- Tamper-Resistant Front Panel Design
- Simple Menu Control
- Electronic dwell settings
- Electronic ramping
- No load setup of trip current and output voltage
- Test Storage
- Optional Continuity test mode
- LED Display With Meter Memory
- Output voltage fine adjustment
- Software calibration control
- Line and load regulation
- PLC remote inputs and outputs
- Flashing high voltage indicator
|
|
|
| |
| |
|
|
|
| |
|

|
The 2510 is a 5 KV, 10 mA AC Hipot tester that is designed for production line AC Hipot testing. With its advanced features and product reliability it is well suited for quick and easy production line safety testing. |
|
|
| |
| |
|
|
| |
|
| |
|
| Input |
| Voltage: |
115 / 230 selectable
+/- 15% variation, 47 – 63Hz |
| Fuse: |
115 VAC, 230 VAC - 2A fast acting 250 VAC |
| Output Voltage: |
Rating = 0 – 5000VAC
Regulation = +/- 1% of output + 5V |
| Voltage Setting: |
Rating = 0.01KV – 5.00KV, 10 volts/step
Accuracy = +/- 2% of Setting + 5V (relative to display output)
Can be adjusted during operation |
| Dwell Time Setting: |
0 = Continuous
1 = One Second Test
60 = Sixty Second Test |
| Ramp Time Setting: |
Setting = 0 and 0.2 - 999.9 seconds
Resolution = 0.1 Second/Step
0 ramp setting = 0.1 seconds fixed ramp |
| Failure Setting: |
High Limit = 0.00-10.00mA,0.01mA/step
Accuracy = +/- 2% of set + .02mA |
| Metering |
Voltmeter (4 digits)
Range = AC 0.00 – 5.00KV
Resolution = 0.01KV
Accuracy = +/- 2% of read +10V |
Ammeter (4 digits)
Range = AC 0.00 - 10.00 mA
Resolution = 0.01 mA
Accuracy = +/- 2% of read + 0.02 mA |
| Timer Display: |
Range = 0.0 - 999.9 seconds
Resolution = 0.1 second
Accuracy = +/- 0.1% of reading + 0.05 seconds |
| Ground Continuity Check: |
Current: DC 0.1A +/- 0.01A, fixed
Max. Ground Resistance: 1 ohm +/- 0.1ohm, fixed |
|
|
| |
| GENERAL SPECIFICATIONS |
| Remote Control |
The following input and output signals are provided through the 9-pinD type connector;
1. Remote Control: Test, Reset and Safety Interlock
2. Outputs: Pass, Fail and Test in Process |
| Line Cord |
Detachable 7 ft (2.13 m) power cable terminated
in a three-prong grounding plug |
| Terminations |
HV Safety Retracting Probe with 6 ft. (1.82m) Lead. HV Clip with
6 ft. (1.82m) Lead.
Ground Return Clip with 6 ft. (1.82m) Lead. |
| Dimension |
(W x H X D) 4.75” x 5.75” x 14.5”
(120 x 146 x 370 mm) |
| Weight |
16.0 lbs. (7.25 Kgs) |
|
| |
| |
|
|
|
|
| |
| |
General Specifications |
|
|
|
|
|
 |
|
|
|
|
General Information
Remote Control
The following inputs and outputs are available through a 9-pin D type connector on the back panel.
Inputs:
Test, Reset, Safety Interlock
Outputs:
Pass, Fail, Processing
Terminations
High Voltage (Alden) and Ground Return (Banana) Sockets
Dimension
WxHxD)
( 4.75 x 5.75 x 14.50 in.
(120 x 146 x 370 mm)
Weight: 16 lbs. (7.25 Kgs)
|
|
| |
| |
|
|