Spacer Home Contact_us ob Opportunities ISO_Registration Privacy_Statement
 
Caption_Header
Slaughter
2512 Series
AC Hipot Testers
 
previous URL Next URL
< Links >
 
 
green_line
 
 

Slaughter  2512 Series  500 VA Hipot Testers

 Characteristics:

green_line
 
  • Tamper-Resistant Front Panel Design
  • Simple Menu Control
  • Electronic dwell settings
  • Electronic ramping
  • No load setup of trip current and output voltage
  • Optional Continuity test mode
  • Test Storage
  • LED Display With Meter Memory
  • Output voltage fine adjustment
  • Software calibration control
  • Line and load regulation
  • 12. PLC remote inputs and outputs
  • Flashing high voltage indicator
 
 
  Product Description:  
space
green_line
 

space

The 2512 is a 250 VA (2.5 KV, 100 mA AC) rated Hipot tester that allows manufacturers to satisfy requirements for high current Hipot tests without reaching the higher voltage range found in 500 VA instruments. It features an LED display, menu driven parameter control, electronic ramp and dwell, and a memory for parameter storage. An optional ground continuity check feature is available

 
 
  Specifications :  
 
green_line
 
Input
Voltage: 115 / 230 selectable
+/- 15% variation, 47 – 63Hz
Fuse: 115 VAC, 230VAC -- 3.15A fast acting 250VAC
Output Voltage: Rating = 0 – 2500VAC, 100mA
Regulation = +/- 1% of output + 5V
Voltage Setting: Rating = 0V – 2.50KV, 10 volts/step Accuracy = +/- 2% of Setting + 5V (relative to display output) Can be adjusted during operation
Dwell Time Setting: 0 = Continuous
1 = One Second Test
60 = Sixty Second Test
Ramp Time Setting: Setting = 0 and 0.2 - 999.9 seconds
Resolution = 0.1 Second/Step
0 ramp setting = 0.1 seconds fixed ramp
Failure Setting: High Limit = 0.1-100.0mA, 0.1mA/step
Accuracy = +/- 2% of set + .05mA
Metering Voltmeter (4 digits)
Range = AC 0.00 – 2.50KV
Resolution = 0.01KV
Accuracy = +/- 2% of read +10V
Ammeter (4 digits)
Range = AC 0.00 - 100.0 mA
Resolution = 0.01 mA
Accuracy = +/- 2% of read + 0.05 mA
Timer Display: Range = 0.0 - 999.9 seconds
Resolution = 0.1 second
Accuracy = +/- 0.2% of reading + 0.05 seconds
Ground Continuity Check: Current: DC 0.1A +/- 0.01A, fixed
Max. Ground Resistance: 1 ohm +/- 0.1ohm, fixed
 
 
GENERAL SPECIFICATIONS
Remote Control

Inputs: Test & Reset;
Outputs: Pass, Fail & Test in Process

Line Cord Detachable 7 ft (2.13 m) power cable terminated
in a three-prong grounding plug
Terminations 6ft. (1.52m) high voltage safety retracting probe,
6ft. (1.52m)
high voltage clip probe and 6ft. (1.82m) return clip lead.
Dimension (W x H x D) 17.00 x 5.75 x 11.75 in.
430 x 133 x 300 mm
Weight 44 Lbs (20 Kgs)
 
  Downloads:  
space
green_line
 
  pdf_pic Downloads: General Specifications  
base

General Information

Remote Control
The following inputs and outputs are available through a 9-pin D type connector on the back panel.

Inputs:
Test, Reset, Safety Interlock
Outputs:
Pass, Fail, Processing

Terminations
6' (1.52m) High Voltage safety retracting probe and 6' (1.52m) high voltage clip probe with 6' (1.52m) return clip lead.

Mechanical
Bench or rack mount with tilt up front feet.

Dimension
WxHxD)
17.0 x 5.25 x 11.75 in.
(430 x 133 x 300 mm)

Weight: 44 lbs. (20 Kgs)

 

 

 
 