Triplett HR Series, Analog Panel Meters

Characteristics :

  • Sizes: 1 1/2", 2 1/2", 3 1/2"
  • Pivot & Jewel or Taut band suspension
  • Accuracy: ±2% DC;
    ±2% AC- iron vane
  •  ± 3% AC - rectifier type
    (60 Hz sinewave)
  • Repeatability: ± 2%
    Pivot & Jewel AC & DC,
  • 0.5% Taut Band DC Only;
    ± 2% iron vane
 
 
  Product Description:  
space
green_line
 

 

The HR Series is a ruggedized water resistant panel meter. Its high shock, dust resistant meter and robust pivot and jewel meter is ideal for extreme environmental applications.

 
 
  Specifications :  
 
green_line
 
space
Display
Scaling: Customized to any scaling desired, from linear to specialized Cos Ø, square root distributions, with color applications for visual emphasis and to any desired engineering units.
Specific accuracies
Basic Accuracy: ±2.0% of full scale basic accuracy class.
Rectifier Type Meters: ±3% of full scale basic accuracy class.
Repeatability: ±2% for Pivot and Jewell
±0.5% for taut Band
 
Position of use: Vertical (scale) standard
or to specified angle or position
Full scale deflection: 90 °
Movement: Taut Band
The absence of friction resulting from this permits greater sensitivities and provides more rugged meters.Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots.
Pivot and Jewel
In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for high vibration environments because of the mechanism’s inherent stability and strength. Accuracy and repeatability are almost equal to the taut-band’s, and good performance from the pivot and jewel construction is the reason for its long popularity.
Case: thermoplastic front, steel, sealed back
Mounting: 4 stud (1 1/2), 3 stud (2 1/2, 3 1/2)
Overload Capacity:

1 second

1000% on AC and DC Current
0-100V 1000% on AC and DC Voltage
101 - up 200% on AC and DC Voltage
Continous
150% on AC and DC Current
120% on DC and AC Voltage
OverShoot:

20% Maximum for DC
30% Maximum for AC

Response time: Above 50µA-1.5 sec. max.
below 50µA - 3 sec, max.
General:
Operating Temp.: 0 to 40°C (32 to 104°F)
Storage Temp: -10 to 50°C (14 to 50°F)
Relative Humidity: 95% (non condensing)
 
 