- W, VA, VAR, kWH and power factor measurement even on distorted waveforms
- AC/DC current up to 2000 Amps
- True RMS, peak, crest factor, total harmonic distortion, distortion factor, frequency measurement, and dc ripple
- 3 phase power capability
- Live harmonic analysis, bar graph display
- Simultaneous display of multiple parameters plus waveform and chart displays
- Internal logging of five parameters with 5000 readings
- Real-time logging or download to optional PowerLog software
|
|
| |
| |
|
|
| |
|
The Megger DCM2000P Power Clampmeter combines the functionality of power meter, oscilloscope, harmonics meter and data logger in one easy to use package. The design meets the requirements of BSEN 61010-1 600V Cat IV for supply side applications. A large backlit dot matrix LCD clearly displays waveforms, harmonics, chart trends and up to five parameters at a time. The DCM2000P can measure dc, ac, pulsed and mixed currents up to 2000 A, voltages up to 600 V, all power related parameters including energy consumption, frequency, crest factor, total harmonic distortion, distortion factor and ripple. It features auto ranging and auto-zeroing and has a built-in three-phase adapter for power measurements.
This battery-operated precision power meter can transmit both stored and live measurements to a PC running AVO PowerLog software for further analysis if required. The DCM2000P is ideally suited to measure mains power quality and applications in the development, installation, maintenance and repair of equipment and devices used in power electronics and power engineering. It simplifies the compensation of reactive power, even for complex waveforms with high harmonic distortion.
Data Logging
The DCM 2000P may be used to perform data logging to its internal non-volatile memory , or in real time to a serially connected PC running the optional PowerLog software. In PC mode data is continually sent to the PC and is not stored in the instruments memory. All the parameters shown on the display are logged. When internal logging is selected, up to 5000 readings may be stored, (2500 sets of two or 1000 sets of 5 parameters). The maximum logging period is the determined by the memory capacity and the battery life, (24hrs in this mode). A chart display screen is also available to show the variation of single parameter during the logging period. |
|
| |
| |
|
|
|
| |
| Current Measurement |
| Ranges (auto) |
40/400/2000 A |
| Accuracy |
±1.5% rdg. ±5 dgts |
| Resoluition |
0.01/0.1/1 A |
| Voltage Measurement |
| Ranges (auto) |
4/40/400/600 V |
| Accuracy |
±1% rdg. ±5 dgts |
| Resoluition |
0.001/0.01/0.1/1 V |
| kW/kVA/kVAR Measurement |
kW/kVA/kVAR Ranges
(autoranging) |
4/40/400/1200 kW/kVA/kVAR |
| Accuracy |
±2.5% rdg. ±5 dgts |
| Resoluition |
0.001/0.01/0.1/1 kW |
| kWHr |
| Ranges (auto) |
|
| Accuracy |
±3% rdg. ±5 dgts |
| Resoluition |
0.001/0.01/0.1/1/10 kWHr |
| Frequency |
|
| Ranges |
4,40,400,4000, 40,000 kWHr |
| Accuracy |
0.5% rdg (40-70Hz) |
| Frequency |
0.1Hz |
| Crest Factor |
|
| Ranges |
10 Hz-1 kHz |
| Accuracy |
±3% rdg.±5 dgts (CF1-3) |
| Frequency |
0.01 |
| Total Harmonic Distortion |
| Range |
1-5 |
| Resolution |
±3% rdg.±5 dgts |
| Accuracy |
0.1% |
|
| |
| |
|
|
|
| |
| |
| Power Supply |
1x9 V alkaline battery, IEC 6-LF22
Continuous battery life
Typically 12 hours
AutoPower Off feature |
| Length: |
|
| Depth: |
98mm (3.75 inches) |
| Height: |
52mm (2 inches) |
| Weight |
(including batteries): 820g (1.8lbs) |
| Jaw Opening |
60mm ø |
| Safety |
IEC 1010-1-1992 EN 61010-1 1992-09 safety Requirements for
electrical equipment for measurement, control, and laboratory
use.
Part 2-032: 1994-12 Particular Requirements for hand-held current
clamps for electrical measurement and test.
Part 2-031 1993-02 Particular Requirements for hand-held probe
assemblies for electrical measurement and test
600V Cat IV (750V CatIII) Pollution Degree 2. |
|
| |
| |
|
|
|
|
| |
| |
 |
|
|