- Hermetically Sealed Package
- ±0.25% FSO Static Accuracy
- 0-5” H2O through 0-5,000 psi
- Low Cost; Starting @ $725.00
- Analog or Switching Output
- Wet/Wet
- ±0.1% FSO Static Accuracy
- ±0.5% FSO Thermal Error Band
- Hasteloy or Inconel alt. materials
- Low power
|
|
|
 |
| |
|
|
| |
|
|
Senex’s EXD Series Differential Pressure Transmitter is designed and
approved for use in hazardous locations. The EXD’s entirely welded
316L SST construction is hermetically sealed making it ideal for the
worst of pressure applications. CSA/CUS Explosion Proof certified for
Class I Div 1 and Class I Div 2 Groups A, B, C, D.
Manufactured for extended life cycles
The EXD is built using advanced manufacturing techniques to ensure
symmetry between the Hi and Lo ports. Symmetry, along with automated
welding procedures and extreme environmental burn-in give Senex’s
differrential pressure products excellent performance and reliability over
time and at high elevated line pressure.
Entirely welded 316L SST pressure cavities
The EXD’s pressure ports all welded 316L SST ‘O’-Ring free design
makes it ideal for high cyclical applications, capillary filled systems, or
applications wsere a guaranteed lieak freee system is needed.
Alternate materials for service in corrosive environments
For corrosive environments where 316L is not the material of choice, the
EXD is available in Hasteloy C276, C22 or Inconel 718. |
|
|
| |
| |
|
|
| |
|
| |
|
| Electrical |
|
EXD1
EXD2 & EXD3
EXD4 |
2-15 Vdc
8-38 Vdc*
10-30 Vdc |
| Output |
|
EXD1
EXD2
EXD3
EXD4 |
1-2 mV/V*
0-5 Vdc*
4-20 mAdc
DPDT Switch (1A @ 60 Vdc) |
| Zero Balance : |
±1% FSO |
| FSO Setting : |
±1% FSO |
| Resolution: |
Infinite (±0.001% FSO usable) |
Response Time
EXD1
EXD2 & EXD3 |
< 50mS
< 100 mS |
| Insulation Resistance: |
1000 MO @ 50 Vdc
|
| Reverse Polarity: |
Protected |
| Power Supply Effect: |
±.002% FSO per V input |
| EMI/RFI: |
Internal Filtering (EXD2 and EXD3) |
| Short Circuit : |
Protected Up to 40 Vdc |
| Certification |
|
CSA/CUS Explosion Proof Class I Div 1 Groups A, B, C, D
CSA/CUS Explosion Proof Class I Div 2 Groups A, B, C, D
Master Contract Number: 229278
Certificate Number: 1658325 |
| Performance |
|
| Static Accuracy: |
±0.25% FSO* (BFSL, RSS)
(combined effects of non-linearity, hysteresis &repeatability) |
| Static Pressure Effect: |
On zero ±15% FSO per 1,000 psi
On span ±1% of reading per 1,000 psi |
| Repeatability : |
±0.1% FSO
|
| Temperature Effects : |
±1.5% FSO over comp range
(combined effects of Zero & FSO with reference at 70 oF)
|
| Long Term Stabily: |
±0.25% FSO per year |
| Environmental |
|
| Compensated Temp Range: |
0 to 170 °F
|
| Operating Temp Range: |
-40 to 200 °F
|
| Storage Temp Range: |
-40 to 250 °F |
| Mechanical |
|
| Pressure Ranges: |
Range a:0-5” H2O through 0-30 psi
Range b:0-30 through 0-200 psid
Range c:0-300 through 0-1k psid
Range d:0-2k through 0-5 k psid
(Customer may specify any range/eng. unit FOC) |
| Line Pressure: |
Range a:1,000 psi
Range b:1,000 psi
Range c:3,000 psi
Range d:5,000 psi |
| Burst Pressure: |
Range a:Minimum 3k psi
Range b:Minimum 5k psi
Range c:Minimum 10k psi
Range d:Minimum 12k psi |
| Proof Pressure: |
Range a:1000 psi
All other:3X Full Scale either side
(7k psi max)* |
Materials: Wetted Parts:
Non-wetted Parts: |
Wetted Parts 316L SST
316L SST plus electrical connector |
| Pressure Port: |
¼”-NPT Female*
|
| Electrical Connector : |
1/2”NPT Male conduit cable exit with
24” cable |
| Weight: |
18 oz nominal |
|
|
| |
| |
|
|
|
|
| |
| |
 |
|
|
|
|
|
 |
|
|
|
|