drop. Mirrored scale to reduce parallax error. Polarity reversing switch. Meter movement 50uA; 4-1/2" taut band. Dimensions: 3.3" x 5.3" x 7.3". Test leads and batteries included. |
|
|
| |
| |
|
|
| |
|
| |
|
| DC Voltage |
|
| Ranges: |
0-0.15, 0.5, 1.5, 15, 50, 150, 500
@
(20,000 Ohms/Volt)
0-0.3, 1, 3, 30, 100, 300, 1000
@
(10,000 Ohms/Volt) |
| Accuracy: |
± 1.5% of Full Scale |
| AC Voltage |
|
| Ranges: |
0-1.5, 15, 50, 150, 500 @(10,000 Ohms/Volt),
0-3, 30, 100, 300, 100 @(5,000 Ohms/Volt) |
| Accuracy: |
± 3% of Full Scale |
| DC Current |
|
| Ranges: |
0.05, .1, 1, 5, 10, 50, 100, 500, 1000
|
| Accuracy: |
± 1.5% of Full Scale |
| Max. Voltage Drop: |
1V |
| |
|
| Decibels: |
-26dBm to +52dBm (0dBm at 1mW on a 600 Ohms line) |
| Resistance |
|
| Ranges: |
0-1K Ohms, 10K Ohms, 100K Ohms, 1M Ohms, 10M Ohms, 100M Ohms |
| Center scale: |
6 Ohms lowest range |
| Accuracy: |
± 1.5% of Scale Length |
| General |
|
| Meter & Scale: |
Meter movement is diode protected. 1/8 Amp/250V, 1 Amp/250V |
| Overload Protection : |
Taut Band type. 4.5" mirrored scale, temperature compensation, single range switch, all range polarity reversing switch, range doubling switch. |
| Confidence Test: |
Built-in reassurance check of instrument meter. |
| Dimensions: |
3 1/4" x 5 1/4" x 7 1/4"
83mm x 133mm x 184mm |
| Weight: |
4 lbs. (1.75kg) |
| Case: |
High-impact thermoplastic, Gray |
| Batteries: |
(1) 30V NEDA #210
(1) 1.5V NEDA 13F |
| Accessories : |
48" safety test leads, screw-on insulated alligator clips, batteries, spare 1/8A and 1A fuses and instruction manual. |
|
|
| |
| |
|
|
|
|
| |
| |
 |
|
|