- Tamper-Resistant Front Panel Design
- Simple Menu Control
- Electronic dwell settings
- Electronic ramping
- No load setup of trip current and output voltage
- Optional Continuity test mode
- LED Display With Meter Memory
- Output voltage fine adjustment
- Software calibration control
- Line and load regulation
- Flashing high voltage indicator
|
|
|
| |
| |
|
|
|
| |
|

|
The 2515 is a 500 VA (5 KV, 100 mA AC) rated Hipot tester that allows manufacturers to satisfy requirements for high current Hipot tests. It features an LED display, menu driven parameter control, electronic ramp and dwell, and a memory for parameter storage. An optional ground continuity check feature is available. |
|
|
| |
| |
|
|
| |
|
| |
|
| Input |
| Voltage: |
115 / 230 selectable
+/- 15% variation, 47 – 63Hz |
| Fuse: |
115 VAC, 230VAC -- 3.15A fast acting 250VAC |
| Output Voltage: |
Rating = 0 – 5000VAC, 100mA
Regulation = +/- 1% of output + 5V |
| Voltage Setting: |
Rating = 0V – 5.00KV, 10 volts/step
Accuracy = +/- 2% of Setting + 5V (relative to display output)
Can be adjusted during operation |
| Dwell Time Setting: |
0 = Continuous
1 = One Second Test
60 = Sixty Second Test |
| Ramp Time Setting: |
Setting = 0 and 0.2 - 999.9 seconds
Resolution = 0.1 Second/Step
0 ramp setting = 0.1 seconds fixed ramp |
| Failure Setting: |
High Limit = 0.1-100.0mA,0.1mA/step
Accuracy = +/- 2% of set + .05mA |
| Metering |
Voltmeter (4 digits)
Range = AC 0.00 – 5.00KV
Resolution = 0.01KV
Accuracy = +/- 2% of read +10V |
Ammeter (4 digits)
Range = AC 0.00 - 100.0 mA
Resolution = 0.01 mA
Accuracy = +/- 2% of read + 0.05 mA |
| Timer Display: |
Range = 0.0 - 999.9 seconds
Resolution = 0.1 second
Accuracy = +/- 0.2% of reading + 0.05 seconds |
| Ground Continuity Check: |
Current: DC 0.1A +/- 0.01A, fixed
Max. Ground Resistance: 1 ohm +/- 0.1ohm, fixed |
|
|
| |
| GENERAL SPECIFICATIONS |
| Remote Control |
Test start input through a 9-pin D-type connector. |
| Line Cord |
Detachable 7 ft (2.13 m) power cable terminated
in a three-prong grounding plug |
| Terminations |
6ft. (1.52m) high voltage safety retracting probe,
6ft. (1.52m)
high voltage clip probe and 6ft. (1.82m) return clip lead. |
| Dimension |
(W x H x D) 17.00 x 5.75 x 11.75 in.
430 x 133 x 300 mm |
| Weight |
62 Lbs (29 Kgs) |
|
| |
| |
|
|
|
|
| |
| |
General Specifications |
|
|
|
|
|
 |
|
|
|
|
General Information
Remote Control
The following inputs and outputs are available through a 9-pin D type connector on the back panel.
Inputs:
Test, Reset, Safety Interlock
Outputs:
Pass, Fail, Processing
Terminations
6' (1.52m) High Voltage safety retracting probe and 6' (1.52m) high voltage clip probe with 6' (1.52m) return clip lead.
Mechanical
Bench or rack mount with tilt up front feet.
Dimension
WxHxD)
17.0 x 5.25 x 11.75 in.
(430 x 133 x 300 mm)
Weight: 62 lbs. (29 Kgs)
|
|
| |
| |
|
|