| Insulation Ranges |
| Test Voltages : |
(BMM2000): 250, 500, 1000 V |
| (BMM2080): 50, 100, 250, 500, 1000 V |
| Measuring Range: |
(BMM 2000) 0,01 MΩ to 20 GΩ |
| (BMM 2080) 0,01 MΩ to 200 GΩ |
| (0 - 100 GΩ on analog scale ) |
| Test voltage accuracy: |
+15% maximum on open circuit |
| Test Current on load: |
1mA at min. pass value of insulation specified in BS7671, HD384 and IEC 364, 2 mA max.
|
| Accuracy: |
±2% ±2 digits ±0.2% per GΩ |
| Continuity |
| Measuring Range: |
0,01 Ω to 99,9 Ω (0 to 10 Ω on analog scale) |
| Accuracy: |
±2% ±2 digits |
| Open circuit voltage: |
5 V ±1V |
| Test current: |
210 mA ±10 mA (0 - 2 Ω) |
| Buzzer: |
Operates continuously at less than 5 Ω |
| Resistance |
| Measuring Range: |
0,01 kΩ to 9,99 MΩ (0 to 100 MΩ on analog scale) with Auto Ranging or Range Lock Facility. |
| Accuracy: |
± 3% ± 2 digits |
| Open circuit voltage: |
5 V ±1V |
| Short circuit current |
25 μA ± 5 μA |
| Voltage |
| Measuring Range: |
±1V to ±500 V (0 to 1000 V on analog scale) |
| Accuracy: |
0 to 500 V d.c. or a.c. (50/60 Hz) ±2% ±3 digit
0 to 500 V a.c. (400 Hz) ±5% ±3 digits |
| Millivolts |
| Measuring Range: |
±0,1 mV to 1 ±999 mV
(0 to 1000 mV on analog scale) |
| Accuracy: |
10 mV to 1999 mV d.c. or a.c (50/60 Hz)
±2% ±3 digit
0,1 mV to 10 mV d.c. or a.c. (50/60 Hz)
±2% ±5 digits
10 mV to 1999 mV a.c. (16-460 Hz)
±5% ±3 digit
0,1 mV to 10 mV a.c. (16-460 Hz)
±5% ±5 digits
d.c. millivolts zeroing: Up to 9,9 mV |
| Transducer Compatibility |
| Virtually any mV output transducer may be connected to facilitate measurements of other parameters such as temperature, humidity etc. A unique transducer offset adjustment ensures is included. |
| Capacitance (BMM2080) |
| Measuring Range: |
0,1 nF to 9,99 |
| Accuracy: |
±3% ±0,2 nF ±2 digits uF zeroing: Up to 10 nF |
| Milliamperes |
| Measuring Range: |
0,1 mA to 500 mA (0 to 1000 mA on analog scale) |
| Accuracy: |
10 mA to 1999 mA d.c. or a.c.
(50/60 Hz)
±2% ±3 digit 0,1 mA to 10 mA d.c. or a.c. (50/60 Hz)
±2% ±5 digits
10 mA to 1999 mA a.c. (16-460 Hz)
±5% ±3 digits
0,1 mA to 10 mA a.c. (16-460 Hz)
±5% ±5 digits |
| Frequency |
| Measuring Range: |
16 Hz to 460 Hz |
| Accuracy: |
±1% ±1 digit |
| Power Supply |
| Battery Type:: |
6 x 1,5 V Alkaline cells IEC LR6 type |
| Battery Life: |
Typically 3000, 5 second 1 kV tests |
| General |
| Backlight |
User selectable LED backlight with auto turn off to save battery life |
| Test Result Storage |
Up to 99 Distribution Board References each with up to 99 Circuit References may be specified. Test Results may be stored against any circuit and distribution board combination. Data may be recalled to the display, printed or downloaded to PowerSuite for Windows or NICEone software |
| Communications |
RS232 9 pin male D connector. Baud rate 9600 |
| Printer Output |
Prints test results, distribution board and circuit details to external serial print |